← Back
Elevator apt, fireproof without stores
BEDFORD AVENUE
BROOKLYN · BIN 3428969
💬 Discuss this project
2022Year Built
8Stories
D3Building Class
R7AZoning
23,758 sfGross Floor Area
32Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Elevator apt, fireproof without stores · Owner of record: 952 BEDFORD LLC · 5,000 sf lot · 4.75 FAR built · Flood zone X
Locations of Work
StructuralMechanicalPlumbingFire Protection
Roof6p · 3 filings · 20 docs
Bulkhead1p · 1 filing · 2 docs
Floor 83p · 3 filings · 20 docs
Floor 74p · 2 filings · 20 docs
Floor 63p · 3 filings · 20 docs
Floor 52p · 2 filings · 20 docs
Floor 43p · 2 filings · 20 docs
Floor 32p · 2 filings · 20 docs
Floor 25p · 3 filings · 20 docs
Floor 12p · 2 filings · 20 docs
Cellar4p · 4 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
DORIA407/08/2026
OWNERS REP703/22/2026
952 BEDFORD1803/22/2026
MORGAN SERVICES GROUP COR103/22/2026
B B GLOBAL DEVELOPMENT203/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/25/2020$2.7M—— → —— not available
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CAVALRY2103/21/2026
GREEN STUDIO203/21/2026
AE DESIGN SOLUTION803/21/2026
CAVALRY ASSOCIATES COM303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TIGER BUILDING CONSTR LLCGeneral Contractor3207/08/2026
CORE SCAFFOLD SYSTEMS INC.General Contractor603/21/2026
BRUCHE MECHANICAL NY LLCFire Protection307/08/2026
JAMES CHUNElectrical203/21/2026
PLBG P & H INCPlumbing207/08/2026
FASA CONTRACTING INCGeneral Contractor103/22/2026
V. VASS ELECTRIC CORPElectrical103/22/2026
VILLAGE ELECTL CONTRS INC 004467General Contractor103/22/2026
DORIA, INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
M. INT'L ENGINEERING PLLC31291005/20/2025
SKYLINE RIGGING7880106/05/2023
CHUN ENGINEERING CONSULTA9605109/06/2022
Building Lifecycle
All (159)Filed (18)Permit Issued (23)Signed Off (10)Violation (11)Inspection (9)Objection (58)Special Inspection (30)
08/06/2025
Signed off — Alteration
MECHANICAL FILING IN CONJUNCTION WITH NB APPLICATION 340754945. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
B00698442-I1
07/14/2025
Special inspection requirement — HVAC-R and service water heating equipment
JAMES CHUN
07/14/2025
Special inspection requirement — Mechanical Systems
JAMES CHUN
07/14/2025
Special inspection requirement — Energy Code Compliance Inspections
JAMES CHUN
07/14/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
JAMES CHUN
07/14/2025
Special inspection requirement — HVAC-R and service water heating system controls
JAMES CHUN
07/14/2025
Special inspection requirement — Final
CLOUD LEE
07/03/2025
Objection resolved — Addressed
05/30/2025
Objection raised — Admin
05/20/2025
Filed — Alteration
MECHANICAL FILING IN CONJUNCTION WITH NB APPLICATION 340754945. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
B00698442-P2
04/30/2025
Special inspection requirement — Energy Code Compliance Inspections
NANIK MASSAND
04/30/2025
Special inspection requirement — Final
NANIK MASSAND
04/30/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
NANIK MASSAND
04/30/2025
Special inspection requirement — HVAC-R and service water heating equipment
NANIK MASSAND
04/30/2025
Special inspection requirement — HVAC-R and service water heating system controls
NANIK MASSAND
04/30/2025
Special inspection requirement — Mechanical Systems
NANIK MASSAND
10/09/2024
Signed off — Alteration
B00885300-I1
05/07/2024
Signed off — Alteration
PLUMBING/ SPRINKLER IN CONJUNCTION WITH NB APPLICATION # 340754945. PL: INSTALLATION OF NEW SANITARY, VENT, STORM, WATER SYSTEMS. SPRINKLER : FURNISHING AND INSTALLING COMPLETE SPRINKLER SYSTEM. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B00712279-I1
05/02/2024
Signed off — Alteration
STRUCTURAL APPLICATION IN CONJUNCTION WITH NEW BUILDING APPLICATION 340754945.
B00698437-I1
04/19/2024
Permit issued — Sprinklers
B00712279-I1-EW-SP
04/19/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
NANIK MASSAND
04/19/2024
Special inspection requirement — HVAC-R and service water heating system controls
NANIK MASSAND
04/19/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
NANIK MASSAND
04/19/2024
Special inspection requirement — Maintenance information
NANIK MASSAND
04/19/2024
Special inspection requirement — HVAC-R and service water heating equipment
NANIK MASSAND
04/19/2024
Special inspection requirement — Energy Code Compliance Inspections
NANIK MASSAND
04/19/2024
Special inspection requirement — Sprinkler Systems
NANIK MASSAND
04/17/2024
Filed — Alteration
PLUMBING/ SPRINKLER IN CONJUNCTION WITH NB APPLICATION # 340754945. PL: INSTALLATION OF NEW SANITARY, VENT, STORM, WATER SYSTEMS. SPRINKLER : FURNISHING AND INSTALLING COMPLETE SPRINKLER SYSTEM. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B00712279-P4
04/16/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
NANIK MASSAND
04/16/2024
Special inspection requirement — Sprinkler Systems
NANIK MASSAND
04/16/2024
Special inspection requirement — Energy Code Compliance Inspections
NANIK MASSAND
04/16/2024
Special inspection requirement — HVAC-R and service water heating equipment
NANIK MASSAND
04/16/2024
Special inspection requirement — HVAC-R and service water heating system controls
NANIK MASSAND
04/16/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
NANIK MASSAND
04/16/2024
Special inspection requirement — Maintenance information
NANIK MASSAND
03/06/2024
Signed off — Alteration
TEMPORARY CONSTRUCTION FENCE IN CONJUNCTION WITH NB FILING, 340754945.
B00712037-I1
02/22/2024
Permit issued — Construction Fence
B00712037-I1-FN
02/05/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
02/01/2024
Inspection — Certified Sprinkler (SP) - Booster Pump Test
Certified
View inspection ↗
02/01/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
01/30/2024
Permit issued — Mechanical Systems
B00698442-I1-MS
01/30/2024
Permit issued — Structural
B00698437-I1-ST
12/20/2023
Signed off — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00823416-I1
12/20/2023
Signed off — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00823509-I1
10/12/2023
Filed — Alteration
PLUMBING/ SPRINKLER IN CONJUNCTION WITH NB APPLICATION # 340754945. PL: INSTALLATION OF NEW SANITARY, VENT, STORM, WATER SYSTEMS. SPRINKLER : FURNISHING AND INSTALLING COMPLETE SPRINKLER SYSTEM. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B00712279-P3
10/10/2023
Special inspection requirement — Sprinkler Systems
NANIK MASSAND
10/10/2023
Special inspection requirement — HVAC-R and service water heating equipment
NANIK MASSAND
10/10/2023
Special inspection requirement — Maintenance information
NANIK MASSAND
10/10/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
NANIK MASSAND
09/22/2023
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
09/08/2023
Filed — Alteration
PLUMBING/ SPRINKLER IN CONJUNCTION WITH NB APPLICATION # 340754945. PL: INSTALLATION OF NEW SANITARY, VENT, STORM, WATER SYSTEMS. SPRINKLER : FURNISHING AND INSTALLING COMPLETE SPRINKLER SYSTEM. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B00712279-P1
08/15/2023
Permit issued — Mechanical Systems
B00698442-I1-MS
08/02/2023
Signed off — Alteration
FOUNDATION APPLICATION IN CONJUNCTION WITH NB APPLICATION 340754945.
B00744647-I1
07/10/2023
Filed — Alteration
MECHANICAL FILING IN CONJUNCTION WITH NB APPLICATION 340754945. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
B00698442-P1
06/26/2023
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
06/26/2023
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
06/26/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/26/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
06/06/2023
Permit issued — Protection and Mechanical Methods
B00885300-I1-PMM
06/05/2023
Filed — Alteration
B00885300-I1
Latest 60 of 159 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersSigned-offBRUCHE MECHANICAL NY LLC04/19/2024
DOB NOWConstruction FenceSigned-offTIGER BUILDING CONSTR LLC02/22/2024
DOB NOWMechanical SystemsSigned-offTIGER BUILDING CONSTR LLC01/30/2024
DOB NOWStructuralSigned-offTIGER BUILDING CONSTR LLC01/30/2024
DOB NOWMechanical SystemsSigned-offTIGER BUILDING CONSTR LLC08/15/2023
DOB NOWProtection and Mechanical MethodsSigned-offDORIA, INC06/06/2023
DOB NOWConstruction FenceSigned-offTIGER BUILDING CONSTR LLC05/09/2023
DOB NOWPlumbingSigned-offPLBG P & H INC03/03/2023
DOB NOWSprinklersSigned-offBRUCHE MECHANICAL NY LLC03/03/2023
DOB NOWSupported ScaffoldSigned-offCORE SCAFFOLD SYSTEMS INC02/04/2023
DOB NOWSidewalk ShedSigned-offCORE SCAFFOLD SYSTEMS INC02/04/2023
DOB NOWSprinklersSigned-offPLBG P & H INC01/17/2023
DOB NOWPlumbingSigned-offBRUCHE MECHANICAL NY LLC01/17/2023
DOB NOWStructuralSigned-offTIGER BUILDING CONSTR LLC12/30/2022
DOB NOWFoundationSigned-offTIGER BUILDING CONSTR LLC06/02/2022
DOB NOWSupport of ExcavationSigned-offTIGER BUILDING CONSTR LLC05/31/2022
DOB NOWConstruction FenceSigned-offTIGER BUILDING CONSTR LLC05/11/2022
DOB NOWSupport of ExcavationPermit IssuedTIGER BUILDING CONSTR LLC04/28/2022
DOB NOWFoundationPermit IssuedTIGER BUILDING CONSTR LLC04/27/2022
DOB NOWConstruction FencePermit IssuedTIGER BUILDING CONSTR LLC01/28/2022
DOB NOWConstruction FencePermit IssuedTIGER BUILDING CONSTR LLC12/31/2021
DOB NOWConstruction FencePermit IssuedTIGER BUILDING CONSTR LLC12/18/2020
DOB NOWConstruction FencePermit IssuedTIGER BUILDING CONSTR LLC09/22/2020
BIS—ISSUEDTIGER BUILDING CONSTR LLC01/29/2024
BIS—ISSUEDTIGER BUILDING CONSTR LLC03/07/2023
BIS—ISSUEDTIGER BUILDING CONSTR LLC01/05/2023
BIS—ISSUEDTIGER BUILDING CONSTR LLC04/05/2022
BIS—RE-ISSUEDTIGER BUILDING CONSTR LLC03/17/2022
BIS—ISSUEDOWNERS GC NY LLC01/04/2022
BIS—ISSUEDOWNERS GC NY LLC09/17/2021
BISOTISSUEDTIGER BUILDING CONSTR LLC01/25/2021
4 projects · most recent 04/10/2025
General Wiring
FiledStatusContractorScope
04/10/2025CompleteVILLAGE ELECTL CONTRS INCGeneral Wiring
11/20/2023CompleteNET POWER ELECTRIC CORPGeneral Wiring
02/03/2023CompleteSOLAS ELECTRICAL CORP—
08/19/2020CompleteV. VASS ELECTRIC CORP—
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
02/05/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
02/01/2024Certified Sprinkler (SP) - Booster Pump TestCertifiedView ↗
02/01/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
09/22/2023Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
06/26/2023Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
06/26/2023Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
06/26/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/26/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
03/10/2023Pass-Final CND-Occupancy InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 60
DateRequirementInspectorRole
07/14/2025HVAC-R and service water heating equipmentJAMES CHUNenergy_progress
07/14/2025Mechanical SystemsJAMES CHUNspecial
07/14/2025Energy Code Compliance InspectionsJAMES CHUNprogress
07/14/2025HVAC-R and service water piping design and insulationJAMES CHUNenergy_progress
07/14/2025HVAC-R and service water heating system controlsJAMES CHUNenergy_progress
07/14/2025FinalCLOUD LEEprogress
04/30/2025Energy Code Compliance InspectionsNANIK MASSANDprogress
04/30/2025FinalNANIK MASSANDprogress
04/30/2025HVAC-R and service water piping design and insulationNANIK MASSANDenergy_progress
04/30/2025HVAC-R and service water heating equipmentNANIK MASSANDenergy_progress
04/30/2025HVAC-R and service water heating system controlsNANIK MASSANDenergy_progress
04/30/2025Mechanical SystemsNANIK MASSANDspecial
04/19/2024Fire-Resistant Penetrations and JointsNANIK MASSANDspecial
04/19/2024HVAC-R and service water heating system controlsNANIK MASSANDenergy_progress
04/19/2024HVAC-R and service water piping design and insulationNANIK MASSANDenergy_progress
04/19/2024Maintenance informationNANIK MASSANDenergy_progress
04/19/2024HVAC-R and service water heating equipmentNANIK MASSANDenergy_progress
04/19/2024Energy Code Compliance InspectionsNANIK MASSANDprogress
04/19/2024Sprinkler SystemsNANIK MASSANDspecial
04/16/2024Fire-Resistant Penetrations and JointsNANIK MASSANDspecial
04/16/2024Sprinkler SystemsNANIK MASSANDspecial
04/16/2024Energy Code Compliance InspectionsNANIK MASSANDprogress
04/16/2024HVAC-R and service water heating equipmentNANIK MASSANDenergy_progress
04/16/2024HVAC-R and service water heating system controlsNANIK MASSANDenergy_progress
04/16/2024HVAC-R and service water piping design and insulationNANIK MASSANDenergy_progress
Latest 25 of 60.
▾Documents — 335 on file (BIS + DOB NOW)
▸Plans & Drawings15
▸DOB NOWPlans/Sketch13
08/30/2026B00712037-I1Request digital key ↗
08/29/2026B00737120-P1Request digital key ↗
08/29/2026B00737120-I1Request digital key ↗
Showing 3 of 13 on file for this type
▸DOB NOWPlans/Sketch - Sidewalk Shed1
09/02/2026B00389153-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Supported Scaffold1
09/02/2026B00389153-I1Request digital key ↗
▸Applications & Permits67
▸BISPLAN / WORK APPROVAL APPLICATION58
04/29/2025340754945Open ↗
03/17/2025340754945Open ↗
12/24/2024340754945Open ↗
Showing 3 of 58 on file for this type
▸BISWORK PERMIT APPLICATION6
03/09/2023340754945Open ↗
04/11/2022340754945Open ↗
03/23/2022340754945Open ↗
Showing 3 of 6 on file for this type
▸BISBPP-5 - Authorization to the Department of Transportation3
07/07/2023340764818Open ↗
05/25/2021340764818Open ↗
05/25/2021340764818Open ↗
▸Zoning, Tax Lot & Property Records10
▸BISZONING DIAGRAM5
04/04/2024340754945Open ↗
04/27/2021340754945Open ↗
Showing 2 of 5 on file for this type
▸BISTAX LOT: FINAL LOT NUMBER ISSUED1
03/14/2022340754945Open ↗
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
06/07/2022340754945Open ↗
▸BISVERIFY TAX LOT1
10/01/2025340754945Open ↗
▸BISADDRESS: NEW HOUSE NUMBER APPROVED1
06/07/2022340754945Open ↗
▸BISCO OBJ: VERIFY ADDRESS-TOPO STAMP1
04/19/2021340754945Open ↗
▸Seals & Professional Certifications47
▸DOB NOWProgress Inspector Seal & Signature16
09/23/2026B00712279-P1Open ↗
09/01/2026B00712279-P3Open ↗
09/01/2026B00712279-P3Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature14
08/30/2026B00712037-I1Open ↗
08/29/2026B00737120-I1Open ↗
08/29/2026B00737120-P1Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature11
09/23/2026B00712279-P1Open ↗
09/01/2026B00712279-P3Open ↗
08/29/2026B00712279-I1Open ↗
Showing 3 of 11 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISAPPLICANT OWNER SIGNATURE2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Trade Schedules & Equipment5
▸BISDEP SANITARY SEWER CERTIFICATION (HCP/SCP)2
10/01/2025340754945Open ↗
Showing 1 of 2 on file for this type
▸BISHVAC & SERVICE WATER HEATING EQUIPMENT1
05/01/2024340754945Open ↗
▸BISHVAC & SERVICE WATER HEATING SYSTEM CONTROLS1
05/01/2024340754945Open ↗
▸BISDEP STORMWATER SEWER CERTIFICATION (HCP/SCP)1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Safety & Tenant Protection9
▸BISSTREET TREE CHECKLIST6
12/05/2022340754945Open ↗
09/02/2022340764818Open ↗
04/13/2022340754945Open ↗
Showing 3 of 6 on file for this type
▸BISSTREET TREES: RECEIPT OF STREET TREES SITE PLAN1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISBPP: STREET TREES SITE PLAN1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWTenant Protection Plan1
08/13/2026B00389153-I1Open ↗
▸Energy Compliance19
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY8
06/22/2023340754945Open ↗
08/15/2022340754945Open ↗
07/20/2022340754945Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWEN2: As Built Energy Analysis2
08/13/2026B00698442-I1Open ↗
08/13/2026B00712279-I1Open ↗
▸BISINTERIOR LIGHTING POWER1
05/01/2024340754945Open ↗
▸BISFENESTRATION U-FACTOR & PRODUCT RATING1
05/01/2024340754945Open ↗
▸BISFENESTRATION AREAS1
05/01/2024340754945Open ↗
▸BISINSULATION PLACEMENT & R VALUES1
05/01/2024340754945Open ↗
▸BISLIGHTING IN DWELLING UNITS1
05/01/2024340754945Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
05/01/2024340754945Open ↗
▸BISELECTRIC MOTORS1
05/01/2024340754945Open ↗
▸BISLIGHTING CONTROLS1
05/01/2024340754945Open ↗
▸DOB NOWPreliminary Commissioning Report Certification1
08/13/2026B00698442-I1Open ↗
▸Inspections & Test Reports23
▸BISTECHNICAL REPORT: RESPONSIBILITY9
08/15/2022340754945Open ↗
09/14/2021340754945Open ↗
05/12/2021340754945Open ↗
Showing 3 of 9 on file for this type
▸BISTECHNICAL REPORT: SOIL INSPECTION3
11/23/2021340754945Open ↗
Showing 1 of 3 on file for this type
▸BISTR3: CONCRETE DESIGN MIX TECHNICAL REPORT1
01/30/2025340754945Open ↗
▸BISSTRUCTURAL STABILITY - ALTERATIONS OF EXISTING BUILDINGS1
05/01/2024340754945Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
05/01/2024340754945Open ↗
▸BISFIRE-RESISTIVE RATED CONSTRUCTION1
05/01/2024340754945Open ↗
▸BISFOOTING AND FOUNDATION INSPECTION1
05/01/2024340754945Open ↗
▸BISPOST-INSTALLED ANCHORS1
05/01/2024340754945Open ↗
▸BISSUBGRADE INSP / SOILS-SITE PREP1
05/01/2024340754945Open ↗
▸BISSOIL REPORT1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWSOIL REPORT1
08/29/2026B00744647-I1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/29/2026B00744647-I1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/29/2026B00744647-I1Open ↗
▸Approvals, Objections & Sign-offs39
▸BISSCHEDULE A - OCCUPANCY / USE33
04/29/2025340754945Open ↗
03/17/2025340754945Open ↗
12/24/2024340754945Open ↗
Showing 3 of 33 on file for this type
▸BISSUPERSEDING LETTER3
08/13/2025340754945Open ↗
04/11/2022340754945Open ↗
03/23/2022340754945Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION2
04/13/2022340754945Open ↗
10/14/2021340754945Open ↗
▸BISUPDATED HPD APPROVAL DOCUMENT1
05/21/2024340754945Open ↗
▸Cost, Insurance & Ownership4
▸BISPROJECT-SPECIFIC GL INSURANCE3
03/09/2023340754945Open ↗
01/05/2022340754945Open ↗
09/17/2021340754945Open ↗
▸BISCOST AFFIDAVIT1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Filing & Intake Forms56
▸BISADDITIONAL INFORMATION51
10/08/2025340754945Open ↗
08/13/2025340754945Open ↗
06/18/2025340754945Open ↗
Showing 3 of 51 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
09/02/2022340764818Open ↗
▸BISEFILING COVER SHEET1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Other Documents18
▸BISPLOT DIAGRAM5
11/23/2022340754945Open ↗
06/07/2022340754945Open ↗
04/12/2022340754945Open ↗
Showing 3 of 5 on file for this type
▸BISSUSTAINABLE ROOF ZONE FORM2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION2
01/30/2025340754945Open ↗
09/10/2021340754945Open ↗
▸BISSHUTOFF DAMPERS1
05/01/2024340754945Open ↗
▸BISBPP: PHOTOS-SIGNED/SEALED BY APPLICANT1
09/02/2022340764818Open ↗
▸BISTRASH COMPACTOR REQUIREMENTS1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISMAINTENANCE INFORMATION1
05/01/2024340754945Open ↗
▸BISRECORDS MGMT FEE PAYMENT RECEIPT1
07/26/2022340764818Open ↗
▸BISHVAC & SERVICE WATER PIPING DESIGN AND INSULATION1
05/01/2024340754945Open ↗
▸BISPERMANENT CERTIFICATE1
05/01/2024340754945Open ↗
▸BISDUCT DESIGN, INSULATION AND LEAKAGE TESTING1
05/01/2024340754945Open ↗
▸DOB NOWAdjoining Owners Notification1