← Back
Zoned residential, not Manhattan
CASTLETON AVENUE
STATEN ISLAND · BIN 5862737
💬 Discuss this project
0Year Built
—Stories
V0Building Class
R3AZoning
0 sfGross Floor Area
0Units
2 Open Violations 1 unresolved · 1 paperwork only ▸FDNY Report ↗
Zoned residential, not Manhattan · Owner of record: 126 CASTLETON AV PROPERTY LLC · 4,174 sf lot · 0 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction1p · 1 filing · 20 docs
Floor 2Under Construction1p · 1 filing · 20 docs
Floor 1Under Construction6p · 1 filing · 20 docs
CellarUnder Construction1p · 1 filing · 20 docs
BasementUnder Construction1p · 1 filing · 20 docs
1 job · most recent 03/31/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
03/31/2026Permit IssuedMAXIMUM CONTRACTING INCHeating and Air Conditioning Systems
Heat / Cool
Gree basement: Gree Model #FXE60HP230V1R32AH Attic: Gree Model #FXE36HY230V1R32AH 2 tons · Fan Coil Indoor ×2
1 job · most recent 03/31/2026
Sprinkler System
FiledStatusContractorScope
03/31/2026——Sprinkler System
1 job · most recent 03/31/2026
Plumbing-Sprinkler Storm Water/Sanitary
FiledStatusContractorScope
03/31/2026Permit IssuedPREMIER PL,HTG & MECH INCPlumbing-Sprinkler, Storm, Water/Sanitary
1 job · most recent 09/04/2025
General Wiring
FiledStatusContractorScope
09/04/2025CompleteRIDGE ELECTRIC CORP.General Wiring
1 job · most recent 03/31/2026
Concrete
FiledStatusContractorScope
03/31/2026Permit IssuedMAXIMUM CONTRACTING INCConcrete
1 job · most recent 03/31/2026
Fence
FiledStatusContractorScope
03/31/2026Permit IssuedMAXIMUM CONTRACTING INCFence
Building Lifecycle
All (84)Filed (7)Permit Issued (6)Violation (4)Inspection (9)Objection (28)Special Inspection (30)
09/22/2026
Permit issued — Mechanical Systems
S01177132-S5-MS
07/01/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/20/2026
Special inspection requirement — Air barrier - visual inspection
Daniel Ryan
06/20/2026
Special inspection requirement — Metering
Daniel Ryan
06/20/2026
Special inspection requirement — Interior lighting power
Daniel Ryan
06/20/2026
Special inspection requirement — Fenestration air leakage
Daniel Ryan
06/20/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Daniel Ryan
06/20/2026
Special inspection requirement — Fenestration areas
Daniel Ryan
06/20/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Daniel Ryan
06/20/2026
Special inspection requirement — Wood – Prefabricated I-Joists
Daniel Ryan
06/20/2026
Special inspection requirement — Subgrade Inspections
Daniel Ryan
06/20/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Daniel Ryan
06/20/2026
Special inspection requirement — Concrete - Cast-In-Place
Daniel Ryan
06/20/2026
Special inspection requirement — Final
Daniel Ryan
06/20/2026
Special inspection requirement — Fire-Resistance Rated Construction
Daniel Ryan
06/20/2026
Special inspection requirement — Footing and Foundation
Daniel Ryan
06/20/2026
Special inspection requirement — Energy Code Compliance Inspections
Daniel Ryan
06/20/2026
Special inspection requirement — Permanent certificate
Daniel Ryan
06/20/2026
Special inspection requirement — Insulation placement and R values
Daniel Ryan
06/20/2026
Special inspection requirement — Maintenance information
Daniel Ryan
06/20/2026
Special inspection requirement — Protection of exposed foundation insulation
Daniel Ryan
06/20/2026
Special inspection requirement — Electric vehicle service equipment requirements
Daniel Ryan
06/20/2026
Special inspection requirement — Air barrier — testing
Daniel Ryan
04/07/2026
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
04/07/2026
Special inspection requirement — Maintenance information
Daniel Ryan
04/03/2026
Objection raised — Energy
04/03/2026
Objection raised — Structural
03/31/2026
Filed — New Building
CURB CUT 17'
S01177132-P2
03/31/2026
Filed — New Building
CURB CUT 17'
S01177132-P1
03/30/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Daniel Ryan
03/30/2026
Special inspection requirement — Energy Code Compliance Inspections
Daniel Ryan
03/30/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Daniel Ryan
03/30/2026
Special inspection requirement — HVAC-R and service water heating equipment
Daniel Ryan
03/30/2026
Special inspection requirement — Maintenance information
Daniel Ryan
03/30/2026
Special inspection requirement — HVAC-R and service water heating system controls
Daniel Ryan
03/04/2026
Filed — New Building
CURB CUT 17'
S01177132-S5
03/02/2026
Special inspection requirement — Final
03/02/2026
Special inspection requirement — Mechanical Systems
Daniel Ryan
02/24/2026
Violation issued (ECB, open)
Construction
02/24/2026
Violation issued (ECB, open)
Construction
01/27/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
01/27/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/21/2025
Inspection — Certified Sprinkler (PL)-Sprinkler-Hydro
Certified
View inspection ↗
11/21/2025
Inspection — Certified Sprinkler (PL) - SP - Roughing
Certified
View inspection ↗
11/18/2025
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
11/07/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
11/07/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
10/30/2025
Permit issued — Plumbing
S01177132-S2-PL
10/22/2025
Objection resolved — Addressed
10/20/2025
Objection raised — Admin
10/08/2025
Objection resolved — Addressed
10/08/2025
Objection resolved — Addressed
10/08/2025
Objection resolved — Addressed
10/08/2025
Objection resolved — Addressed
10/07/2025
Objection raised — Plumbing
10/07/2025
Objection raised — Plumbing
10/07/2025
Objection raised — Plumbing
10/07/2025
Objection raised — Plumbing
09/22/2025
Filed — New Building
CURB CUT 17'
S01177132-S2
09/20/2025
Filed — New Building
CURB CUT 17'
S01177132-S1
Latest 60 of 84 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
125 BROOK ST PROPERTY1809/23/2026
MAXIMUM CONTRACTING403/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
RYAN DESIGN ARCHITECTURE703/31/2026
CHEN CONSULTING ENGINEER, PLLC1—
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
APRILE BONAMO FILING REP103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MAXIMUM CONTRACTING INCGeneral Contractor509/23/2026
PREMIER PL,HTG & MECH INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
RYAN DESIGN ARCHITECTURE7159503/31/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedMAXIMUM CONTRACTING INC09/22/2026
DOB NOWPlumbingPermit IssuedPREMIER PL,HTG & MECH INC10/30/2025
DOB NOWFoundationPermit IssuedMAXIMUM CONTRACTING INC07/30/2025
DOB NOWFoundationPermit IssuedMAXIMUM CONTRACTING INC07/29/2025
DOB NOWFoundationPermit IssuedMAXIMUM CONTRACTING INC07/28/2025
DOB NOWConstruction FencePermit IssuedMAXIMUM CONTRACTING INC07/22/2025
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
07/01/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/07/2026Pass-Final PL - Up to 9 Requested FloorsPassView ↗
01/27/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/27/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/21/2025Certified Sprinkler (PL)-Sprinkler-HydroCertifiedView ↗
11/21/2025Certified Sprinkler (PL) - SP - RoughingCertifiedView ↗
11/18/2025Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
11/07/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
11/07/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 36
DateRequirementInspectorRole
06/20/2026Air barrier - visual inspectionDaniel Ryanenergy_progress
06/20/2026MeteringDaniel Ryanenergy_progress
06/20/2026Interior lighting powerDaniel Ryanenergy_progress
06/20/2026Fenestration air leakageDaniel Ryanenergy_progress
06/20/2026Fenestration and door U-factor and product ratingsDaniel Ryanenergy_progress
06/20/2026Fenestration areasDaniel Ryanenergy_progress
06/20/2026Subsurface Investigations (Borings/Test Pits)Daniel Ryanspecial
06/20/2026Wood – Prefabricated I-JoistsDaniel Ryanspecial
06/20/2026Subgrade InspectionsDaniel Ryanspecial
06/20/2026Fire-Resistant Penetrations and JointsDaniel Ryanspecial
06/20/2026Concrete - Cast-In-PlaceDaniel Ryanspecial
06/20/2026FinalDaniel Ryanprogress
06/20/2026Fire-Resistance Rated ConstructionDaniel Ryanprogress
06/20/2026Footing and FoundationDaniel Ryanprogress
06/20/2026Energy Code Compliance InspectionsDaniel Ryanprogress
06/20/2026Permanent certificateDaniel Ryanenergy_progress
06/20/2026Insulation placement and R valuesDaniel Ryanenergy_progress
06/20/2026Maintenance informationDaniel Ryanenergy_progress
06/20/2026Protection of exposed foundation insulationDaniel Ryanenergy_progress
06/20/2026Electric vehicle service equipment requirementsDaniel Ryanenergy_progress
06/20/2026Air barrier — testing Daniel Ryanenergy_progress
04/07/2026Maintenance informationDaniel Ryanenergy_progress
03/30/2026Fire-Resistant Penetrations and JointsDaniel Ryanspecial
03/30/2026Energy Code Compliance InspectionsDaniel Ryanprogress
03/30/2026HVAC-R and service water piping design and insulationDaniel Ryanenergy_progress
Latest 25 of 36.
▾Documents — 87 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/17/2026S01177132-I1Request digital key ↗
08/17/2026S01177132-S2Request digital key ↗
08/17/2026S01177132-S3Request digital key ↗
Showing 3 of 7 on file for this type
▸Applications & Permits6
▸BISBPP-5 - Authorization to the Department of Transportation3
06/23/2025540266406Open ↗
06/23/2025540266406Open ↗
09/19/2007510001837Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION2
02/28/2025540266406Open ↗
05/14/2007510001837Open ↗
▸BISBPP-16 - Application for waiver of curb alignment and/or sidewalk and curb1
05/23/2007510001837Open ↗
▸Zoning, Tax Lot & Property Records6
▸DOB NOWZD1: DOB Zoning Diagram2
08/17/2026S01177132-P2Open ↗
08/13/2026S01177132-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp2
08/17/2026S01177132-P2Open ↗
08/13/2026S01177132-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/17/2026S01177132-P2Open ↗
08/13/2026S01177132-I1Open ↗
▸Seals & Professional Certifications43
▸DOB NOWProgress Inspector Seal & Signature27
08/28/2026S01177132-I1Open ↗
08/28/2026S01177132-I1Open ↗
08/28/2026S01177132-I1Open ↗
Showing 3 of 27 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
08/28/2026S01177132-I1Open ↗
08/28/2026S01177132-I1Open ↗
08/28/2026S01177132-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/17/2026S01177132-P1Open ↗
08/17/2026S01177132-P2Open ↗
08/13/2026S01177132-S1Open ↗
Showing 3 of 7 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
02/28/2025540266406Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
02/28/2025540266406Open ↗
▸Trade Schedules & Equipment1
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/13/2026S01177132-I1Open ↗
▸Safety & Tenant Protection4
▸DOB NOWStreet Tree Checklist2
08/17/2026S01177132-P2Open ↗
08/13/2026S01177132-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026S01177132-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/17/2026S01177132-I1Open ↗
▸Environmental & Asbestos1
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
05/14/2007510001837Open ↗
▸Inspections & Test Reports6
▸BISBPP-9 - Request for Builders Pavement Field Inspection2
06/23/2025540266406Open ↗
09/19/2007510001837Open ↗
▸DOB NOWSOIL REPORT2
08/17/2026S01177132-P2Open ↗
08/13/2026S01177132-I1Open ↗
▸DOB NOWGeotechnical Report (BC 1803.6)1
08/13/2026S01177132-I1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026S01177132-I1Open ↗
▸Approvals, Objections & Sign-offs3
▸BISBPP-8 - Request Items for Builders Pavement Plan Signoff2
06/23/2025540266406Open ↗
09/19/2007510001837Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
05/14/2007510001837Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
02/28/2025540266406Open ↗
▸Other Documents9
▸BISBPP - SUPPORTING DOCUMENTATION2
06/23/2025540266406Open ↗
09/19/2007510001837Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/17/2026S01177132-P2Open ↗
08/13/2026S01177132-I1Open ↗
▸DOB NOWProperty Ownership Certification2
08/17/2026S01177132-P2Open ↗
08/13/2026S01177132-I1Open ↗
▸DOB NOWSite Survey: Initial2
08/17/2026S01177132-P2Open ↗
08/13/2026S01177132-I1Open ↗
▸BISBPP - DOT Builders Pavement Unit Waiver Request Form1
06/23/2025540266406Open ↗