← Back
Unlicensed parking lot
CONCOURSE VILLAGE EAST
BRONX · BIN 2130963
💬 Discuss this project
0Year Built
—Stories
G7Building Class
R8Zoning
0 sfGross Floor Area
0Units
Unlicensed parking lot · Owner of record: MORRISANIA DEVELOPMENT HOUSING DEVELOPME NT FUND CO · 25,133 sf lot · 0 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionCivilGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction27p · 4 filings · 20 docs
Floor 19Under Construction26p · 4 filings · 20 docs
Floor 18Under Construction23p · 4 filings · 20 docs
Floor 17Under Construction22p · 4 filings · 20 docs
Floor 16Under Construction22p · 4 filings · 20 docs
Floor 15Under Construction22p · 4 filings · 20 docs
Floor 14Under Construction22p · 4 filings · 20 docs
Floor 13Under Construction24p · 4 filings · 20 docs
Floor 12Under Construction24p · 4 filings · 20 docs
Floor 11Under Construction23p · 4 filings · 20 docs
Floor 10Under Construction24p · 4 filings · 20 docs
Floor 9Under Construction22p · 4 filings · 20 docs
Floor 8Under Construction22p · 4 filings · 20 docs
Floor 7Under Construction22p · 4 filings · 20 docs
Floor 6Under Construction22p · 4 filings · 20 docs
Floor 5Under Construction22p · 4 filings · 20 docs
Floor 4Under Construction22p · 4 filings · 20 docs
Floor 3Under Construction24p · 4 filings · 20 docs
Floor 2Under Construction109p · 3 filings · 20 docs
Floor 1Under Construction110p · 1 filing · 20 docs
CellarUnder Construction111p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
GLENCO CONTRACTING GROUP409/02/2026
GILBANE DEVELOPMENT2307/04/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/19/2025$16.9M—MORRISANIA DEVELOPMENT HOUSING DEVELOPMENT FUND CO → ICL 161 STREET BRONX HOUSING DEVELOPMENT FUND CORP— not available
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HOWARD I SHAPIRO ASSOCIATES203/21/2026
JM ZONING, LLC.1803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
GILBANE BUILDING COMPANYGeneral Contractor1408/26/2026
SPRING SCAFFOLDING LLCGeneral Contractor609/10/2026
GLENCO CONTRACTING GROUPGeneral Contractor309/02/2026
TT MECHANICAL CORPPlumbing307/08/2026
FLINT MECHANICAL CORPFire Protection107/08/2026
TTM GROUP CORPFire Protection105/29/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
EP INSPECTIONS AND COMMIS70791205/20/2026
Building Lifecycle
All (90)Filed (24)Permit Issued (29)Inspection (7)Special Inspection (30)
09/30/2026
Permit issued — Mechanical Systems
X00851840-S6-MS
09/09/2026
Filed — Alteration
INSTALLATION OF TEMPORARY GANTRY SYSTEM HOIST AS PER PLAN. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X01426409-S4
09/09/2026
Permit issued — Protection and Mechanical Methods
X01426409-S4-PMM
09/01/2026
Permit issued — Protection and Mechanical Methods
X01410600-I1-PMM
07/21/2026
Filed — Alteration
INSTALLATION OF TEMPORARY GANTRY SYSTEM HOIST AS PER PLAN. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X01426409-S3
07/21/2026
Permit issued — Protection and Mechanical Methods
X01426409-S3-PMM
07/21/2026
Permit issued — Sidewalk Shed
X01426409-I1-SH
07/20/2026
Permit issued — Protection and Mechanical Methods
X01426409-S2-PMM
07/16/2026
Filed — Alteration
INSTALLATION OF TEMPORARY GANTRY SYSTEM HOIST AS PER PLAN. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X01426409-I1
07/16/2026
Filed — Alteration
INSTALLATION OF TEMPORARY GANTRY SYSTEM HOIST AS PER PLAN. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X01426409-S2
07/16/2026
Filed — Alteration
INSTALLATION OF TEMPORARY GANTRY SYSTEM HOIST AS PER PLAN. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X01426409-S1
07/16/2026
Permit issued — Construction Fence
X01426409-S1-FN
07/10/2026
Permit issued — Protection and Mechanical Methods
X01413783-I1-PMM
07/07/2026
Filed — Alteration
Installation and use of temporary contractors shed/shanty as per plans filed herewith. This application is filed in conjunction with with NB X00851840-I1.
X01425191-I1
07/07/2026
Filed — Alteration
EQUIPMENT USE: DUAL 6559 # CAPACITY PERSONNEL HOIST DURING NB CONST, FILED SEP. HOIST SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION. ELEVATOR APPLICATION SUBMITTED SEPARATELY
X01422703-P1
07/07/2026
Permit issued — Protection and Mechanical Methods
X01425191-I1-PMM
07/02/2026
Permit issued — General Construction
X00851840-I1-GC
07/02/2026
Permit issued — Mechanical Systems
X00851840-S6-MS
07/01/2026
Permit issued — Support of Excavation
X00851840-S1-SE
06/29/2026
Filed — Alteration
EQUIPMENT USE: DUAL 6559 # CAPACITY PERSONNEL HOIST DURING NB CONST, FILED SEP. HOIST SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION. ELEVATOR APPLICATION SUBMITTED SEPARATELY
X01422703-I1
06/29/2026
Permit issued — Protection and Mechanical Methods
X01422703-I1-PMM
06/25/2026
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
06/23/2026
Permit issued — Construction Fence
X01324627-I1-FN
06/22/2026
Filed — Alteration
INSTALLATION AND USE OF TEMPORARY CONCRETE PLACING BOOM. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
X01413783-I1
06/22/2026
Filed — Alteration
INSTALLATION AND USE OF TEMPORARY EXTERIOR CLIMBING PLATFORMS AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X01410600-I1
06/22/2026
Filed — Alteration
INSTALLATION AND USE OF TEMPORARY LOADING PLATFORM AS PER PLANS HEREWITH. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X01413754-I1
06/22/2026
Permit issued — Protection and Mechanical Methods
X01413754-I1-PMM
06/17/2026
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
06/05/2026
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
05/26/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
EVAN PARGANOS
05/26/2026
Special inspection requirement — Post-installed Anchors
EVAN PARGANOS
05/26/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
EVAN PARGANOS
05/21/2026
Permit issued — General Construction
X00851840-I1-GC
05/20/2026
Filed — New Building
This NB application filed for 19 story R2, Supportive Housing. Project name - West Tower. Fee deferral letter is under Supporting Documents.
X00851840-P6
05/20/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
MOLLY GLENN
05/20/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
MOLLY GLENN
05/20/2026
Special inspection requirement — Post-installed Anchors
MOLLY GLENN
05/04/2026
Special inspection requirement — Protection of exposed foundation insulation
MOLLY GLENN
05/04/2026
Special inspection requirement — Vestibules
MOLLY GLENN
05/04/2026
Special inspection requirement — Metering
MOLLY GLENN
05/04/2026
Special inspection requirement — Energy Code Compliance Inspections
MOLLY GLENN
05/04/2026
Special inspection requirement — Lowest Floor Elevation
MOLLY GLENN
05/04/2026
Special inspection requirement — Interior lighting power
MOLLY GLENN
05/04/2026
Special inspection requirement — Lighting in dwelling units
MOLLY GLENN
05/04/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
MOLLY GLENN
05/04/2026
Special inspection requirement — Mastic and Intumescent Fire-resistant Coatings
MOLLY GLENN
05/04/2026
Special inspection requirement — Preliminary
MOLLY GLENN
05/04/2026
Special inspection requirement — Masonry
MOLLY GLENN
05/04/2026
Special inspection requirement — Concrete - Precast
MOLLY GLENN
05/04/2026
Special inspection requirement — Chimneys and vents
MOLLY GLENN
05/04/2026
Special inspection requirement — Post-installed Anchors
MOLLY GLENN
05/04/2026
Special inspection requirement — Sprayed fire-resistant materials
MOLLY GLENN
05/04/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
MOLLY GLENN
05/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
MOLLY GLENN
05/04/2026
Special inspection requirement — Wall Panels, Curtain Walls, and Veneers
MOLLY GLENN
05/04/2026
Special inspection requirement — Air barrier — testing
MOLLY GLENN
05/04/2026
Special inspection requirement — Electrical motors and elevators
MOLLY GLENN
05/04/2026
Special inspection requirement — Air barrier continuity plan testing
MOLLY GLENN
05/04/2026
Special inspection requirement — Subgrade Inspections
MOLLY GLENN
05/04/2026
Special inspection requirement — Concrete - Cast-In-Place
MOLLY GLENN
Latest 60 of 90 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedSC PRIME ENERGY LTD09/30/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedSPRING SCAFFOLDING LLC09/09/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedGLENCO CONTRACTING GROUP09/01/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedSPRING SCAFFOLDING LLC07/21/2026
DOB NOWSidewalk ShedPermit IssuedSPRING SCAFFOLDING LLC07/21/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedSPRING SCAFFOLDING LLC07/20/2026
DOB NOWConstruction FencePermit IssuedSPRING SCAFFOLDING LLC07/16/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedGLENCO CONTRACTING GROUP07/10/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedGILBANE BUILDING COMPANY07/07/2026
DOB NOWGeneral ConstructionPermit IssuedGILBANE BUILDING COMPANY07/02/2026
DOB NOWMechanical SystemsPermit IssuedGILBANE BUILDING COMPANY07/02/2026
DOB NOWSupport of ExcavationPermit IssuedGILBANE BUILDING COMPANY07/01/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedSPRING SCAFFOLDING LLC06/29/2026
DOB NOWConstruction FencePermit IssuedGILBANE BUILDING COMPANY06/23/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedGLENCO CONTRACTING GROUP06/22/2026
DOB NOWGeneral ConstructionPermit IssuedGILBANE BUILDING COMPANY05/21/2026
DOB NOWFoundationPermit IssuedGILBANE BUILDING COMPANY04/30/2026
DOB NOWStructuralPermit IssuedGILBANE BUILDING COMPANY04/30/2026
DOB NOWPlumbingPermit IssuedTT MECHANICAL CORP03/24/2026
DOB NOWSprinklersPermit IssuedTTM GROUP CORP01/20/2026
DOB NOWStandpipePermit IssuedTT MECHANICAL CORP01/20/2026
DOB NOWSprinklersPermit IssuedTT MECHANICAL CORP01/20/2026
DOB NOWGeneral ConstructionPermit IssuedGILBANE BUILDING COMPANY01/12/2026
DOB NOWStructuralPermit IssuedGILBANE BUILDING COMPANY12/22/2025
DOB NOWFoundationPermit IssuedGILBANE BUILDING COMPANY12/11/2025
DOB NOWSupport of ExcavationPermit IssuedGILBANE BUILDING COMPANY12/11/2025
DOB NOWMechanical SystemsPermit IssuedGILBANE BUILDING COMPANY12/10/2025
DOB NOWConstruction FencePermit IssuedGILBANE BUILDING COMPANY11/26/2025
DOB NOWStandpipePermit IssuedBLETSAS P&H CORP11/21/2025
1 project · most recent 05/20/2026
Air Conditioning Systems Heating and Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
05/20/2026Permit IssuedSC PRIME ENERGY LTDAir Conditioning Systems, Heating and Air Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Mitsubishi Electric PKA-A24KA8 24,000 BTU · Ductwork ×3
Heat / Cool
Mitsubishi Electric PURY-EP96TNU-A 96,000 BTU · Vrf Outdoor ×3
PEFY-P15NMAU-E4 15,000 BTU · Vrf Indoor ×2
PEFY-P30NMAU-E4 30,000 BTU · Vrf Indoor ×2
PLFY-P18NFMU-E4 18,000 BTU · Vrf Indoor ×2
PURY-EP192YNU-A 192,000 BTU · Vrf Outdoor ×2
PEFY-P48NMAU-E4 48,000 BTU · Vrf Indoor ×1
PLFY-P05NFMU-E 5,000 BTU · Vrf Indoor ×1
PLFY-P08NFMU-E 8,000 BTU · Vrf Indoor ×1
PLFY-P12NFMU-E 12,000 BTU · Vrf Indoor ×1
PURY-EP120TNU-A 120,000 BTU · Vrf Outdoor ×1
PURY-EP144YNU-A 144,000 BTU · Vrf Outdoor ×1
Heating
Indeeco 942U02000C, 926U02000CA 2 kW · Electric Heater ×2
926U05000CA 700 CFM · Electric Heater ×1
Ventilation
Swegon GOLD F RX 014 1,980 CFM · Erv ×3
GOLD F RX 035 4,180 CFM · Erv ×2
Ventacity VS3000 RTE 1,475 CFM · Erv ×2
VS400 CME 225 CFM · Erv ×1
VS900 CME 400 CFM · Erv ×1
Enervex MDVS50X/BEF500X, MCAS500X/BEF500X 3,520 CFM · Exhaust Fan ×2
Greenheck AX-72-190-0422-A50 10,624 CFM · Exhaust Fan ×2
1 project · most recent 05/20/2026
Sprinkler System
FiledStatusContractorScope
05/20/2026Permit IssuedTTM GROUP CORPSprinkler System
1 project · most recent 05/20/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
05/20/2026Permit IssuedTT MECHANICAL CORPGas, Storm, Water/Sanitary
6 projects · most recent 09/04/2026
General Wiring
FiledStatusContractorScope
09/04/2026Permit IssuedTEAM ELECTRIC, INCGeneral Wiring
08/11/2026Permit IssuedTEAM ELECTRIC, INC—
07/06/2026Permit IssuedTOP SHELF ELECTRIC CORP—
06/05/2026Permit IssuedTEAM ELECTRIC, INC—
05/07/2026Permit IssuedTEAM ELECTRIC, INCGeneral Wiring
04/29/2026Permit IssuedTEAM ELECTRIC, INC—
1 project · most recent 05/20/2026
Steel Concrete
FiledStatusContractorScope
05/20/2026Permit IssuedSC PRIME ENERGY LTDSteel, Concrete
2 projects · most recent 09/09/2026
Fence Sidewalk Shed
FiledStatusContractorScope
09/09/2026Permit IssuedSPRING SCAFFOLDING LLCFence, Sidewalk Shed
11/25/2025Permit IssuedGILBANE BUILDING COMPANYFence
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
06/25/2026Pass-Final PL - UndergroundPassView ↗
06/17/2026Pass-Final PL - UndergroundPassView ↗
06/05/2026Pass-Final PL - UndergroundPassView ↗
01/21/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/17/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/31/2025Pass-Final PL - UndergroundPassView ↗
07/17/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 128
DateRequirementInspectorRole
05/26/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationEVAN PARGANOSspecial
05/26/2026Post-installed AnchorsEVAN PARGANOSspecial
05/26/2026Fire-Resistant Penetrations and JointsEVAN PARGANOSspecial
05/20/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationMOLLY GLENNspecial
05/20/2026Post-installed AnchorsMOLLY GLENNspecial
05/20/2026Fire-Resistant Penetrations and JointsMOLLY GLENNspecial
05/04/2026Lowest Floor ElevationMOLLY GLENNprogress
05/04/2026Air barrier — testing MOLLY GLENNenergy_progress
05/04/2026Electrical motors and elevatorsMOLLY GLENNenergy_progress
05/04/2026Interior lighting powerMOLLY GLENNenergy_progress
05/04/2026VestibulesMOLLY GLENNenergy_progress
05/04/2026Air barrier continuity plan testingMOLLY GLENNenergy_progress
05/04/2026Fenestration and door U-factor and product ratingsMOLLY GLENNenergy_progress
05/04/2026Lighting in dwelling unitsMOLLY GLENNenergy_progress
05/04/2026Protection of exposed foundation insulationMOLLY GLENNenergy_progress
05/04/2026Fenestration air leakageMOLLY GLENNenergy_progress
05/04/2026MeteringMOLLY GLENNenergy_progress
05/04/2026Exterior lighting powerMOLLY GLENNenergy_progress
05/04/2026Fenestration areasMOLLY GLENNenergy_progress
05/04/2026Insulation placement and R valuesMOLLY GLENNenergy_progress
05/04/2026Air barrier - visual inspectionMOLLY GLENNenergy_progress
05/04/2026Permanent certificateMOLLY GLENNenergy_progress
05/04/2026Lighting controlsMOLLY GLENNenergy_progress
05/04/2026Concrete - Cast-In-PlaceMOLLY GLENNspecial
05/04/2026Subgrade InspectionsMOLLY GLENNspecial
Latest 25 of 128.
▾Documents — 159 on file (BIS + DOB NOW)
▸Plans & Drawings24
▸DOB NOWPlans/Sketch24
08/17/2026X01324627-I1Request digital key ↗
08/17/2026X00851840-S1Request digital key ↗
08/17/2026X00851840-P6Request digital key ↗
Showing 3 of 24 on file for this type
▸Applications & Permits4
▸DOB NOWDEP Stormwater Construction Permit3
08/13/2026X00851840-P5Open ↗
08/13/2026X00851840-I1Open ↗
08/13/2026X00851840-P1Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
03/31/2025220743060Open ↗
▸Zoning, Tax Lot & Property Records43
▸DOB NOWRestrictive Declaration/Easement 110
08/17/2026X00851840-P6Open ↗
08/13/2026X00851840-P4Open ↗
08/13/2026X00851840-S1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWRestrictive Declaration/Easement 29
08/17/2026X00851840-P6Open ↗
08/17/2026X00851840-S4Open ↗
08/13/2026X00851840-P5Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWRestrictive Declaration/Easement 49
08/17/2026X00851840-P6Open ↗
08/17/2026X00851840-S4Open ↗
08/13/2026X00851840-S2Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWRestrictive Declaration/Easement 39
08/17/2026X00851840-P6Open ↗
08/17/2026X00851840-S4Open ↗
08/13/2026X00851840-P4Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWZD1: DOB Zoning Diagram3
08/13/2026X00851840-I1Open ↗
08/13/2026X00851840-P1Open ↗
08/13/2026X00851840-P5Open ↗
▸DOB NOWZoning Exhibit form (1-5)3
08/13/2026X00851840-P5Open ↗
08/13/2026X00851840-I1Open ↗
08/13/2026X00851840-P1Open ↗
▸Seals & Professional Certifications52
▸DOB NOWDPL-1: Design Professional Seal & Signature26
09/10/2026X01426409-P1Open ↗
09/10/2026X01426409-S4Open ↗
08/17/2026X01324627-I1Open ↗
Showing 3 of 26 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature14
09/01/2026X00851840-S3Open ↗
09/01/2026X00851840-I1Open ↗
09/01/2026X00851840-I1Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWProgress Inspector Seal & Signature12
09/01/2026X00851840-S3Open ↗
09/01/2026X00851840-I1Open ↗
09/01/2026X00851840-I1Open ↗
Showing 3 of 12 on file for this type
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/13/2026X00851840-I1Open ↗
▸DOB NOWStandpipe Alarms Drawings1
08/13/2026X00851840-I1—
▸Safety & Tenant Protection5
▸DOB NOWStreet Tree Checklist3
08/13/2026X00851840-P1Open ↗
08/13/2026X00851840-I1Open ↗
08/13/2026X00851840-P5Open ↗
▸BISBPP: STREET TREES SITE PLAN1
10/27/2025220743060Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026X00851840-I1Open ↗
▸Approvals, Objections & Sign-offs18
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter18
08/17/2026X00851840-P6Open ↗
08/16/2026X01413754-I1Open ↗
08/16/2026X01425191-I1Open ↗
Showing 3 of 18 on file for this type
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
03/31/2025220743060Open ↗
▸Other Documents10
▸DOB NOWSite Survey: Initial3
08/13/2026X00851840-P1Open ↗
08/13/2026X00851840-P5Open ↗
08/13/2026X00851840-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/13/2026X00851840-I1Open ↗
08/13/2026X00851840-P1Open ↗
08/13/2026X00851840-P5Open ↗
▸DOB NOWProperty Ownership Certification3
08/17/2026X00851840-P5Open ↗
08/17/2026X00851840-P1Open ↗
08/17/2026X00851840-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026X00851840-S1Open ↗