| Owner | Filings | Most Recent |
|---|---|---|
| RND 222 | 30 | 07/08/2026 |
| EVAN CONSTRUCTION | 8 | 03/22/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 08/20/2021 | $250K | — | T.J.C. OPERATIONS, INC. → DNR 222 CORP. | — not available |
| Firm | Filings | Most Recent |
|---|---|---|
| M.S. SAVANI ARCHITECT, PC | 13 | 01/23/2026 |
| NY BUILDING ASSOCIATES INC | 1 | 10/21/2025 |
| LMW ENGINEERING GROUP LLC | 5 | 05/05/2025 |
| Representative | Filings | Most Recent |
|---|---|---|
| ARCASTLE | 26 | 03/21/2026 |
| S R SOLAR DESIGN | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| EVAN CONSTURCTION CORP | General Contractor | 13 | 07/08/2026 |
| PRIME PIPING & HEATING IN | Fire Protection | 1 | 07/08/2026 |
| HORBRIDGE PLUMBING & HEATING | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| RAKSHAN MALEK ASSOCIATES | 3352 | 9 | 01/23/2026 |
| NKM ENGINEERING PLLC | 6244 | 1 | 10/21/2025 |
| REGIONAL TESTING CORP. | 394 | 6 | 05/05/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | General Construction | Permit Issued | EVAN CONSTURCTION CORP | 06/25/2025 |
| DOB NOW | Sprinklers | Signed-off | A M B MECHANICAL INC | 06/23/2025 |
| DOB NOW | Plumbing | Signed-off | HORBRIDGE PLUMBING & HEAT | 12/13/2024 |
| DOB NOW | Mechanical Systems | Permit Issued | EVAN CONSTURCTION CORP | 07/05/2024 |
| DOB NOW | Structural | Signed-off | EVAN CONSTURCTION CORP | 07/03/2024 |
| DOB NOW | Earth Work | Signed-off | EVAN CONSTURCTION CORP | 07/03/2024 |
| DOB NOW | Construction Fence | Signed-off | EVAN CONSTURCTION CORP | 06/06/2024 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 01/23/2026 | Permit Issued | EVAN CONSTURCTION CORP | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool General Electric AZ65H12DBM 11,500 BTU · Heat Pump Outdoor ×30 AZ65H15DBM 14,000 BTU · Heat Pump Outdoor ×25 Mitsubishi Electric MUZ-GS30NA2 30,000 BTU · Heat Pump Outdoor ×5 MXZ-SM36NAMHZ2 36,000 BTU · Heat Pump Outdoor ×3 MXZ-2C20NAHZ3 20,000 BTU · Heat Pump Outdoor ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/17/2026 | Permit Issued | BERGER QUALITY ELEC'L CON | — |
| 12/01/2025 | Complete | AV GROUP ELECTRICAL LLC | General Wiring |
| 10/02/2025 | Permit Issued | AV GROUP ELECTRICAL LLC | — |
| Date | Type | Result | Report |
|---|---|---|---|
| 02/27/2026 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 11/25/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 11/07/2025 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 11/05/2025 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 07/09/2025 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 07/09/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 12/20/2024 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 12/20/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 12/20/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 03/02/2026 | Permanent certificate | MARYAM RAKSHAN | energy_progress |
| 03/02/2026 | Maintenance information | MARYAM RAKSHAN | energy_progress |
| 03/02/2026 | Duct leakage testing, insulation and design | MARYAM RAKSHAN | energy_progress |
| 03/02/2026 | Ventilation and air distribution system | MARYAM RAKSHAN | energy_progress |
| 03/02/2026 | HVAC-R and service water heating system controls | MARYAM RAKSHAN | energy_progress |
| 03/02/2026 | HVAC-R and service water piping design and insulation | MARYAM RAKSHAN | energy_progress |
| 03/02/2026 | Metering | MARYAM RAKSHAN | energy_progress |
| 03/02/2026 | HVAC-R and service water heating equipment | MARYAM RAKSHAN | energy_progress |
| 03/02/2026 | Fenestration areas | MARYAM RAKSHAN | energy_progress |
| 03/02/2026 | Insulation placement and R values | MARYAM RAKSHAN | energy_progress |
| 03/02/2026 | Interior lighting power | MARYAM RAKSHAN | energy_progress |
| 03/02/2026 | Fire-Resistance Rated Construction | MARYAM RAKSHAN | progress |
| 03/02/2026 | Protection of exposed foundation insulation | MARYAM RAKSHAN | energy_progress |
| 03/02/2026 | Fenestration air leakage | MARYAM RAKSHAN | energy_progress |
| 03/02/2026 | Air barrier - visual inspection | MARYAM RAKSHAN | energy_progress |
| 03/02/2026 | Electric vehicle service equipment requirements | MARYAM RAKSHAN | energy_progress |
| 03/02/2026 | Air barrier — testing | MARYAM RAKSHAN | energy_progress |
| 03/02/2026 | Fenestration and door U-factor and product ratings | MARYAM RAKSHAN | energy_progress |
| 03/02/2026 | Final | MARYAM RAKSHAN | progress |
| 03/02/2026 | Exterior Insulation and Finish Systems (EIFS) | MARYAM RAKSHAN | special |
| 03/02/2026 | Fire-Resistant Penetrations and Joints | MARYAM RAKSHAN | special |
| 03/02/2026 | Energy Code Compliance Inspections | MARYAM RAKSHAN | progress |
| 03/02/2026 | Mechanical Systems | MARYAM RAKSHAN | special |
| 01/15/2026 | Fenestration areas | MARYAM RAKSHAN | energy_progress |
| 01/15/2026 | Exterior Insulation and Finish Systems (EIFS) | MARYAM RAKSHAN | special |