← Back
Parks / recreation facility
JEROME AVENUE
BRONX · BIN 2008312
💬 Discuss this project
1942Year Built
1Stories
Q1Building Class
PARKZoning
4,345 sfGross Floor Area
1Units
Parks / recreation facility · Owner of record: NYC DEPARTMENT OF PARKS AND RECREATION · 13,402 sf lot · 0.32 FAR built · Flood zone X
Locations of Work
Mechanical
Roof7p · 1 filing · 11 docs
Floor 15p · 1 filing · 11 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
YELLOW CAB HOLDINGS304/09/2026
CITY OF NY PARKS RECREATION DE903/21/2026
WENDYS103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
R.J. MCGEE ENGINEERING, PLLC107/30/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CITY WIDE EXPEDITING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BERKSHIRE REFRIGERATION SGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
R.J. MCGEE ENGINEERING, P9435107/30/2025
Building Lifecycle
All (10)Filed (1)Permit Issued (1)Special Inspection (8)
08/19/2025
Permit issued — Mechanical Systems
X01245917-I1-MS
07/30/2025
Filed — Alteration
MODIFICATION TO HVAC UNITS AND DUCT WORK AS PER PLANS.
X01245917-I1
06/24/2025
Special inspection requirement — Mechanical Systems
Robert McGee
06/24/2025
Special inspection requirement — Final
Robert McGee
06/24/2025
Special inspection requirement — Energy Code Compliance Inspections
Robert McGee
06/24/2025
Special inspection requirement — HVAC-R and service water heating equipment
Robert McGee
06/24/2025
Special inspection requirement — Maintenance information
Robert McGee
06/24/2025
Special inspection requirement — HVAC-R and service water heating system controls
Robert McGee
06/24/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Robert McGee
06/24/2025
Special inspection requirement — Shutoff dampers
Robert McGee
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedBERKSHIRE REFRIGERATION S08/19/2025
BISMHISSUEDCOW BAY SPRINKLER CORP06/22/2005
BISFPISSUEDALLIED FIRE CONTROL06/14/2005
BISEQISSUEDCOW BAY SPRINKLER CORP04/04/2005
BISOTISSUEDCOW BAY SPRINKLER CORP04/04/2005
BIS—ISSUEDCOW BAY SPRINKLER CORP04/04/2005
1 project · most recent 07/30/2025
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
07/30/2025Permit IssuedBERKSHIRE REFRIGERATION SHeating and Air Conditioning Systems
Heat / Cool
Trane YHK210A3S0H YHK120A3S0H 2,700 CFM ×2
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
06/24/2025Mechanical SystemsRobert McGeespecial
06/24/2025FinalRobert McGeeprogress
06/24/2025Energy Code Compliance InspectionsRobert McGeeprogress
06/24/2025HVAC-R and service water heating equipmentRobert McGeeenergy_progress
06/24/2025Maintenance informationRobert McGeeenergy_progress
06/24/2025HVAC-R and service water heating system controlsRobert McGeeenergy_progress
06/24/2025HVAC-R and service water piping design and insulationRobert McGeeenergy_progress
06/24/2025Shutoff dampersRobert McGeeenergy_progress
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/18/2026X01245917-I1Request digital key ↗
▸Seals & Professional Certifications9
▸DOB NOWProgress Inspector Seal & Signature7
09/23/2026X01245917-I1Open ↗
09/23/2026X01245917-I1Open ↗
09/23/2026X01245917-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026X01245917-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/23/2026X01245917-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026X01245917-I1Open ↗