← Back
Parks / recreation facility
Orchard Beach Bath House and Promenade
PELHAM BAY PARK · BIN 2130734
💬 Discuss this project
1935Year Built
6Stories
Q1Building Class
PARKZoning
270,021 sfGross Floor Area
1Units
LL97 Covered8 Open Violations 0 unresolved · 8 paperwork only ▸
Parks / recreation facility · Owner of record: NYC DEPARTMENT OF PARKS AND RECREATION · 74,250,000 sf lot · 0 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingGeneral
Permit Issued — active, not yet Signed-off
Roof2p · 2 filings · 9 docs
Floor 2Under Construction208p · 3 filings · 20 docs
Floor 1Under Construction209p · 7 filings · 20 docs
1 job · most recent 04/30/2026
Air Conditioning Systems Heating and Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
04/30/2026Permit IssuedGILBANE BUILDING COMPANYAir Conditioning Systems, Heating and Air Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Mitsubishi Electric 2x PUHY-EP120TSNU-A1 240,000 BTU · Vrf Outdoor ×1
I MXZ-SM48NAMHZ2-U1 48,000 BTU · Heat Pump Outdoor ×1
MXZ-SM48NAMHZ2-U1 3 48,000 BTU · Heat Pump Outdoor ×1
PUHY-EP120TSNU-A1 120,000 BTU · Vrf Outdoor ×1
RN-006-8-0-E619-000 1,100 CFM · Fan Coil Indoor ×3
RN-018-8-0-H619-000 3,700 CFM · Fan Coil Indoor ×3
Heat / Cool
Mitsubishi Electric PLFY-EP18NEMU-E1R1 20,000 BTU · Vrf Indoor ×18
PLFY-EP30NEMU-ER1 34,000 BTU · Vrf Indoor ×10
PUHY-EP120TSNU-A1 135,000 BTU · Vrf Outdoor ×6
MXZ-SM48NAMHZ2-U1 48,000 BTU · Heat Pump Outdoor ×4
PEFY-P36NMAU-E4 40,000 BTU · Vrf Indoor ×2
PLFY-EP15NEMU-ER1 17,000 BTU · Vrf Indoor ×2
PVFY-P18NAMU-E1 20,000 BTU · Vrf Indoor ×2
PVFY-P24NAMU-E1 27,000 BTU · Vrf Indoor ×2
PVFY-P30NAMU-E1 34,000 BTU · Vrf Indoor ×2
Heating
N/A n/a 87 kW · Electric Heater ×64
Ventilation
N/A n/a 1,390 CFM ×2
1 job · most recent 04/30/2026
Sprinkler System
FiledStatusContractorScope
04/30/2026Signed-offA & F FIRE PROTECTION COSprinkler System
3 jobs · most recent 08/04/2026
Water/Sanitary Storm Gas
FiledStatusContractorScope
08/04/2026——Water/Sanitary
05/28/2026——Storm
04/30/2026Signed-offTRISTATE PLBG SVCS CORPGas, Storm, Water/Sanitary
5 jobs · most recent 09/01/2026
General Wiring
FiledStatusContractorScope
09/01/2026Permit IssuedLIPPOLIS ELECTRIC, INC.General Wiring
05/03/2023CompleteLIPPOLIS ELECTRIC, INC.1 meters
05/12/2022CancelledLOWY & DONNATH INC.—
05/12/2021CompleteP & M ELECT'L CONTR. CORPGeneral Wiring
04/07/2020CompleteE-J ELEC. INSTALLATION COGeneral Wiring
1 job · most recent 04/30/2026
Steel Concrete Masonry
FiledStatusContractorScope
04/30/2026Permit IssuedGILBANE BUILDING COMPANYSteel, Concrete, Masonry
1 job · most recent 04/30/2026
Fence
FiledStatusContractorScope
04/30/2026Permit IssuedGILBANE BUILDING COMPANYFence
1 job · most recent 04/30/2026
Protection and Mechanical Methods
FiledStatusContractorScope
04/30/2026Permit IssuedGILBANE BUILDING COMPANYProtection and Mechanical Methods
Building Lifecycle
All (269)Filed (57)Permit Issued (71)Signed Off (24)Violation (1)Inspection (20)Objection (66)Special Inspection (30)
09/25/2026
Permit issued — General Construction
X01358645-I1-GC
08/17/2026
Permit issued — General Construction
X01433382-I1-GC
08/04/2026
Filed — Alteration
Plumbing work on 1st and 2nd floor as per plans filed herewith. No change in use, egress or occupancy.
X01428535-I1
07/29/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
07/21/2026
Filed — Alteration
Installation of temporary tent, no alt to exist structures for MTA-NYCT Bus Roadeo. TPA permit not required. Producer responsible to monitor site safety & implement HWAP. All production equipment removed upon event completion.
X01433382-I1
07/20/2026
Special inspection requirement — Final
DANNY TRUJILLO
06/23/2026
Permit issued — General Construction
X00642659-I1-GC
06/22/2026
Signed off — Alteration CO
Installation of mechanical systems as per plans
X00642659-S7
05/28/2026
Filed — Alteration
civil plumbing drawings for catch basin work.
X01387047-I1
05/06/2026
Inspection — Pass CND-Occupancy Inspection
Pass
View inspection ↗
05/01/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
NELSON LOPEZ
05/01/2026
Special inspection requirement — Post-installed Anchors
NELSON LOPEZ
04/30/2026
Filed — Alteration CO
Installation of mechanical systems as per plans
X00642659-A2
04/30/2026
Special inspection requirement — Mastic and Intumescent Fire-resistant Coatings
NELSON LOPEZ
04/30/2026
Special inspection requirement — Masonry
NELSON LOPEZ
04/30/2026
Special inspection requirement — Wall Panels, Curtain Walls, and Veneers
NELSON LOPEZ
04/30/2026
Special inspection requirement — Concrete - Cast-In-Place
NELSON LOPEZ
04/30/2026
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
NELSON LOPEZ
04/30/2026
Special inspection requirement — Sprayed fire-resistant materials
NELSON LOPEZ
04/30/2026
Special inspection requirement — Subgrade Inspections
NELSON LOPEZ
04/30/2026
Special inspection requirement — Fire-Resistance Rated Construction
NELSON LOPEZ
04/30/2026
Special inspection requirement — Public Assembly Emergency Lighting
NELSON LOPEZ
04/30/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
NELSON LOPEZ
04/30/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
NELSON LOPEZ
04/30/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
NELSON LOPEZ
04/24/2026
Signed off — Alteration CO
Installation of mechanical systems as per plans
X00642659-S1
04/22/2026
Filed — No Work
X00771919-P4
04/22/2026
Filed — Alteration CO
Installation of mechanical systems as per plans
X00642659-A1
04/15/2026
Objection raised — Other
04/15/2026
Objection resolved — Addressed
04/13/2026
Filed — Alteration CO
Installation of mechanical systems as per plans
X00642659-A3
04/13/2026
Signed off — Alteration CO
Installation of mechanical systems as per plans
X00642659-S6
04/10/2026
Special inspection requirement — Public Assembly Emergency Lighting
NELSON LOPEZ
04/06/2026
Signed off — Alteration CO
Installation of mechanical systems as per plans
X00642659-S4
04/06/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
NELSON LOPEZ
04/06/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
NELSON LOPEZ
04/06/2026
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
NELSON LOPEZ
04/06/2026
Special inspection requirement — Masonry
NELSON LOPEZ
04/06/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
04/06/2026
Special inspection requirement — Mastic and Intumescent Fire-resistant Coatings
NELSON LOPEZ
04/06/2026
Special inspection requirement — Sprayed fire-resistant materials
NELSON LOPEZ
04/06/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
NELSON LOPEZ
04/06/2026
Special inspection requirement — Final
NELSON LOPEZ
04/06/2026
Special inspection requirement — Mechanical Systems
NELSON LOPEZ
04/06/2026
Special inspection requirement — Concrete - Cast-In-Place
NELSON LOPEZ
04/06/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
NELSON LOPEZ
04/06/2026
Special inspection requirement — Post-installed Anchors
NELSON LOPEZ
04/03/2026
Filed — Alteration
EMPTY, PURGE, CLEAN, AND REMOVE (1) 1,000-GALLON GASOLINE UST & (1) 1,000-GALLON BIODIESEL UST. REMOVE ABOVE GROUND PIPING AND EQUIPMENT AND CLEAN AND ABANDON IN-PLACE BELOW GROUND PIPING.
X01358645-I1
04/01/2026
Permit issued — Plumbing
X00642659-S2-PL
03/11/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
02/17/2026
Signed off — Alteration
Installation of shoring as per plans filed herewith. This application is filed in conjunction with DOB X00642659-I1.
X00976845-I1
02/13/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
02/13/2026
Inspection — Certified Sprinkler - SP - Roughing
Certified
View inspection ↗
02/13/2026
Inspection — Certified StandPipe - SD - Fire StandPipe - SD - Roughing
Certified
View inspection ↗
02/13/2026
Inspection — Certified StandPipe-SD-Piping-Hydrostatic Test
Certified
View inspection ↗
01/29/2026
Filed — Alteration CO
Installation of mechanical systems as per plans
X00642659-P8
01/20/2026
Filed — Alteration CO
Installation of mechanical systems as per plans
X00642659-P9
01/08/2026
Signed off — Alteration CO
Installation of mechanical systems as per plans
X00642659-S9
12/22/2025
Filed — No Work
X00771909-P2
12/22/2025
Filed — No Work
X00771919-P2
Latest 60 of 269 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
DEPARTMENT OF DESIGN CONSTRUCTION109/26/2026
GILBANE103/22/2026
OXFORD PROPERTIES GROUP103/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CONVERSANO ASSOCIATES, INC.5203/21/2026
A1 EXPEDITING SERVICE2203/21/2026
HOWARD I SHAPIRO ASSOCIATES1203/21/2026
MUNICIPAL BUILDING CONSULTANTS203/21/2026
CITISCAPE CONSULTING LTD603/21/2026
ARCHI PRO GROUP103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SAFWAY ATLANTIC, LLCGeneral Contractor3107/08/2026
GILBANE BUILDING COMPANYGeneral Contractor1807/08/2026
ENERGY FENCING INCGeneral Contractor1506/28/2026
TITAN INDUSTRIAL SVC CORPGeneral Contractor807/08/2026
TRISTATE PLBG SVCS CORPPlumbing407/08/2026
PACE PLUMBING CORPFire Protection407/08/2026
A & F FIRE PROTECTION COFire Protection207/08/2026
DARCON CONSTRUCTION INCGeneral Contractor204/09/2026
WINICK PRODUCTIONS, LLCGeneral Contractor207/08/2026
CIVETTA MECHANICAL, LLCPlumbing207/08/2026
GLASS ARMOR OF NEW YORK IGeneral Contractor109/26/2026
A.F.I. GLASS & ARCHITECTUGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
UNIVERSAL TESTING AND INS4003104/30/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedGLASS ARMOR OF NEW YORK I09/25/2026
DOB NOWGeneral ConstructionPermit IssuedCOLGATE ENTERPRISE CORP08/17/2026
DOB NOWGeneral ConstructionPermit IssuedGILBANE BUILDING COMPANY06/23/2026
DOB NOWPlumbingSigned-offTRISTATE PLBG SVCS CORP04/01/2026
DOB NOWConstruction FenceSigned-offENERGY FENCING INC10/06/2025
DOB NOWProtection and Mechanical MethodsSigned-offSAFWAY ATLANTIC, LLC09/29/2025
DOB NOWProtection and Mechanical MethodsSigned-offSAFWAY ATLANTIC, LLC09/25/2025
DOB NOWProtection and Mechanical MethodsSigned-offA.F.I. GLASS & ARCHITECTU09/03/2025
DOB NOWGeneral ConstructionSigned-offWINICK PRODUCTIONS, LLC08/21/2025
DOB NOWGeneral ConstructionPermit IssuedGILBANE BUILDING COMPANY06/24/2025
DOB NOWMechanical SystemsSigned-offGILBANE BUILDING COMPANY06/23/2025
DOB NOWEarth WorkSigned-offGILBANE BUILDING COMPANY06/23/2025
DOB NOWSprinklersSigned-offADVANCED AUTO SPR.CO.,INC06/04/2025
DOB NOWSprinklersSigned-offADVANCED AUTO SPR.CO.,INC06/04/2025
DOB NOWProtection and Mechanical MethodsSigned-offSAFWAY ATLANTIC, LLC06/03/2025
DOB NOWPlumbingSigned-offTRISTATE PLBG SVCS CORP04/01/2025
DOB NOWStructuralSigned-offGILBANE BUILDING COMPANY02/13/2025
DOB NOWPlumbingSigned-offCIVETTA MECHANICAL, LLC02/07/2025
DOB NOWConstruction FenceSigned-offENERGY FENCING INC01/15/2025
DOB NOWStructuralSigned-offDARCON CONSTRUCTION INC01/09/2025
DOB NOWSprinklersSigned-offMANENGEERING BUREAU, INC12/19/2024
DOB NOWSprinklersSigned-offMANENGEERING BUREAU, INC12/17/2024
DOB NOWProtection and Mechanical MethodsSigned-offSAFWAY ATLANTIC, LLC11/01/2024
DOB NOWProtection and Mechanical MethodsSigned-offSAFWAY ATLANTIC, LLC10/02/2024
DOB NOWSupported ScaffoldSigned-offSAFWAY ATLANTIC, LLC10/02/2024
DOB NOWProtection and Mechanical MethodsSigned-offSAFWAY ATLANTIC, LLC09/27/2024
DOB NOWProtection and Mechanical MethodsSigned-offSAFWAY ATLANTIC, LLC09/27/2024
DOB NOWProtection and Mechanical MethodsSigned-offSAFWAY ATLANTIC, LLC09/27/2024
DOB NOWProtection and Mechanical MethodsSigned-offSAFWAY ATLANTIC, LLC09/26/2024
DOB NOWSidewalk ShedSigned-offSAFWAY ATLANTIC, LLC09/26/2024
DOB NOWSupported ScaffoldSigned-offSAFWAY ATLANTIC, LLC09/25/2024
DOB NOWGeneral ConstructionPermit IssuedGILBANE BUILDING COMPANY09/13/2024
DOB NOWMechanical SystemsSigned-offGILBANE BUILDING COMPANY09/13/2024
DOB NOWGeneral ConstructionSigned-offGILBANE BUILDING COMPANY09/12/2024
DOB NOWStandpipeSigned-offMANENGEERING BUREAU, INC09/10/2024
DOB NOWStandpipeSigned-offMANENGEERING BUREAU, INC09/10/2024
DOB NOWConstruction FenceSigned-offENERGY FENCING INC09/09/2024
DOB NOWGeneral ConstructionSigned-offWINICK PRODUCTIONS, LLC08/14/2024
DOB NOWPlumbingSigned-offTRISTATE PLBG SVCS CORP04/01/2024
DOB NOWConstruction FenceSigned-offENERGY FENCING INC03/14/2024
+ 13 more permits on file
▾Field Inspections (DOB CAP) — 20
DateTypeResultReport
05/06/2026Pass CND-Occupancy InspectionPassView ↗
03/11/2026Pass-Final CND-Occupancy InspectionPassView ↗
02/13/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
02/13/2026Certified Sprinkler - SP - RoughingCertifiedView ↗
02/13/2026Certified StandPipe - SD - Fire StandPipe - SD - RoughingCertifiedView ↗
02/13/2026Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
04/03/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
01/03/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/18/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
07/22/2024Pass-Final PL - UndergroundPassView ↗
05/20/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
05/09/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
04/05/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/02/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
03/27/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
11/06/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/03/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/27/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/27/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
07/08/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 146
DateRequirementInspectorRole
07/29/2026Fire-Resistant Penetrations and Joints—special
07/20/2026FinalDANNY TRUJILLOprogress
05/01/2026Post-installed AnchorsNELSON LOPEZspecial
05/01/2026Fire-Resistant Penetrations and JointsNELSON LOPEZspecial
04/30/2026Mastic and Intumescent Fire-resistant CoatingsNELSON LOPEZspecial
04/30/2026MasonryNELSON LOPEZspecial
04/30/2026Excavations - Sheeting, Shoring, and BracingNELSON LOPEZspecial
04/30/2026Structural Stability – Alterations of existing buildingsNELSON LOPEZspecial
04/30/2026Wall Panels, Curtain Walls, and VeneersNELSON LOPEZspecial
04/30/2026Subgrade InspectionsNELSON LOPEZspecial
04/30/2026Fire-Resistant Penetrations and JointsNELSON LOPEZspecial
04/30/2026Fire-Resistance Rated ConstructionNELSON LOPEZprogress
04/30/2026Concrete - Cast-In-PlaceNELSON LOPEZspecial
04/30/2026Public Assembly Emergency LightingNELSON LOPEZprogress
04/30/2026Sprayed fire-resistant materialsNELSON LOPEZspecial
04/30/2026Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)NELSON LOPEZspecial
04/10/2026Public Assembly Emergency LightingNELSON LOPEZprogress
04/06/2026Sprayed fire-resistant materialsNELSON LOPEZspecial
04/06/2026Fire-Resistant Penetrations and JointsNELSON LOPEZspecial
04/06/2026Mechanical SystemsNELSON LOPEZspecial
04/06/2026Post-installed AnchorsNELSON LOPEZspecial
04/06/2026Structural Stability – Alterations of existing buildings—special
04/06/2026FinalNELSON LOPEZprogress
04/06/2026Post-installed AnchorsNELSON LOPEZspecial
04/06/2026Fire-Resistant Penetrations and JointsNELSON LOPEZspecial
Latest 25 of 146.
▾Documents — 379 on file (BIS + DOB NOW)
▸Plans & Drawings57
▸DOB NOWPlans/Sketch44
08/24/2026X00679419-I1Request digital key ↗
08/23/2026X00817760-I1Request digital key ↗
08/23/2026X00817750-P1Request digital key ↗
Showing 3 of 44 on file for this type
▸DOB NOWPlans/Sketch - Place of Assembly10
08/24/2026X00771877-P2Request digital key ↗
08/24/2026X00771877-P1Request digital key ↗
08/24/2026X00771877-I1Request digital key ↗
Showing 3 of 10 on file for this type
▸DOB NOWPlans/Sketch - Temporary Place of Assembly3
08/22/2026X00903034-I1Request digital key ↗
08/21/2026X01075692-I1Request digital key ↗
08/19/2026X01244054-I1Request digital key ↗
▸Applications & Permits36
▸DOB NOWLPC Approval/Permit23
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 23 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION9
05/16/2024220199327Open ↗
04/16/2024240275956Open ↗
04/01/2024240275956Open ↗
Showing 3 of 9 on file for this type
▸BISWORK PERMIT APPLICATION3
06/23/2020240275956Open ↗
08/25/2012220199327Open ↗
06/22/2012220192066Open ↗
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications1
09/03/2014220192066Open ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Seals & Professional Certifications135
▸DOB NOWDPL-1: Design Professional Seal & Signature57
08/24/2026X00679419-I1Open ↗
08/24/2026X00771877-I1Open ↗
08/24/2026X00771877-P2Open ↗
Showing 3 of 57 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature44
09/27/2026X00836578-I1Open ↗
09/27/2026X00836578-I1Open ↗
09/27/2026X00836578-I1Open ↗
Showing 3 of 44 on file for this type
▸DOB NOWProgress Inspector Seal & Signature27
09/29/2026X00771919-P1Open ↗
09/27/2026X00836578-I1Open ↗
09/27/2026X00682317-P1Open ↗
Showing 3 of 27 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
08/24/2012220199327Open ↗
06/20/2012220192066Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
06/22/2020240275956Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
08/24/2012220199327Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
06/22/2020240275956Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
08/24/2012220199327Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
06/22/2020240275956Open ↗
▸Safety & Tenant Protection9
▸DOB NOWStreet Tree Checklist7
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 7 on file for this type
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form7
08/24/2026X00679419-I1Open ↗
08/16/2026X00642659-S2Open ↗
08/16/2026X00642659-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/17/2026X01358645-I1Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY2
03/26/2024240275956Open ↗
06/22/2020240275956Open ↗
▸DOB NOWTR5 Test Report1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Approvals, Objections & Sign-offs108
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter57
08/24/2026X00679419-I1Open ↗
08/21/2026X00682317-P2Open ↗
08/18/2026X00771909-P2Open ↗
Showing 3 of 57 on file for this type
▸DOB NOWDesign Commission Approval City Owned (Exterior Work)19
08/17/2026X01358645-I1Open ↗
Showing 1 of 19 on file for this type
▸DOB NOWDesign Commission Sign Off City Owned (Exterior Work)10
08/16/2026X00642659-S7Open ↗
Showing 1 of 10 on file for this type
▸DOB NOWDEP Variance (V5) letter10
08/24/2026X00679419-I1Open ↗
08/15/2026X00682317-I1Open ↗
Showing 2 of 10 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST5
05/31/2024220199327Open ↗
04/04/2024240275956Open ↗
06/08/2021240275956Open ↗
Showing 3 of 5 on file for this type
▸BISFINAL2
05/29/2024220199327Open ↗
04/02/2024240275956Open ↗
▸BISADMINISTRATIVE OBJECTIONS2
08/24/2012220199327Open ↗
06/20/2012220192066Open ↗
▸BISLANDMARKS APPROVAL1
06/22/2020240275956Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
08/24/2012220199327Open ↗
▸BISLANDMARKS SIGNOFF1
06/08/2021240275956Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT2
06/22/2020240275956Open ↗
06/20/2012220192066Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
06/08/2021240275956Open ↗
▸Filing & Intake Forms6
▸BISADDITIONAL INFORMATION3
06/22/2020240275956Open ↗
06/22/2020240275956Open ↗
06/22/2020240275956Open ↗
▸BISEFILING COVER SHEET2
08/24/2012220199327Open ↗
06/20/2012220192066Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
06/22/2020240275956Open ↗
▸Other Documents13
▸DOB NOWProof of Historic Building9
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 9 on file for this type
▸DOB NOWFee Exempt Supporting Document - DOF Property Tax Assessment Roll1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWPARTIAL DEMO: 10-DAY Notice1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWFinal Survey1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWAdjoining Owners Notification1
08/13/2026X00682317-I1Open ↗