← Back
Over six families without stores
SEDGWICK AVENUE
BRONX · BIN 2830857
💬 Discuss this project
2022Year Built
4Stories
C1Building Class
R6Zoning
7,360 sfGross Floor Area
10Units
Rent Stabilized2 Open Violations ▸
Over six families without stores · Owner of record: 2809 SEDGWICK LLC · 2,447 sf lot · 3.01 FAR built · Flood zone X
Locations of Work
ArchitectureStructural
Roof17p · 1 filing · 20 docs
Bulkhead1p · 1 filing · 5 docs
Penthouse16p · 1 filing · 20 docs
Floor 416p · 1 filing · 20 docs
Floor 316p · 1 filing · 20 docs
Floor 216p · 1 filing · 20 docs
Floor 116p · 1 filing · 20 docs
Cellar16p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
2809 SEDWICK AVE4607/08/2026
ZKW ENTERPRISES407/08/2026
NEW LINE CONSTRUCTION803/22/2026
SEDGWICK DEVELOPMENT603/21/2026
2809 SEDGWICK LLC103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/25/2021$325K—Private party → 2809 SEDGWICK LLC— not available
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NODE ARCHITECTURE,ENGINEERING, CONS1107/15/2024
ASR ENGINEERING PC101/09/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NODE ARCH ENGIN CONSULT603/21/2026
ADVANCED BUILDERS SERVICES103/21/2026
NODE ARCHITECTURE ENGINEERING CON803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NEW LINE CONSTRUCTION LLCGeneral Contractor1907/08/2026
GO PRO FIRE PROTECTION CFire Protection107/08/2026
ZKW ENTERPRISES INCGeneral Contractor107/08/2026
INFINITI ESC PLUMBING CORPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NODE ARCHITECTURE,ENGINEE67991007/15/2024
INTERNATIONAL GEOTEHCNICA1795612/22/2023
Building Lifecycle
All (85)Filed (12)Permit Issued (15)Signed Off (8)Violation (11)Inspection (9)Special Inspection (30)
07/22/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/18/2024
Special inspection requirement — Metering
Radomir Delic
07/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Radomir Delic
07/18/2024
Special inspection requirement — Energy Code Compliance Inspections
Radomir Delic
07/18/2024
Special inspection requirement — Fire-Resistance Rated Construction
Radomir Delic
07/18/2024
Special inspection requirement — Lighting in dwelling units
Radomir Delic
07/18/2024
Special inspection requirement — Fenestration areas
Radomir Delic
07/18/2024
Special inspection requirement — Lighting controls
Radomir Delic
07/18/2024
Special inspection requirement — Protection of exposed foundation insulation
Radomir Delic
07/18/2024
Special inspection requirement — Interior lighting power
Radomir Delic
07/18/2024
Special inspection requirement — Insulation placement and R values
Radomir Delic
07/18/2024
Special inspection requirement — Exterior lighting power
Radomir Delic
07/18/2024
Special inspection requirement — Air barrier - visual inspection
Radomir Delic
07/18/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
Radomir Delic
07/18/2024
Special inspection requirement — Fenestration air leakage
Radomir Delic
07/18/2024
Special inspection requirement — Maintenance information
Radomir Delic
07/15/2024
Filed — New Building
NEW MECHANICAL SYSTEMS INSTALLATION IN CONJUCTION WITH NEW BUILDING APPLICATION # X00520505-I1. ALL AS PER PLANS FILED. NO CHANGE TO USE EGRESS OR OCCUPANCY.
X00520505-P4
07/12/2024
Special inspection requirement — Lighting in dwelling units
Radomir Delic
07/12/2024
Special inspection requirement — Insulation placement and R values
Radomir Delic
07/12/2024
Special inspection requirement — Lighting controls
Radomir Delic
07/12/2024
Special inspection requirement — Fenestration areas
Radomir Delic
07/12/2024
Special inspection requirement — Maintenance information
Radomir Delic
07/12/2024
Special inspection requirement — Protection of exposed foundation insulation
Radomir Delic
07/12/2024
Special inspection requirement — Fenestration air leakage
Radomir Delic
07/12/2024
Special inspection requirement — Metering
Radomir Delic
07/12/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Radomir Delic
07/12/2024
Special inspection requirement — Energy Code Compliance Inspections
Radomir Delic
07/12/2024
Special inspection requirement — Fire-Resistance Rated Construction
Radomir Delic
07/12/2024
Special inspection requirement — Air barrier - visual inspection
Radomir Delic
07/12/2024
Special inspection requirement — Interior lighting power
Radomir Delic
07/12/2024
Special inspection requirement — Exterior lighting power
Radomir Delic
07/12/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
Radomir Delic
03/21/2024
Signed off — Alteration
X00808514-I1
03/13/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/07/2024
Signed off — New Building
NEW MECHANICAL SYSTEMS INSTALLATION IN CONJUCTION WITH NEW BUILDING APPLICATION # X00520505-I1. ALL AS PER PLANS FILED. NO CHANGE TO USE EGRESS OR OCCUPANCY.
X00520505-S3
03/07/2024
Signed off — New Building
NEW MECHANICAL SYSTEMS INSTALLATION IN CONJUCTION WITH NEW BUILDING APPLICATION # X00520505-I1. ALL AS PER PLANS FILED. NO CHANGE TO USE EGRESS OR OCCUPANCY.
X00520505-S1
01/10/2024
Signed off — Alteration
Construction Fence filed in Conjunction with NB Application #X00520505-I1
X00505290-I1
01/10/2024
Signed off — New Building
NEW MECHANICAL SYSTEMS INSTALLATION IN CONJUCTION WITH NEW BUILDING APPLICATION # X00520505-I1. ALL AS PER PLANS FILED. NO CHANGE TO USE EGRESS OR OCCUPANCY.
X00520505-S2
12/22/2023
Filed — New Building
NEW MECHANICAL SYSTEMS INSTALLATION IN CONJUCTION WITH NEW BUILDING APPLICATION # X00520505-I1. ALL AS PER PLANS FILED. NO CHANGE TO USE EGRESS OR OCCUPANCY.
X00520505-P2
11/27/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
11/16/2023
Permit issued — General Construction
X00520505-I1-GC
11/13/2023
Permit issued — Construction Fence
X00505290-I1-FN
11/13/2023
Permit issued — Mechanical Systems
X00520505-S3-MS
10/02/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
09/27/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
07/18/2023
Signed off — Alteration
Structural work filed in conjunction with NB application #X00520505
X00505405-I1
06/09/2023
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
06/09/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/31/2023
Signed off — Alteration
Earthwork and Foundation work filed in conjunction with NB app # X00520505-I1
X00609040-I1
05/05/2023
Violation issued (ECB, closed)
Site Safety
04/21/2023
Violation issued (ECB, closed)
Site Safety
02/22/2023
Permit issued — Sprinklers
X00520505-S2-EW-SP
02/18/2023
Violation issued (ECB, closed)
Construction
02/18/2023
Violation issued (ECB, closed)
Construction
01/24/2023
Violation issued (ECB, closed)
Unknown
01/24/2023
Violation issued (ECB, closed)
Construction
01/24/2023
Violation issued (ECB, closed)
Site Safety
01/24/2023
Violation issued (ECB, closed)
Construction
01/19/2023
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
01/19/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
Latest 60 of 85 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedNEW LINE CONSTRUCTION LLC11/16/2023
DOB NOWConstruction FenceSigned-offNEW LINE CONSTRUCTION LLC11/13/2023
DOB NOWMechanical SystemsSigned-offNEW LINE CONSTRUCTION LLC11/13/2023
DOB NOWSprinklersSigned-offGO PRO FIRE PROTECTION C02/22/2023
DOB NOWSidewalk ShedSigned-offZKW ENTERPRISES INC01/09/2023
DOB NOWPlumbingSigned-offINFINITI ESC PLUMBING COR01/06/2023
DOB NOWStructuralSigned-offNEW LINE CONSTRUCTION LLC12/20/2022
DOB NOWGeneral ConstructionPermit IssuedNEW LINE CONSTRUCTION LLC12/14/2022
DOB NOWConstruction FenceSigned-offNEW LINE CONSTRUCTION LLC11/03/2022
DOB NOWSupport of ExcavationSigned-offNEW LINE CONSTRUCTION LLC11/03/2022
DOB NOWEarth WorkSigned-offNEW LINE CONSTRUCTION LLC11/02/2022
DOB NOWMechanical SystemsSigned-offNEW LINE CONSTRUCTION LLC09/05/2022
DOB NOWSupport of ExcavationSigned-offNEW LINE CONSTRUCTION LLC02/01/2022
DOB NOWEarth WorkSigned-offNEW LINE CONSTRUCTION LLC02/01/2022
DOB NOWConstruction FenceSigned-offNEW LINE CONSTRUCTION LLC01/24/2022
1 project · most recent 07/15/2024
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
07/15/2024Permit IssuedNEW LINE CONSTRUCTION LLCHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MSZ-FS09NA-U1 10,900 BTU · Fan Coil Indoor ×30
MXZ-2C20NAHZ4-U1 22,000 BTU · Condensing Unit ×10
MUZ-FS09NAH-U1 10,900 BTU · Condensing Unit ×8
MSZ-FS12NA-U1 12,300 BTU · Fan Coil Indoor ×4
MUZ-FS12NAH-U1 14,400 BTU · Condensing Unit ×4
1 project · most recent 07/15/2024
Sprinkler System
FiledStatusContractorScope
07/15/2024Signed-offGO PRO FIRE PROTECTION CSprinkler System
1 project · most recent 07/15/2024
Storm Water/Sanitary
FiledStatusContractorScope
07/15/2024Signed-offINFINITI ESC PLUMBING CORStorm, Water/Sanitary
2 projects · most recent 04/15/2024
General Wiring
FiledStatusContractorScope
04/15/2024CompleteDENNISON ELECTRIC CORPGeneral Wiring
01/10/2023CompleteRICHARD NEU—
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
07/22/2024Pass-Final CND-Occupancy InspectionPassView ↗
03/13/2024Pass-Final CND-Occupancy InspectionPassView ↗
11/27/2023Fail-Final General Construction Non-Directive 14FailView ↗
10/02/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
09/27/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
06/09/2023Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
06/09/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/19/2023Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
01/19/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 44
DateRequirementInspectorRole
07/18/2024MeteringRadomir Delicenergy_progress
07/18/2024Fire-Resistant Penetrations and JointsRadomir Delicspecial
07/18/2024Energy Code Compliance InspectionsRadomir Delicprogress
07/18/2024Fire-Resistance Rated ConstructionRadomir Delicprogress
07/18/2024Lighting in dwelling unitsRadomir Delicenergy_progress
07/18/2024Fenestration areasRadomir Delicenergy_progress
07/18/2024Lighting controlsRadomir Delicenergy_progress
07/18/2024Protection of exposed foundation insulationRadomir Delicenergy_progress
07/18/2024Interior lighting powerRadomir Delicenergy_progress
07/18/2024Insulation placement and R valuesRadomir Delicenergy_progress
07/18/2024Exterior lighting powerRadomir Delicenergy_progress
07/18/2024Air barrier - visual inspectionRadomir Delicenergy_progress
07/18/2024Fenestration and door U-factor and product ratingsRadomir Delicenergy_progress
07/18/2024Fenestration air leakageRadomir Delicenergy_progress
07/18/2024Maintenance informationRadomir Delicenergy_progress
07/12/2024Lighting in dwelling unitsRadomir Delicenergy_progress
07/12/2024Insulation placement and R valuesRadomir Delicenergy_progress
07/12/2024Lighting controlsRadomir Delicenergy_progress
07/12/2024Fenestration areasRadomir Delicenergy_progress
07/12/2024Maintenance informationRadomir Delicenergy_progress
07/12/2024Protection of exposed foundation insulationRadomir Delicenergy_progress
07/12/2024Fenestration air leakageRadomir Delicenergy_progress
07/12/2024MeteringRadomir Delicenergy_progress
07/12/2024Fire-Resistant Penetrations and JointsRadomir Delicspecial
07/12/2024Energy Code Compliance InspectionsRadomir Delicprogress
Latest 25 of 44.
▾Documents — 109 on file (BIS + DOB NOW)
▸Plans & Drawings12
▸DOB NOWPlans/Sketch12
08/25/2026X00505290-I1Request digital key ↗
08/25/2026X00609045-P1Request digital key ↗
08/25/2026X00609045-I1Request digital key ↗
Showing 3 of 12 on file for this type
▸Applications & Permits9
▸BISPLAN / WORK APPROVAL APPLICATION8
03/04/2024240304899Open ↗
12/12/2023240304899Open ↗
09/21/2023240304899Open ↗
Showing 3 of 8 on file for this type
▸BISBPP-5 - Authorization to the Department of Transportation1
07/14/2022240304899Open ↗
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026X00520505-I1Open ↗
08/13/2026X00520505-P4Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/13/2026X00520505-I1Open ↗
08/13/2026X00520505-P4Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026X00520505-I1Open ↗
▸Seals & Professional Certifications55
▸DOB NOWProgress Inspector Seal & Signature32
08/28/2026X00520505-P4Open ↗
08/28/2026X00520505-P4Open ↗
08/28/2026X00520505-P4Open ↗
Showing 3 of 32 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature12
08/25/2026X00505290-I1Open ↗
08/25/2026X00609045-I1Open ↗
08/25/2026X00609045-P1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature10
09/01/2026X00609045-I1Open ↗
09/01/2026X00609045-I1Open ↗
08/28/2026X00520505-P4Open ↗
Showing 3 of 10 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
08/23/2021240304899Open ↗
▸Trade Schedules & Equipment3
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/13/2026X00520505-P4Open ↗
08/13/2026X00520505-I1Open ↗
▸DOB NOWStandpipe Alarms Drawings1
08/13/2026X00520505-I1—
▸Safety & Tenant Protection6
▸DOB NOWStreet Tree Checklist2
08/13/2026X00520505-P4Open ↗
08/13/2026X00520505-I1Open ↗
▸BISSTREET TREE CHECKLIST1
07/14/2022240304899Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026X00520505-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026X00520505-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026X00520505-I1Open ↗
▸Energy Compliance3
▸DOB NOWPreliminary Commissioning Report Certification2
08/13/2026X00520505-S1Open ↗
08/13/2026X00520505-S3Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026X00520505-I1Open ↗
▸Cost, Insurance & Ownership2
▸DOB NOWCertification by Insurance Broker or Agency1
08/13/2026X00520505-I1Open ↗
▸DOB NOWCertificate of Insurance1
08/13/2026X00520505-I1Open ↗
▸Filing & Intake Forms4
▸BISADDITIONAL INFORMATION3
03/06/2024240304899Open ↗
03/04/2024240304899Open ↗
07/14/2022240304899Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
08/23/2021240304899Open ↗
▸Other Documents10
▸BISBPP - SUPPORTING DOCUMENTATION2
07/07/2022240304899Open ↗
07/07/2022240304899Open ↗
▸DOB NOWSite Survey: Initial2
08/13/2026X00520505-I1Open ↗
08/13/2026X00520505-P4Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026X00520505-I1Open ↗
08/13/2026X00520505-P4Open ↗
▸DOB NOWAdjoining Owners Notification2
08/13/2026X00609040-I1Open ↗
08/13/2026X00609045-I1Open ↗
▸DOB NOWFinal Survey1
08/13/2026X00520505-I1Open ↗
▸DOB NOWAdditional Insured Authorizations1
08/13/2026X00520505-I1Open ↗