← Back
Elevator apt, fireproof with stores
Willets Point Commons
WILLETS POINT BLVD · BIN 4624494
💬 Discuss this project
2024Year Built
12Stories
D6Building Class
C4-4Zoning
515,225 sfGross Floor Area
535Units
0 Open Violations
Elevator apt, fireproof with stores · Owner of record: NYC HOUSING PRESERVATION AND DEVELOPMENT · 62,066 sf lot · 8.3 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction73p · 1 filing · 20 docs
Floor 12Under Construction49p · 1 filing · 20 docs
Floor 11Under Construction49p · 1 filing · 20 docs
Floor 10Under Construction53p · 1 filing · 20 docs
Floor 9Under Construction54p · 1 filing · 20 docs
Floor 8Under Construction57p · 1 filing · 20 docs
Floor 7Under Construction54p · 1 filing · 20 docs
Floor 6Under Construction50p · 1 filing · 20 docs
Floor 5Under Construction51p · 1 filing · 20 docs
Floor 4Under Construction50p · 1 filing · 20 docs
Floor 3Under Construction50p · 1 filing · 20 docs
Floor 2Under Construction281p · 1 filing · 20 docs
Floor 1Under Construction289p · 3 filings · 20 docs
CellarUnder Construction287p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
WILLETS POINT PHASE I OWNER13909/13/2026
QUEENS DEVELOPMENT GROUP, LLC607/08/2026
NYC HOUSING PRESERVATION AND DEVELOPMENT103/22/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
RELATED COMPANIES2803/21/2026
A1 EXPEDITING SERVICE1203/21/2026
THE GREEN STUDIO903/21/2026
LOUIS STRIAR1003/21/2026
MRA ENGINEERING P C203/21/2026
MILLENNIUM DESIGNS903/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HUDSON YARDS CONST II LLCGeneral Contractor4307/08/2026
MC SUPERSTRUCTURE INCGeneral Contractor807/08/2026
RAEL AUTOMATIC SPR.CO INCFire Protection807/08/2026
S&E BRIDGE & SCAFFOLD LLC.General Contractor607/08/2026
ACTIVE SIGNSScaffold507/08/2026
ALMAR PLUMBING & HTG CORPPlumbing507/08/2026
PDI NYC ELECTRIC, LLCElectrical203/22/2026
KATAN P & H INCPlumbing107/08/2026
AYA DECORGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ENGINEERING CONSULTING SE2050408/26/2026
DOMANI INSPECTION SERVICE8432003/25/2026
SOCOTEC, INC.301402/24/2026
DESIMONE CONSULTING ENGIN5942407/30/2025
LANGAN ENG, ENV, SURVEYIN1265212/14/2023
Building Lifecycle
All (274)Filed (59)Permit Issued (59)Signed Off (21)Violation (10)Inspection (16)Objection (79)Special Inspection (30)
08/26/2026
Filed — Alteration
INTERIOR RENOVATION IN EXISTING 1st FL COMMERCIAL SPACE FOR PROPOSED GROCERY & CONVENIENCE RETAILER W/ COMMERCIAL COOKING. NEW HOOD & EXHAUST. ASSOCIATED PLUMBING WORK TO BE FILED SUBSEQUENTLY. The store address AKA 126-28 Willets Point Boulevard
Q01322347-P2
08/24/2026
Special inspection requirement — Final
GHANENDRA MISHRA
08/18/2026
Filed — Alteration
ILLUMINATED NON-ADVERTISING ACCESSORY WALL SIGN - IN PROPERTY LINES - 126-43 39TH AVENUE WILLETS POINT COMMONS. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
Q01353021-P1
08/13/2026
Signed off — Alteration
THIS APPLICATION IS FILED FOR CONSTRUCTION EQUIPMENT, FOR THE CONSTRUCTION OF A TEMPORARY CONSTRUCTION OFFICE INSIDE THE BUILDING BEING BUILT AS PER THE PLANS FILED HEREWITH.
Q01233505-I1
07/27/2026
Signed off — Alteration
THIS APPLICATION FILED ONLY TO DELIVER AND INSTALL PHOTOVOLTAIC ARRAYS AND SUPPORT EQUIPMENT ON ROOF. ALL ACTUAL CONSTRUCTION WORK PERFORMED UNDER APPLICATION Q08032504-I1. SOLAR APPLICATION TO BE FILED SEPARATELY. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01368236-I1
07/21/2026
Signed off — New Building
SPRINKLER AND STANDPIPE WORK RELATED TO THE CONSTRUCTION OF A NEW 12 STORY AFFORDABLE HOUSING BUILDING AS PER PLANS FILED HEREWITH.
Q08032504-S4
07/21/2026
Signed off — New Building
SPRINKLER AND STANDPIPE WORK RELATED TO THE CONSTRUCTION OF A NEW 12 STORY AFFORDABLE HOUSING BUILDING AS PER PLANS FILED HEREWITH.
Q08032504-Z1
07/21/2026
Signed off — New Building
SPRINKLER AND STANDPIPE WORK RELATED TO THE CONSTRUCTION OF A NEW 12 STORY AFFORDABLE HOUSING BUILDING AS PER PLANS FILED HEREWITH.
Q08032504-S6
07/15/2026
Filed — Alteration
INTERIOR RENOVATION IN EXISTING 1st FL COMMERCIAL SPACE FOR PROPOSED GROCERY & CONVENIENCE RETAILER W/ COMMERCIAL COOKING. NEW HOOD & EXHAUST. ASSOCIATED PLUMBING WORK TO BE FILED SUBSEQUENTLY. The store address AKA 126-28 Willets Point Boulevard
Q01322347-S2
07/14/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
07/10/2026
Special inspection requirement — Tenant Protection Plan Compliance
07/06/2026
Special inspection requirement — Sprinkler Systems
06/30/2026
Special inspection requirement — Shutoff dampers
JOHN MCMONAGLE
06/30/2026
Special inspection requirement — HVAC-R and service water heating equipment
JOHN MCMONAGLE
06/30/2026
Special inspection requirement — Heating Systems
JOHN MCMONAGLE
06/30/2026
Special inspection requirement — Emergency and Standby Power Systems (Generator)
JOHN MCMONAGLE
06/30/2026
Special inspection requirement — Exterior lighting power
JOHN MCMONAGLE
06/30/2026
Special inspection requirement — Duct leakage testing, insulation and design
JOHN MCMONAGLE
06/30/2026
Special inspection requirement — Maintenance information
JOHN MCMONAGLE
06/30/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
JOHN MCMONAGLE
06/30/2026
Special inspection requirement — Lighting in dwelling units
JOHN MCMONAGLE
06/30/2026
Special inspection requirement — Ventilation and air distribution system
JOHN MCMONAGLE
06/30/2026
Special inspection requirement — Metering
JOHN MCMONAGLE
06/30/2026
Special inspection requirement — HVAC-R and service water heating system controls
JOHN MCMONAGLE
06/30/2026
Special inspection requirement — Final
JOHN MCMONAGLE
06/30/2026
Special inspection requirement — Interior lighting power
JOHN MCMONAGLE
06/30/2026
Special inspection requirement — Lighting controls
JOHN MCMONAGLE
06/30/2026
Special inspection requirement — Electrical motors and elevators
JOHN MCMONAGLE
06/30/2026
Special inspection requirement — Mechanical Systems
JOHN MCMONAGLE
06/11/2026
Special inspection requirement — HVAC-R and service water heating equipment
PAUL MARINO
06/11/2026
Special inspection requirement — Tenant Protection Plan Compliance
PAUL MARINO
06/11/2026
Special inspection requirement — Energy Code Compliance Inspections
PAUL MARINO
05/15/2026
Permit issued — Mechanical Systems
Q01322347-I1-GC-CX
05/12/2026
Filed — Alteration
Q01396292-S1
05/12/2026
Filed — Alteration
Q01396292-I1
05/12/2026
Special inspection requirement — Tenant Protection Plan Compliance
05/12/2026
Special inspection requirement — Tenant Protection Plan Compliance
05/06/2026
Permit issued — Plumbing
Q01322347-S1-PL
05/05/2026
Signed off — Alteration
Q01353019-I1
05/05/2026
Signed off — Alteration
ILLUMINATED NON-ADVERTISING ACCESSORY WALL SIGN - IN PROPERTY LINES - PARKING. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
Q01353020-I1
05/05/2026
Signed off — Alteration
ILLUMINATED NON-ADVERTISING ACCESSORY SIGN ON MARQUEE - IN PROPERTY LINES - WILLETS POINT COMMONS. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
Q01353017-I1
05/05/2026
Signed off — Alteration
ILLUMINATED NON-ADVERTISING ACCESSORY SIGN ON MARQUEE - IN PROPERTY LINES - WILLETS POINT COMMONS. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
Q01353018-I1
05/05/2026
Special inspection requirement — Energy Code Compliance Inspections
05/05/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
05/05/2026
Special inspection requirement — Maintenance information
05/05/2026
Special inspection requirement — Exterior lighting power
04/02/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/01/2026
Permit issued — General Construction
Q01368236-I1-GC
03/25/2026
Filed — New Building
SPRINKLER AND STANDPIPE WORK RELATED TO THE CONSTRUCTION OF A NEW 12 STORY AFFORDABLE HOUSING BUILDING AS PER PLANS FILED HEREWITH.
Q08032504-B2
03/25/2026
Objection raised — Admin
03/18/2026
Filed — Alteration
THIS APPLICATION FILED ONLY TO DELIVER AND INSTALL PHOTOVOLTAIC ARRAYS AND SUPPORT EQUIPMENT ON ROOF. ALL ACTUAL CONSTRUCTION WORK PERFORMED UNDER APPLICATION Q08032504-I1. SOLAR APPLICATION TO BE FILED SEPARATELY. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01368236-I1
03/10/2026
Objection resolved — Addressed
03/09/2026
Permit issued — Sign
Q01353017-I1-SG
03/05/2026
Objection resolved — Addressed
03/03/2026
Objection raised — Cost
03/03/2026
Objection raised — Other
03/02/2026
Signed off — New Building
SPRINKLER AND STANDPIPE WORK RELATED TO THE CONSTRUCTION OF A NEW 12 STORY AFFORDABLE HOUSING BUILDING AS PER PLANS FILED HEREWITH.
Q08032504-S7
03/02/2026
Signed off — New Building
SPRINKLER AND STANDPIPE WORK RELATED TO THE CONSTRUCTION OF A NEW 12 STORY AFFORDABLE HOUSING BUILDING AS PER PLANS FILED HEREWITH.
Q08032504-S8
03/02/2026
Signed off — New Building
SPRINKLER AND STANDPIPE WORK RELATED TO THE CONSTRUCTION OF A NEW 12 STORY AFFORDABLE HOUSING BUILDING AS PER PLANS FILED HEREWITH.
Q08032504-S9
02/25/2026
Permit issued — General Construction
Q08032504-I1-GC
Latest 60 of 274 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedAYA DECOR CORP05/15/2026
DOB NOWPlumbingPermit IssuedKATAN P & H INC05/06/2026
DOB NOWGeneral ConstructionSigned-offHUDSON YARDS CONST II LLC04/01/2026
DOB NOWSignSigned-offACTIVE SIGNS INC03/09/2026
DOB NOWGeneral ConstructionPermit IssuedHUDSON YARDS CONST II LLC02/25/2026
DOB NOWSignSigned-offACTIVE SIGNS INC02/24/2026
DOB NOWSignSigned-offACTIVE SIGNS INC02/24/2026
DOB NOWSignSigned-offACTIVE SIGNS INC02/24/2026
DOB NOWSignSigned-offACTIVE SIGNS INC02/24/2026
DOB NOWStructuralSigned-offHUDSON YARDS CONST II LLC02/20/2026
DOB NOWGeneral ConstructionPermit IssuedHUDSON YARDS CONST II LLC02/02/2026
DOB NOWSprinklersSigned-offRAEL AUTOMATIC SPR.CO INC01/20/2026
DOB NOWStandpipeSigned-offRAEL AUTOMATIC SPR.CO INC01/20/2026
DOB NOWPlumbingSigned-offALMAR PLUMBING & HTG CORP01/16/2026
DOB NOWMechanical SystemsPermit IssuedHUDSON YARDS CONST II LLC11/21/2025
DOB NOWConstruction FenceSigned-offHUDSON YARDS CONST II LLC11/14/2025
DOB NOWProtection and Mechanical MethodsSigned-offS&E BRIDGE & SCAFFOLD LLC09/29/2025
DOB NOWProtection and Mechanical MethodsSigned-offS&E BRIDGE & SCAFFOLD LLC09/26/2025
DOB NOWProtection and Mechanical MethodsSigned-offS&E BRIDGE & SCAFFOLD LLC09/26/2025
DOB NOWGeneral ConstructionPermit IssuedHUDSON YARDS CONST II LLC09/24/2025
DOB NOWSidewalk ShedSigned-offMC SUPERSTRUCTURE INC06/13/2025
DOB NOWSupported ScaffoldSigned-offMC SUPERSTRUCTURE INC06/13/2025
DOB NOWGeneral ConstructionSigned-offHUDSON YARDS CONST II LLC06/03/2025
DOB NOWProtection and Mechanical MethodsSigned-offMC SUPERSTRUCTURE INC05/08/2025
DOB NOWStructuralSigned-offHUDSON YARDS CONST II LLC03/24/2025
DOB NOWFoundationSigned-offHUDSON YARDS CONST II LLC03/20/2025
DOB NOWPlumbingSigned-offALMAR PLUMBING & HTG CORP03/12/2025
DOB NOWGeneral ConstructionPermit IssuedHUDSON YARDS CONST II LLC02/21/2025
DOB NOWStandpipeSigned-offRAEL AUTOMATIC SPR.CO INC02/03/2025
DOB NOWPlumbingSigned-offALMAR PLUMBING & HTG CORP01/30/2025
DOB NOWProtection and Mechanical MethodsSigned-offMC SUPERSTRUCTURE INC01/24/2025
DOB NOWStandpipeSigned-offRAEL AUTOMATIC SPR.CO INC01/15/2025
DOB NOWSprinklersSigned-offRAEL AUTOMATIC SPR.CO INC01/15/2025
DOB NOWPlumbingSigned-offALMAR PLUMBING & HTG CORP12/20/2024
DOB NOWMechanical SystemsPermit IssuedHUDSON YARDS CONST II LLC11/25/2024
DOB NOWConstruction FenceSigned-offHUDSON YARDS CONST II LLC11/13/2024
DOB NOWProtection and Mechanical MethodsSigned-offS&E BRIDGE & SCAFFOLD LLC10/08/2024
DOB NOWProtection and Mechanical MethodsSigned-offS&E BRIDGE & SCAFFOLD LLC10/08/2024
DOB NOWProtection and Mechanical MethodsSigned-offS&E BRIDGE & SCAFFOLD LLC10/08/2024
DOB NOWGeneral ConstructionPermit IssuedHUDSON YARDS CONST II LLC09/23/2024
+ 10 more permits on file
2 projects · most recent 08/26/2026
Ventilation Systems Heating and Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
08/26/2026Permit IssuedAYA DECOR CORPVentilation Systems
Ventilation
Greenheck SQ-160-BX-QD 3,200 CFM · Makeup Air ×2
TBI-CA 1,300 CFM · Kitchen Exhaust ×2
Carrier 45MBCAQ12XA3 14,800 BTU · Ahu ×2
Delta Breeze SLM50 50 CFM · Kitchen Exhaust ×2
03/25/2026Permit IssuedHUDSON YARDS CONST II LLCHeating and Air Conditioning Systems, Heating Systems, Ventilation Systems
Heat / Cool
Hitachi TVAHP144B42S 144,000 BTU · Vrf Outdoor ×24
TVAHP168B42S 168,000 BTU · Vrf Outdoor ×14
TVAHP072B42S 72,000 BTU · Vrf Outdoor ×9
TVAHP096B42S 96,000 BTU · Vrf Outdoor ×3
TVAHP120B42S 120,000 BTU · Heat Pump Outdoor ×3
ACCU-8: TVAHP144B42S, ACCU-9: J2C50287, ACCU-11: J2C50283 144,000 BTU · Heat Pump Outdoor ×1
VAHP036B21S 36,000 BTU · Heat Pump Outdoor ×1
Heating
Aaon RN-015-3-0-K80E-14A 136,500 BTU · Rooftop Unit ×2
RN-011-3-0-K609-12A 45,600 BTU · Rooftop Unit ×1
Ventilation
Aaon RN-015-3-0-K80E-14A 160,100 BTU · Rooftop Unit ×2
RN-011-3-0-K609-12A 86,900 BTU · Rooftop Unit ×1
1 project · most recent 03/25/2026
Sprinkler System
FiledStatusContractorScope
03/25/2026Signed-offRAEL AUTOMATIC SPR.CO INCSprinkler System
2 projects · most recent 08/26/2026
Water/Sanitary Gas Storm
FiledStatusContractorScope
08/26/2026Permit IssuedKATAN P & H INCWater/Sanitary
03/25/2026Signed-offALMAR PLUMBING & HTG CORPGas, Storm, Water/Sanitary
8 projects · most recent 09/23/2026
General Wiring
FiledStatusContractorScope
09/23/2026Permit IssuedJIN ELECTRICAL CONT INC—
06/02/2026Permit IssuedPDI NYC ELECTRIC, LLCGeneral Wiring
05/09/2026Permit IssuedWCK ELECTRIC CORP.General Wiring
04/14/2026CompleteSHELBY ELECTRICAL CORP—
04/09/2026CompleteJAM ELECTRICAL CORP—
03/27/2026Permit IssuedDVM ELECTRICAL SERVICES LGeneral Wiring
01/21/2025CompleteNASH ELECTRIC SERVICES IN—
08/28/2024CompleteHIGH QUALITY ELECTRIC OF—
1 project · most recent 03/25/2026
Steel Concrete Masonry
FiledStatusContractorScope
03/25/2026Permit IssuedHUDSON YARDS CONST II LLCSteel, Concrete, Masonry
1 project · most recent 03/25/2026
Fence
FiledStatusContractorScope
03/25/2026Permit IssuedHUDSON YARDS CONST II LLCFence
▾Field Inspections (DOB CAP) — 16
DateTypeResultReport
04/02/2026Pass-Final CND-Occupancy InspectionPassView ↗
02/24/2026Pass-Final Curb Cut Non-Directive 14PassView ↗
11/12/2025Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
07/29/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/01/2025No Access-Final PL - Up to 3 Requested FloorsNo AccessView ↗
05/20/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
05/20/2025Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
05/07/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
03/13/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
02/21/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/05/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/05/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
06/11/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
06/11/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
03/29/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
03/29/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 150
DateRequirementInspectorRole
08/24/2026FinalGHANENDRA MISHRAprogress
07/14/2026Fire-Resistant Penetrations and Joints—special
07/10/2026Tenant Protection Plan Compliance—special
07/06/2026Sprinkler Systems—special
06/30/2026Electrical motors and elevatorsJOHN MCMONAGLEenergy_progress
06/30/2026HVAC-R and service water piping design and insulationJOHN MCMONAGLEenergy_progress
06/30/2026Ventilation and air distribution systemJOHN MCMONAGLEenergy_progress
06/30/2026Lighting in dwelling unitsJOHN MCMONAGLEenergy_progress
06/30/2026HVAC-R and service water heating equipmentJOHN MCMONAGLEenergy_progress
06/30/2026Exterior lighting powerJOHN MCMONAGLEenergy_progress
06/30/2026HVAC-R and service water heating system controlsJOHN MCMONAGLEenergy_progress
06/30/2026Emergency and Standby Power Systems (Generator)JOHN MCMONAGLEspecial
06/30/2026Mechanical SystemsJOHN MCMONAGLEspecial
06/30/2026Heating SystemsJOHN MCMONAGLEspecial
06/30/2026FinalJOHN MCMONAGLEprogress
06/30/2026Lighting controlsJOHN MCMONAGLEenergy_progress
06/30/2026Duct leakage testing, insulation and designJOHN MCMONAGLEenergy_progress
06/30/2026Maintenance informationJOHN MCMONAGLEenergy_progress
06/30/2026MeteringJOHN MCMONAGLEenergy_progress
06/30/2026Interior lighting powerJOHN MCMONAGLEenergy_progress
06/30/2026Shutoff dampersJOHN MCMONAGLEenergy_progress
06/11/2026Tenant Protection Plan CompliancePAUL MARINOspecial
06/11/2026HVAC-R and service water heating equipmentPAUL MARINOenergy_progress
06/11/2026Energy Code Compliance InspectionsPAUL MARINOprogress
05/12/2026Tenant Protection Plan Compliance—special
Latest 25 of 150.
▾Documents — 461 on file (BIS + DOB NOW)
▸Plans & Drawings63
▸DOB NOWPlans/Sketch63
08/23/2026Q08032504-I1Request digital key ↗
08/23/2026Q08032504-S3Request digital key ↗
08/23/2026Q08032504-S2Request digital key ↗
Showing 3 of 63 on file for this type
▸Applications & Permits11
▸DOB NOWDEP Stormwater Construction Permit7
08/23/2026Q08032504-C4Open ↗
Showing 1 of 7 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION3
02/26/2026421843928Open ↗
05/01/2023421814497Open ↗
02/09/2023421814497Open ↗
▸DOB NOWDEP Stormwater Maintenance Permit/Notice of Termination1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Zoning, Tax Lot & Property Records81
▸DOB NOWRestrictive Declaration/Easement 317
08/23/2026Q08032504-C4Open ↗
08/23/2026Q08032504-C3Open ↗
08/23/2026Q08032504-S5Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWRestrictive Declaration/Easement 117
08/23/2026Q08032504-C4Open ↗
08/23/2026Q08032504-C3Open ↗
08/23/2026Q08032504-S5Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWRestrictive Declaration/Easement 417
08/23/2026Q08032504-S5Open ↗
08/23/2026Q08032504-C3Open ↗
08/23/2026Q08032504-C4Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWRestrictive Declaration/Easement 217
08/23/2026Q08032504-S5Open ↗
08/23/2026Q08032504-C4Open ↗
08/23/2026Q08032504-C3Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWZoning Exhibit form (1-5)5
08/23/2026Q08032504-C4Open ↗
Showing 1 of 5 on file for this type
▸DOB NOWZD1: DOB Zoning Diagram5
08/23/2026Q08032504-C4Open ↗
Showing 1 of 5 on file for this type
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED2
02/06/2026421843928Open ↗
02/07/2023421814497Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Seals & Professional Certifications155
▸DOB NOWProgress Inspector Seal & Signature70
09/25/2026Q01233505-I1Open ↗
09/05/2026Q08032504-S4Open ↗
09/02/2026Q08032504-I1Open ↗
Showing 3 of 70 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature51
09/05/2026Q08032504-S4Open ↗
09/05/2026Q08032504-S4Open ↗
09/05/2026Q08032504-S4Open ↗
Showing 3 of 51 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature34
08/23/2026Q08032504-S1Open ↗
08/23/2026Q08032504-A3Open ↗
08/23/2026Q08032504-A2Open ↗
Showing 3 of 34 on file for this type
▸Trade Schedules & Equipment7
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸DOB NOWStandpipe Alarms Drawings2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸Safety & Tenant Protection10
▸DOB NOWStreet Tree Checklist6
08/23/2026Q08032504-C4Open ↗
Showing 1 of 6 on file for this type
▸DOB NOWStreet Tree Sign Off2
08/23/2026Q08032504-Z6Open ↗
Showing 1 of 2 on file for this type
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWStreet Trees Site Plan1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Environmental & Asbestos36
▸DOB NOWOER: Notice to Proceed20
08/23/2026Q08032504-S5Open ↗
Showing 1 of 20 on file for this type
▸DOB NOWOER: Notice of Satisfaction16
08/23/2026Q08032504-S6Open ↗
08/23/2026Q08032504-S4Open ↗
08/23/2026Q08032504-S5Open ↗
Showing 3 of 16 on file for this type
▸Energy Compliance2
▸DOB NOWPreliminary Commissioning Report Certification2
08/23/2026Q08032504-S6Open ↗
Showing 1 of 2 on file for this type
▸Inspections & Test Reports6
▸DOB NOWConcrete Testing Exception Report2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸DOB NOWSOIL REPORT2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸DOB NOWTR4 Test Report and Plot Diagram1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWTR5 Test Report1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Approvals, Objections & Sign-offs53
▸DOB NOWDesign Commission Approval City Owned (Exterior Work)33
08/23/2026Q08032504-C4Open ↗
08/23/2026Q08032504-C3Open ↗
Showing 2 of 33 on file for this type
▸DOB NOWDesign Commission Sign Off City Owned (Exterior Work)13
08/23/2026Q08032504-S4Open ↗
08/23/2026Q08032504-Z6Open ↗
08/23/2026Q08032504-Z1Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter6
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 6 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION1
01/17/2023421814497Open ↗
▸Filing & Intake Forms4
▸BISEFILING COVER SHEET3
02/26/2026421843928Open ↗
05/01/2023421814497Open ↗
01/17/2023421814497Open ↗
▸BISADDITIONAL INFORMATION1
02/21/2023421814497Open ↗
▸Other Documents33
▸DOB NOWFlood Plan Emergency Temporary Flood Shields8
08/23/2026Q08032504-I1Open ↗
08/23/2026Q08032504-A4Open ↗
08/23/2026Q08032504-B1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSite Survey: Initial6
08/23/2026Q08032504-C4Open ↗
Showing 1 of 6 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone6
08/23/2026Q08032504-C4Open ↗
Showing 1 of 6 on file for this type
▸DOB NOWProperty Ownership Certification5
08/23/2026Q08032504-I1Open ↗
08/23/2026Q08032504-B1Open ↗
08/23/2026Q08032504-C4Open ↗
Showing 3 of 5 on file for this type
▸BISRECORDS MGMT FEE PAYMENT RECEIPT2
02/06/2026421843928Open ↗
02/07/2023421814497Open ↗
▸DOB NOWAdjoining Owners Notification2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸DOB NOWFEMA Elevation Certificate (086-0-33)/Flood Proofing Certificate (086-0-34)2
08/23/2026Q08032504-Z6Open ↗
Showing 1 of 2 on file for this type
▸BISVERIFY DOB PLAN NAMING STANDARD IS MET1
02/06/2026421843928Open ↗
▸BISPLOT DIAGRAM1
02/07/2023421814497Open ↗