Office only, 2-6 stories
141 WEST BROADWAY
MANHATTAN · BIN 1001614
💬 Discuss this project
1890Year Built
3Stories
O2Building Class
C6-2AZoning
2,500 sfGross Floor Area
2Units
1 Open Violation ▸FDNY Report ↗
Office only, 2-6 stories · Owner of record: THREE REDDY LLC · 833 sf lot · 3 FAR built · Flood zone X500
Locations of Work
ArchitectureMechanicalPlumbingGeneral
Permit Issued — active, not yet Signed-off
Roof5p · 3 filings · 20 docs
Floor 3Under Construction14p · 1 filing · 15 docs
Floor 2Under Construction10p · 1 filing · 15 docs
Floor 1
Cellar1p · 1 filing · 19 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
THREE REDDY LLC308/29/2026
JOAN PANTZER TRUST1107/08/2026
A O I CONSTRUCTION103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JACK GREEN ASSOCIATES106/26/2026
MM ARCHITECT PC206/17/2026
CHARLES G. MICHEL ENGINEERING, PC.501/11/2023
DAVID BUCOVY ARCHITECT105/02/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
DAVID BUCOVY ARCHITECT103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
COMPACT HVACR LLCGeneral Contractor303/21/2026
AMCORE I INCGeneral Contractor107/08/2026
COOPER WORKS INCGeneral Contractor107/08/2026
MKSSKR CONSULTING SERVICEGeneral Contractor107/09/2026
DJC CORPPlumbing107/08/2026
OSSO PLUMBING & HEATINGPlumbing107/25/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MM ARCHITECT PC3934106/17/2026
CHARLES G MICHEL ENGINEER2871401/11/2023
DAVID BUCOVY ARCHITECT915105/02/2022
Building Lifecycle
All (60)Filed (9)Permit Issued (6)Signed Off (4)Violation (3)Inspection (1)Objection (12)Special Inspection (25)
07/24/2026
Permit issued — Plumbing
M01395559-S4-PL
07/23/2026
Objection resolved — Addressed
07/07/2026
Permit issued — General Construction
M01395559-I1-GC
07/01/2026
Objection resolved — Addressed
06/29/2026
Objection raised — Scope
06/29/2026
Objection resolved — Addressed
06/26/2026
Filed — Alteration
MECHANICAL MODIFICATIONS AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01395559-S3
06/26/2026
Objection resolved — Addressed
06/25/2026
Objection raised — Other
06/25/2026
Objection raised — Scope
06/25/2026
Objection raised — Admin
06/17/2026
Filed — Alteration
MECHANICAL MODIFICATIONS AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01395559-S4
06/17/2026
Filed — Alteration
MECHANICAL MODIFICATIONS AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01395559-I1
05/20/2026
Special inspection requirement — Fire-Resistance Rated Construction
Matt Markowitz
05/20/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Matt Markowitz
04/30/2026
Special inspection requirement — Final
Matt Markowitz
02/13/2023
Signed off — Alteration
This alteration is being filed to replace a roof hatch with a larger roof hatch.
M00710491-I1
02/02/2023
Signed off — Alteration
THE REPLACEMENT OF THE EXISTING SPLIT SYSTEM A/C AND HEATING UNITS; NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00621432-I1
02/02/2023
Special inspection requirement — Maintenance information
Charles Michel
02/02/2023
Special inspection requirement — HVAC-R and service water heating equipment
Charles Michel
02/02/2023
Special inspection requirement — Mechanical Systems
Charles Michel
02/02/2023
Special inspection requirement — Final
Charles Michel
02/02/2023
Special inspection requirement — HVAC-R and service water heating system controls
Charles Michel
02/02/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Charles Michel
01/11/2023
Filed — Alteration
THE REPLACEMENT OF THE EXISTING SPLIT SYSTEM A/C AND HEATING UNITS; NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00621432-P2
01/09/2023
Special inspection requirement — Mechanical Systems
Charles Michel
01/09/2023
Special inspection requirement — Final
Charles Michel
01/09/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Charles Michel
01/09/2023
Special inspection requirement — HVAC-R and service water heating equipment
Charles Michel
01/09/2023
Special inspection requirement — Maintenance information
Charles Michel
01/09/2023
Special inspection requirement — HVAC-R and service water heating system controls
Charles Michel
12/13/2022
Signed off — Alteration
THE ALTERATION TO THE EXISTING GAS PIPING SYSTEM TO RECONNECT REPLACED ROOFTOP PACKAGED UNIT
M00609504-I1
12/12/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
11/10/2022
Permit issued — Plumbing
M00609504-I1-PL
11/09/2022
Signed off — Alteration
THE REPLACEMENT OF EXISTING ROOF MOUNTED AC/ HEAT UNIT; NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00609410-I1
10/06/2022
Permit issued — Mechanical Systems
M00621432-I1-MS
09/20/2022
Permit issued — Mechanical Systems
M00609410-I1-MS
05/23/2022
Permit issued — General Construction
M00710491-I1-GC
05/06/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
david bucovy
05/05/2022
Objection raised — Accessibility
05/05/2022
Objection resolved — Addressed
05/05/2022
Objection raised — Admin
05/05/2022
Objection resolved — Addressed
05/02/2022
Filed — Alteration
This alteration is being filed to replace a roof hatch with a larger roof hatch.
M00710491-I1
03/31/2022
Special inspection requirement — Fire-Resistance Rated Construction
david bucovy
03/31/2022
Special inspection requirement — Final
david bucovy
03/31/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
david bucovy
03/03/2022
Filed — Alteration
THE REPLACEMENT OF THE EXISTING SPLIT SYSTEM A/C AND HEATING UNITS; NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00621432-P1
11/03/2021
Filed — Alteration
THE REPLACEMENT OF THE EXISTING SPLIT SYSTEM A/C AND HEATING UNITS; NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00621432-I1
10/29/2021
Filed — Alteration
THE ALTERATION TO THE EXISTING GAS PIPING SYSTEM TO RECONNECT REPLACED ROOFTOP PACKAGED UNIT
M00609504-I1
10/29/2021
Filed — Alteration
THE REPLACEMENT OF EXISTING ROOF MOUNTED AC/ HEAT UNIT; NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00609410-I1
10/11/2021
Special inspection requirement — Final
Charles Michel
10/11/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
Charles Michel
10/11/2021
Special inspection requirement — Mechanical Systems
Charles Michel
10/11/2021
Special inspection requirement — Maintenance information
Charles Michel
10/11/2021
Special inspection requirement — HVAC-R and service water heating equipment
Charles Michel
10/11/2021
Special inspection requirement — HVAC-R and service water heating system controls
Charles Michel
01/24/1995
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/24/1995
Violation issued (DOB, open)
VP-VIOLATION UNSERVED ECB-ACTIVE
05/26/1989
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedOSSO PLUMBING & HEATING07/24/2026
DOB NOWGeneral ConstructionPermit IssuedMKSSKR CONSULTING SERVICE07/07/2026
DOB NOWPlumbingSigned-offDJC CORP11/10/2022
DOB NOWMechanical SystemsSigned-offCOOPER WORKS10/06/2022
DOB NOWMechanical SystemsSigned-offCOMPACT HVACR LLC09/20/2022
DOB NOWGeneral ConstructionSigned-offAMCORE I INC05/23/2022
1 project · most recent 06/26/2026
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
06/26/2026Permit IssuedMKSSKR CONSULTING SERVICEAir Conditioning Systems
Cooling
Fujitsu AUUA009KSA1 600 tons · Vrf Indoor ×6
A0UK36SSAN7 3 tons · Condensing Unit ×2
1 project · most recent 06/26/2026
Water/Sanitary
FiledStatusContractorScope
06/26/2026Permit IssuedOSSO PLUMBING & HEATINGWater/Sanitary
2 projects · most recent 10/25/2022
HVAC Wiring General Wiring
FiledStatusContractorScope
10/25/2022Permit IssuedDELTA PHASE ELEC'L CORP.HVAC Wiring
10/24/2020CompleteOM ELECTRIC, INCGeneral Wiring
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
12/12/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 25
DateRequirementInspectorRole
05/20/2026Fire-Resistance Rated ConstructionMatt Markowitzprogress
05/20/2026Fire-Resistant Penetrations and JointsMatt Markowitzspecial
04/30/2026FinalMatt Markowitzprogress
02/02/2023Maintenance informationCharles Michelenergy_progress
02/02/2023HVAC-R and service water heating equipmentCharles Michelenergy_progress
02/02/2023Mechanical SystemsCharles Michelspecial
02/02/2023FinalCharles Michelprogress
02/02/2023HVAC-R and service water heating system controlsCharles Michelenergy_progress
02/02/2023HVAC-R and service water piping design and insulationCharles Michelenergy_progress
01/09/2023Mechanical SystemsCharles Michelspecial
01/09/2023FinalCharles Michelprogress
01/09/2023HVAC-R and service water piping design and insulationCharles Michelenergy_progress
01/09/2023HVAC-R and service water heating equipmentCharles Michelenergy_progress
01/09/2023Maintenance informationCharles Michelenergy_progress
01/09/2023HVAC-R and service water heating system controlsCharles Michelenergy_progress
05/06/2022Structural Stability – Alterations of existing buildingsdavid bucovyspecial
03/31/2022Fire-Resistance Rated Constructiondavid bucovyprogress
03/31/2022Finaldavid bucovyprogress
03/31/2022Fire-Resistant Penetrations and Jointsdavid bucovyspecial
10/11/2021FinalCharles Michelprogress
10/11/2021HVAC-R and service water piping design and insulationCharles Michelenergy_progress
10/11/2021Mechanical SystemsCharles Michelspecial
10/11/2021Maintenance informationCharles Michelenergy_progress
10/11/2021HVAC-R and service water heating equipmentCharles Michelenergy_progress
10/11/2021HVAC-R and service water heating system controlsCharles Michelenergy_progress
▾Documents — 57 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
09/03/2026M00609410-I1Request digital key ↗
09/03/2026M00609504-I1Request digital key ↗
09/03/2026M00621432-P1Request digital key ↗
Showing 3 of 9 on file for this type
▸Applications & Permits9
▸DOB NOWLPC Approval/Permit9
09/03/2026M00609410-I1Open ↗
09/03/2026M00621432-P1Open ↗
09/03/2026M00621432-P2Open ↗
Showing 3 of 9 on file for this type
▸Seals & Professional Certifications25
▸DOB NOWProgress Inspector Seal & Signature10
08/31/2026M00621432-P2Open ↗
08/31/2026M00621432-P2Open ↗
08/30/2026M00710491-I1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature9
09/03/2026M00609410-I1Open ↗
09/03/2026M00621432-I1Open ↗
09/03/2026M00621432-P1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
08/31/2026M00621432-P2Open ↗
08/30/2026M00710491-I1Open ↗
08/30/2026M00710491-I1Open ↗
Showing 3 of 6 on file for this type
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
09/03/2026M00609410-I1Open ↗
09/03/2026M00621432-P2Open ↗
09/03/2026M00621432-P1Open ↗
Showing 3 of 9 on file for this type
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis.2
09/03/2026M00609410-I1Open ↗
09/03/2026M00621432-I1Open ↗
▸Filing & Intake Forms2
▸DOB NOWAI1 Form (from plan PDF)2
08/16/2026M00621432-P1Open ↗
08/16/2026M00621432-P2Open ↗
▸Other Documents1
▸DOB NOWProof of Historic Building1
08/13/2026M00710491-I1Open ↗