HPD04/29/2026(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
ECB12/29/2022I OBSERVED SIDEWALK SHED(SWS) WITH SUPPORTED SCAFFOLD(SF) ON TOP AT EXP1. SWS HAS 1 POST ON TOP OF A ROTTED MUDSILL(BC3307.6.4.10) AND DOES NOT HAVE THE REQUIRED 8F MIN HEIGHT CLEARANCE ABOVE MAIN ENTRANCES(BC3$8K due
ECB05/17/2022UNAPPROVED UNSAFE UNSUITABLE ELECTRICAL EQUIPMENT DEVICES APPARATUS APPLIANCES MATERIALS OR WIRING IN USE EXPOSED ELECTRICAL WIRING IN SIDEWALKSHED SEAL TIGHT IN EXCESS IN SWS COMPLY W/EC CODE$4K due
DOB02/24/2017VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
DOB08/02/2016FM BLDG.BLDG IS LEANING TOWARDS EXP#2 EXCESSIVELY.FRONT BRICK FACADE WALL SEVERELY CRACKED.INTERIOR FLRS ARE SLOPING DOWN TOWARDS EXP#2 REMEDY:OWNER TO IMMED ENGAGE NYS LIC PE TO EVALUATE ENTIRE BLDG.NOTIFY NYC DOB IMMED OF UNSAFE CONDITIONS,OBTAIN PERMIT FOR REPAIR,START REPAIR WORK NO LATER THAN 8/31/16
HPD11/02/2015SECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING MINIMUM REQUIRED 100 WATTS (LIGHT FIXTURE PRESENT) AT FRONT AREAWAY
DOB03/01/2013VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT
DOB12/31/2009V-DOB VIOLATION - ACTIVE
DOB03/19/2003V-DOB VIOLATION - ACTIVE
ECB06/05/2023AT THE TIME OF MY INSPECTION RESPONDING TO COMPLAINT OBSERVED SUPPORTED SCAFFOLD APPROXIMATELY 55 FEET HIGH AT EXP#1. AFTER REVIEW DEPARTMENT RECORDS (BIS AND DOB NOW) REVEAL THAT THERE WERE NO PERMIT. FAILURENothing owed — awaiting certificate of correction
ECB06/05/2023AT THE TIME OF MY INSPECTION RESPONDING TO COMPLAINT I OBSERVED APPROXIMATELY 20 FT OF SIDEWALK SHED AT EXP#1 WAS NOT PROVIDED WITH ILLUMINATED LIGHTING AS REQUIRE (BC 3307.6.4.8) ON THE UNDERSIDE OF SIDEWALK SNothing owed — awaiting certificate of correction
ECB06/05/2023AT THE TIME OF MY INSPECTION RESPONDING TO COMPLAINT OBSERVED SIDEWALK SHED AT EXP#1. AFTER REVIEW DEPARTMENT RECORDS (BIS AND DOB NOW) REVEAL THAT THERE WERE NO PERMIT. FAILURE TO PROVIDE AND MAINTAIN PERMIT ANothing owed — awaiting certificate of correction
ECB12/29/2022I OBSERVED 5 STORY, 55F HIGH BUILDINGS, WITH SIDEWALK SHED(SWS) AND SUPPORTED SCAFFOLD(SF) ON TOP AT EXP1. NO PERMITS OBTAINED EITHER FOR THE SWS NOR FOR THE SF.Nothing owed — awaiting certificate of correction
ECB06/08/2022FAILURE TO OBTAIN A PERMIT PRIOR TO INSTALLATION/USE OF TEMPORARY CONSTRUCTION EQUIPMENT.AT THE TIME OF INSPECTION,OBSERVED SIDEWALK SHED STILL ERECTED AT SITE BY EXPOSURE#1 UNDER JOB#140649056 WITH PERMIT#1406Nothing owed — awaiting certificate of correction
ECB04/18/2022FAILURE TO SECURE SUPPORT RACEWAYS CABLE ASSEMBLIES BOXES CABINETS FITTINGS LIGHTING RACEWAY IN SIDEWALKSHED NOT PROPERLY SUPPORTED SECURE SUPPORT PER ECNothing owed — awaiting certificate of correction
ECB09/13/2018WORK WITHOUT A PERMIT. NOTE: AT TIME O FINSPECTION I OBSERVED SUPPORTED SCAFFOLD IN PLACE WITHOUT VALID PERMIT. REMEDY: COMPLY WITH CODE OBTAIN PERMIT.Nothing owed — awaiting certificate of correction
ECB09/08/2016FAILURE TO MAINTAIN. FIVE STORY MASONRY BLDG HAS SEPERATING & LOOSE BRICK @ 5TH FLR FACADE. SIDEWALK SHED PROVIDED. REM: MAINTAIN BLDG.Nothing owed — awaiting certificate of correction
ECB07/08/2016FAILURE TO MAINTAIN BUILDING.NOTED:5 STORY MASONRY BUILDING WITH SEPARATING &LOOSE BRICK & MASONRY WORK IS OUT OF PLUMB APPROX.8'&LEANING NORTHWARD AGAINST ADJACENT PREMISES.SAME CONDITION AFFECTS A SIGNIFICANothing owed — awaiting certificate of correction
ECB03/26/2016FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.NOTED THE OCCUPIED BLDG IS LEANING TOWARDS EXP2 CRACKS & LOOSE BRICKS THROUGHOUT @ EXP1.REM REPAIR ALL DEFECTSNothing owed — awaiting certificate of correction
ECB10/01/2015FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTE: AT TIME OFINSPECTION THE CONDITION REMAIN THE SAME,BUILDING LEANING TO LEFT EXPO2 AND CRACKS THROUGHOUT THE FRONT, EXP1 AND LOOSE BRICKS ALSO OBSERVEDNothing owed — awaiting certificate of correction
ECB08/05/2015FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. DEFECT NOTED: THE OCCUPIED BLDG IS LEANING TOWARDS EXP#2 ABOUT 8". ALSO OBSERVED CRACKS &LOOSE BRICKS THRU-OUT AT EXP#1. REMEDY: REPAIR ALL DEFECTS. SUBMIT PRONothing owed — awaiting certificate of correction