ECB08/04/2026AGGRAVATED CONDITIONS OBSERVED AT TODAY'S INSPECTION, CONSISTENT WITH VIOLATION #39183753M ISSUED 4/8/2028. AT EXPOSURE 2, SEVERE CRACKS AND SEPARATION REMAIN IN THE MASONRY FACADE. THE EXISTING METAL CORNICE E$6K due
DOB01/09/2026FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. OBSERVED DETERIORATING FACADE ON ALL EXPOSURES. DAMAGED/RUSTED WINDOW LINTELS, RUSTED OUT DEFECTIVE CORNICE, STEP CRACKING, AND CRACKED BRICKS ALL IN MULTIPLE LOCATIONS ON EXPOSURE 1 AND 2. REMEDY: REPAIR AND/OR REPLACE
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
DOB06/29/2021FTM-DEFORMED METAL CORNICE W/PIECES MISSING;LEANING COLMNS@1FL;CRACKED FOOTING @COLUMN@EXP1/2CRNER.@EXP2 CRACKS+DEFORMD FACADE@NORTH-MOST BAY OF WNDWS@MULTI FLRS;.AT EXP3-BULGE OF BRCK WALL.@ROOF:CRCKD+DTRIORATED MEMBRANE.OWNR RTAIN NYS LIC PE&DOB REG CONTRCTR-EVALU ENTRE BLDG+RPAIR UNDR PRMT.FILE REPRS BY 8/1/21.BEGN BY 8/15/21 &COMPLT WRK BY 2/15/22
DOB06/29/2021SEE DOB VIOLATION # 062621FEU10101IK FOR DESCRIPTION OF CONDITIONS OWNR TO IMMED RETAIN NYS LIC PE&SURVYOR TO DVLP&IMPLMNT OPTICL MONITRG CAMPAIGN TO DETERMINE&MONITR MOVMT OF BLDG.PLAN SHALL COMPLY WITH MIN REQUIREMNTS OF RELEVANT SECTNS OF TPPN 10/88.DATA TO BE REVIEWED BY PE +SUBMITTD TO FEU ON A WKLY BASIS.DOB TO BE NOTFIED IMMD MVMT BTWN READ
ECB06/08/2021FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER ATOI NOTED:@FACADE EXP2@1,2,3FL WINDOWS VERT STRUCTURAL CRACKS IN BRICK APPROX12"X4'.ALSO@EXP2 NEAR ROOF SEVERAL DISLODGED BRICKS&@FACADE EXP1 BELOW PARAPET DAMA$3K due
DOB04/12/2021OBSERVED 2-VERTICAL CRACKS ON EXTERIOR BRICK WALL AT EXPO # 02 BOTH SIDE OF LAST ROW WINDOW FROM 1ST FL. TO ROOF LEVEL AND LOOSE BRICKS AT THE CORNER OF EXPO # 02 & 03 UNDER ROOF CORNICE. ALSO OBSERVED METAL CORNICE INSTATE OF DISREPAIR CONDITION WITH MISSING & LOOSE DENTALS AT EXPO # 01 & 02
DOB11/08/2019VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
DOB04/06/2018VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
DOB02/24/2017VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
DOB10/01/2015VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
DOB03/03/2015VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
DOB05/15/2014VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
DOB03/01/2013VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT
DOB12/13/2011VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
DOB12/31/2009V-DOB VIOLATION - ACTIVE
DOB01/19/2007V-DOB VIOLATION - ACTIVE
DOB01/06/2006V-DOB VIOLATION - ACTIVE
DOB01/31/2005V-DOB VIOLATION - ACTIVE
DOB03/26/2002V-DOB VIOLATION - ACTIVE
ECB04/08/2026FAILURE TO MAINTAIN BUILDING WALLS/APPURTENANCES. AT TIME OF INSPECTION OBSERVED AT EXPOSURE#2 (COLLISTER STREET) SEVERE CRACKS AT MASONRY FACADE WITH SEVERE SEPARATION. ALSO EXISTING METAL CORNICE HAS SEVERE CHearing held — result not yet published$5K proposed
ECB02/11/2026FAILURE TO SUBMIT CERTIFICATE OF CORRECTION FOR VIOLATION #39150054M ISSUED ON 06/04/2025 FOR FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER, FILE A CERTIFICATE OF CORRECTIONNothing owed — awaiting certificate of correction
ECB07/20/2021FAILURE TO MAINTAIN EXTERIOR OF BUILDING.VERTICAL AND HORIZONTAL CRACKS WITHIN MASONRY DISLODGED BROCK THROUGHOUT FACADE.SIDEWALK SHED PROVIDED.NO WORK BEING DONE.REMEDY:MAINTAIN FACADE PROVIDE NECESSARY REPAIRNothing owed — awaiting certificate of correction
ECB04/12/2021OBSERVED 2-VERTICAL CRACKS ON EXTERIOR BRICK WALL AT EXPO # 02 BOTH SIDE OF LAST ROW WINDOW FROM 1ST FL. TO ROOF LEVEL AND LOOSE BRICKS AT THE CORNER OF EXPO # 02 & 03 UNDER ROOF CORNICE. ALSO OBSERVED METAL CONothing owed — awaiting certificate of correction
ECB06/07/2016B265 AS PER CLASS (B265) 28-303.7 FAILURE TO FILE A COMPLETE BOILER INSPECTION REPORT AS PER DOB RECORDS. SUBMIT A CURRENT BO9 REPORT COR RECT ALL VIOLATING CONDITIONS AND SUBMIT THE CERTIFICATE OF CORRECTIONNothing owed — awaiting certificate of correction
ECB01/31/2016FAILURE TO MAINTAIN BLDG WALL & APPURTENANCES. NOTED: BRICK WORK IS CRACKED FROM GROUND LEVEL UP TO 4TH STY ON WEST SIDE OF BLDG(FACING COLLISTER ST)ALSO METAL CORNICE OS ROTTED & MISSING PIECES AT VARIOUSNothing owed — awaiting certificate of correction
ECB05/21/2003FAILURE TO MAINTAIN DEFECT IS METAL LINTELS ON ALL WINDOWS ARE RUSTED REMEDY: REPAIR DEFECTNothing owed — awaiting certificate of correction