← Back
Over six families without stores
21 MONROE STREET
MANHATTAN · BIN 1003293
💬 Discuss this project
1900Year Built
5Stories
C1Building Class
R7-2Zoning
9,575 sfGross Floor Area
20Units
Rent Stabilized4 Open Violations ▸FDNY Report ↗
Over six families without stores · Owner of record: TAI LEE CORP · 2,538 sf lot · 3.77 FAR built · Flood zone X
Locations of Work
ArchitectureMechanical
Cellar3p · 1 filing · 7 docs
Nothing on file for this building.
Building Lifecycle
All (25)Filed (2)Permit Issued (2)Signed Off (2)Violation (10)Inspection (2)Objection (4)Special Inspection (3)
11/06/2025
Signed off — Alteration
Remove all partition, bathroom and kitchen fixtures. Restore cellar space to storage as per CO#53868. Address violations 39148894M and 39148893K. No Change in use, egress and occupancy.
M01237912-S1
11/06/2025
Signed off — Alteration
Remove all partition, bathroom and kitchen fixtures. Restore cellar space to storage as per CO#53868. Address violations 39148894M and 39148893K. No Change in use, egress and occupancy.
M01237912-I1
10/20/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
10/20/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
09/19/2025
Permit issued — Plumbing
M01237912-S1-PL
08/26/2025
Permit issued — General Construction
M01237912-I1-GC
07/04/2025
Objection resolved — Addressed
07/03/2025
Objection raised — Cost
07/03/2025
Objection raised — Plumbing
07/03/2025
Objection resolved — Addressed
06/17/2025
Filed — Alteration
Remove all partition, bathroom and kitchen fixtures. Restore cellar space to storage as per CO#53868. Address violations 39148894M and 39148893K. No Change in use, egress and occupancy.
M01237912-S1
06/17/2025
Filed — Alteration
Remove all partition, bathroom and kitchen fixtures. Restore cellar space to storage as per CO#53868. Address violations 39148894M and 39148893K. No Change in use, egress and occupancy.
M01237912-I1
06/07/2025
Special inspection requirement — Tenant Protection Plan Compliance
MING WAI WONG
06/07/2025
Special inspection requirement — Tenant Protection Plan Compliance
MING WAI WONG
06/07/2025
Special inspection requirement — Final
MING WAI WONG
05/23/2025
Violation issued (ECB, closed)
Construction
05/23/2025
Violation issued (ECB, closed)
Construction
05/23/2025
Violation issued (FDNY_NOV, closed)
11/25/2013
Violation issued (HPD, closed)
C
04/09/2013
Violation issued (HPD, closed)
B
12/31/2009
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/06/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/10/1997
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
08/29/1995
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/18/1993
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ARISTOCRAT MANAGEMENT704/09/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MW PROFESSIONAL ENGINEERING, P.C.206/17/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
WATSON'S PLUMBING HEATINGGeneral Contractor104/09/2026
WATSON'S PLBG, HTG, & BDGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MW PROFESSIONAL ENGINEERI570206/17/2025
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offWATSON'S PLBG, HTG, & BDG09/19/2025
DOB NOWGeneral ConstructionSigned-offWATSON'S PLUMBING HEATING08/26/2025
BISOTISSUEDHI-BUILD CONSTRUCTION COR02/20/2020
BISBLISSUEDT&C FUEL CO INC12/21/2006
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
10/20/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
10/20/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
06/07/2025Tenant Protection Plan ComplianceMING WAI WONGspecial
06/07/2025Tenant Protection Plan ComplianceMING WAI WONGspecial
06/07/2025FinalMING WAI WONGprogress
▾Documents — 25 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/23/2026M01237912-I1Request digital key ↗
08/23/2026M01237912-S1Request digital key ↗
▸Applications & Permits3
▸BISWORK PERMIT APPLICATION2
02/20/2020140880401Open ↗
12/10/2019140880401Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
12/10/2019140880401Open ↗
▸Seals & Professional Certifications8
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/23/2026M01237912-S1Open ↗
08/23/2026M01237912-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/24/2026M01237912-S1Open ↗
08/24/2026M01237912-I1Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
12/10/2019140880401Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
12/10/2019140880401Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
12/10/2019140880401Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/24/2026M01237912-I1Open ↗
▸Safety & Tenant Protection1
▸BISTENANT PROTECTION PLAN AND NOTES1
12/10/2019140880401Open ↗
▸Environmental & Asbestos1
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
12/10/2019140880401Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
09/11/2020140880401Open ↗
12/10/2019140880401Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
09/11/2020140880401Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
12/10/2019140880401Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
09/11/2020140880401Open ↗
12/10/2019140880401Open ↗
▸Approvals, Objections & Sign-offs2
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
09/11/2020140880401Open ↗
09/11/2020140880401Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
12/10/2019140880401Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
12/10/2019140880401Open ↗