← Back
Miscellaneous one family
24 WEST 10 STREET
MANHATTAN · BIN 1009474
💬 Discuss this project
1856Year Built
5Stories
A9Building Class
R6Zoning
5,774 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Miscellaneous one family · Owner of record: 24 WEST 10TH STREET TOWNHOUSE LLC · 1,960 sf lot · 2.95 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction12p · 1 filing · 20 docs
PenthouseUnder Construction11p · 1 filing · 20 docs
Floor 5Under Construction44p · 1 filing · 20 docs
Floor 4Under Construction43p · 1 filing · 20 docs
Floor 3Under Construction45p · 1 filing · 20 docs
Floor 2Under Construction43p · 1 filing · 20 docs
Floor 1Under Construction41p · 1 filing · 20 docs
CellarUnder Construction10p · 1 filing · 20 docs
Sub-BasementUnder Construction36p · 1 filing · 20 docs
1 job · most recent 04/22/2025
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
04/22/2025Permit IssuedAAMWAY SERVICE CO INCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric PEFY-P12NMAU-E4 12,000 BTU · Vrf Indoor ×5
PVFY-P12NAMU-E1 12,000 BTU · Vrf Indoor ×4
MXZ-SM72TAM-U1 72,000 BTU · Heat Pump Outdoor ×2
PEFY-P08NMAU-E4 8,000 BTU · Vrf Indoor ×1
PEFY-P18NMAU-E5 18,000 BTU · Vrf Indoor ×1
PVFY-P08NAMU-E1 8,000 BTU · Vrf Indoor ×1
PVFY-P18NAMU-E1 18,000 BTU · Vrf Indoor ×1
Ventilation
Panasonic FV-0511VF1 50 CFM · Exhaust Fan ×10
Aldes E-190 165 CFM · Erv ×1
1 job · most recent 04/22/2025
Sprinkler System
FiledStatusContractorScope
04/22/2025Permit IssuedMASTER PLBG AND HTG INCSprinkler System
1 job · most recent 04/22/2025
Gas Storm Water/Sanitary
FiledStatusContractorScope
04/22/2025Permit IssuedARCON PLBG SOLUTIONSGas, Storm, Water/Sanitary
3 jobs · most recent 02/05/2026
General Wiring
FiledStatusContractorScope
02/05/2026Permit IssuedFINESSE ELECTRIC LLCGeneral Wiring
09/22/2025Permit IssuedHIGH QUALITY ELEC.OF NYC—
05/27/2025Permit IssuedFRACCAVENTO ELEC. CORPGeneral Wiring
1 job · most recent 04/22/2025
Steel
FiledStatusContractorScope
04/22/2025Permit IssuedAAMWAY SERVICE CO INCSteel
Building Lifecycle
All (59)Filed (7)Permit Issued (17)Violation (6)Inspection (6)Objection (18)Special Inspection (5)
09/17/2026
Permit issued — Sidewalk Shed
M01290028-I1-SF
09/17/2026
Permit issued — Supported Scaffold
M01290028-I1-SH
08/17/2026
Permit issued — Mechanical Systems
M01145276-S3-MS
07/21/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
07/10/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
05/21/2026
Permit issued — Sprinklers
M01145276-S5-EW-SP
05/14/2026
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
04/27/2026
Permit issued — Plumbing
M01145276-S4-PL
04/23/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/09/2026
Permit issued — General Construction
M01145276-I1-GC
01/09/2026
Permit issued — Foundation
M01145276-S1-FO
01/09/2026
Permit issued — Structural
M01145276-S2-ST
11/13/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/29/2025
Permit issued — Foundation
M01145276-S1-FO
09/19/2025
Permit issued — Supported Scaffold
M01290028-I1-SF
09/19/2025
Permit issued — Supported Scaffold
M01290028-I1-SH
09/18/2025
Filed — Alteration
M01290028-I1
09/12/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/11/2025
Permit issued — Mechanical Systems
M01145276-S3-MS
05/23/2025
Permit issued — Mechanical Systems
M01145276-S3-MS
05/14/2025
Permit issued — Sprinklers
M01145276-S5-EW-SP
05/13/2025
Permit issued — Plumbing
M01145276-S4-PL
05/05/2025
Objection resolved — Addressed
05/01/2025
Objection raised — Cost
04/28/2025
Permit issued — General Construction
M01145276-I1-GC
04/28/2025
Permit issued — Structural
M01145276-S2-ST
04/22/2025
Filed — Alteration CO
FILING HEREWITH SPRINKLER WORK AS PER PLANS.
M01145276-S3
04/22/2025
Objection resolved — Addressed
04/22/2025
Objection resolved — Addressed
04/22/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
GAETANO D'ANTONIO
04/14/2025
Objection resolved — Addressed
04/14/2025
Objection resolved — Addressed
04/14/2025
Objection resolved — Addressed
03/17/2025
Objection resolved — Addressed
03/17/2025
Objection resolved — Addressed
03/17/2025
Objection resolved — Addressed
03/03/2025
Objection raised — Other
03/03/2025
Objection raised — Admin
03/03/2025
Objection raised — Plumbing
03/03/2025
Objection raised — Plumbing
03/03/2025
Objection raised — Cost
02/28/2025
Filed — Alteration CO
FILING HEREWITH SPRINKLER WORK AS PER PLANS.
M01145276-S4
02/28/2025
Filed — Alteration CO
FILING HEREWITH SPRINKLER WORK AS PER PLANS.
M01145276-S5
02/28/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
GAETANO D'ANTONIO
12/05/2024
Filed — Alteration CO
FILING HEREWITH SPRINKLER WORK AS PER PLANS.
M01145276-S1
12/05/2024
Objection raised — Admin
12/05/2024
Objection raised — Structural
12/05/2024
Objection raised — Admin
12/04/2024
Filed — Alteration CO
FILING HEREWITH SPRINKLER WORK AS PER PLANS.
M01145276-S2
12/02/2024
Filed — Alteration CO
FILING HEREWITH SPRINKLER WORK AS PER PLANS.
M01145276-I1
11/20/2024
Special inspection requirement — Mechanical Systems
GAETANO D'ANTONIO
11/20/2024
Special inspection requirement — Final
GAETANO D'ANTONIO
11/20/2024
Special inspection requirement — Sprinkler Systems
GAETANO D'ANTONIO
12/20/2023
Violation issued (FDNY_NOV, closed)
11/12/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/19/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/08/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/31/1990
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/31/1990
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
KINGS GROUP NY609/18/2026
24 WEST 10TH STREET TOWNHOUSE LLC403/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/10/2023$18.5M—— → —$3,204/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
HARPREET SINGH109/18/2025
D'ANTONIO CONSULTING ENGINEERS304/22/2025
AGENCIE GROUP LLC212/05/2024
ELIZABETH ROBERTS ARCHITECTURE & DE112/02/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JM ZONING, LLC.1203/21/2026
KMA DESIGNS LLC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
THINK CONSTRUCTION LLCGeneral Contractor607/08/2026
AAMWAY SERVICE CO INCGeneral Contractor308/26/2026
KINGS GROUP NY CORPGeneral Contractor309/18/2026
ARCON PLBG SOLUTIONSPlumbing207/08/2026
MASTER PLBG AND HTG INCFire Protection207/08/2026
MICHAL LIWAKElectrical103/21/2026
HIGH QUALITY ELEC.OF NYCElectrical103/22/2026
ANGELO ARFANISElectrical103/21/2026
ALEXANDER EUGENEElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
D'ANTONIO CONSULTING ENGI931304/22/2025
AGENCIE GROUP LLC2803212/05/2024
ALAN MARGOLIN & ASSOC423112/02/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSidewalk ShedPermit IssuedBNL CONSTRUCTION09/17/2026
DOB NOWSupported ScaffoldPermit IssuedKINGS GROUP NY CORP09/17/2026
DOB NOWMechanical SystemsPermit IssuedAAMWAY SERVICE CO INC08/17/2026
DOB NOWSprinklersPermit IssuedMASTER PLBG AND HTG INC05/21/2026
DOB NOWPlumbingPermit IssuedARCON PLBG SOLUTIONS04/27/2026
DOB NOWGeneral ConstructionPermit IssuedTHINK CONSTRUCTION LLC01/09/2026
DOB NOWFoundationPermit IssuedTHINK CONSTRUCTION LLC01/09/2026
DOB NOWStructuralPermit IssuedTHINK CONSTRUCTION LLC01/09/2026
DOB NOWFoundationPermit IssuedTHINK CONSTRUCTION LLC09/29/2025
DOB NOWSupported ScaffoldPermit IssuedKINGS GROUP NY CORP09/19/2025
DOB NOWSupported ScaffoldPermit IssuedKINGS GROUP NY CORP09/19/2025
DOB NOWMechanical SystemsPermit IssuedAAMWAY SERVICE CO INC08/11/2025
DOB NOWMechanical SystemsPermit IssuedAAMWAY SERVICE CO INC05/23/2025
DOB NOWSprinklersPermit IssuedMASTER PLBG AND HTG INC05/14/2025
DOB NOWPlumbingPermit IssuedARCON PLBG SOLUTIONS05/13/2025
DOB NOWGeneral ConstructionPermit IssuedTHINK CONSTRUCTION LLC04/28/2025
DOB NOWStructuralPermit IssuedTHINK CONSTRUCTION LLC04/28/2025
BISSPISSUEDFLINT MECHANICAL CORP08/16/2021
BISMHISSUEDFOUR STAR AIR CON'D CO LL06/23/2020
BISMHISSUEDFOUR STAR AIR CON'D CO LL03/16/2020
BISMHISSUEDFOUR STAR AIR CON'D CO LL12/03/2019
BISPLISSUEDG & J PLMBNG AND HTG INC12/10/2018
BISMHISSUEDSOHO CUSTOM INTERIORS LTD01/09/2001
BISEQISSUEDROCKLEDGE SCAFFOLD CORP04/05/2000
BISPLISSUEDTILOS PLBG & HTG CORP09/01/1999
BISEQISSUEDROCKLEDGE SCAFFOLD CORP08/02/1999
BIS—ISSUEDSOHO CUSTOM INTERIORS06/23/1999
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
07/21/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
07/10/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
05/14/2026Pass-Final PL - UndergroundPassView ↗
04/23/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/13/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/12/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
04/22/2025Fire-Resistant Penetrations and JointsGAETANO D'ANTONIOspecial
02/28/2025Fire-Resistant Penetrations and JointsGAETANO D'ANTONIOspecial
11/20/2024Mechanical SystemsGAETANO D'ANTONIOspecial
11/20/2024FinalGAETANO D'ANTONIOprogress
11/20/2024Sprinkler SystemsGAETANO D'ANTONIOspecial
▾Documents — 94 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/25/2026M01145276-S4Request digital key ↗
08/25/2026M01145276-I1Request digital key ↗
08/25/2026M01145276-S2Request digital key ↗
Showing 3 of 7 on file for this type
▸Applications & Permits17
▸BISPLAN / WORK APPROVAL APPLICATION7
07/09/2021102214284Open ↗
03/05/2021140846486Open ↗
10/26/2020140846486Open ↗
Showing 3 of 7 on file for this type
▸BISWORK PERMIT APPLICATION5
08/17/2021102214284Open ↗
03/17/2020140846486Open ↗
12/03/2019140846486Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWLPC Approval/Permit5
08/13/2026M01145276-I1Open ↗
08/13/2026M01145276-S1Open ↗
08/13/2026M01145276-S4Open ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications20
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/25/2026M01145276-S4Open ↗
08/25/2026M01145276-I1Open ↗
08/25/2026M01145276-S1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/26/2026M01145276-S4Open ↗
08/23/2026M01145276-S5Open ↗
08/23/2026M01145276-S3Open ↗
Showing 3 of 4 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
05/02/2019140846486Open ↗
10/11/2018140809383Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
05/02/2019140846486Open ↗
10/11/2018140809383Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
05/02/2019140846486Open ↗
10/11/2018140809383Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
10/10/2019140809383Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
10/26/2020140846486Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/23/2026M01145276-S3Open ↗
▸Trade Schedules & Equipment7
▸BISEQUIPMENT USE PERMITS2
05/25/2021140846486Open ↗
05/11/2021140846486Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
07/19/2019140809383Open ↗
07/16/2019140809383Open ↗
▸BISEQUIPMENT USE APPLICATION/PERMIT2
05/25/2021140846486Open ↗
05/11/2021140846486Open ↗
▸BISSCHEDULE B - PLUMBING1
10/11/2018140809383Open ↗
▸Safety & Tenant Protection3
▸BISTENANT PROTECTION PLAN AND NOTES2
05/02/2019140846486Open ↗
10/11/2018140809383Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026M01145276-I1Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form6
08/25/2026M01145276-S4Open ↗
08/25/2026M01145276-I1Open ↗
08/25/2026M01145276-S1Open ↗
Showing 3 of 6 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
05/02/2019140846486Open ↗
10/11/2018140809383Open ↗
▸Energy Compliance7
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
05/11/2021140846486Open ↗
05/02/2019140846486Open ↗
10/11/2018140809383Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS2
05/02/2019140846486Open ↗
10/11/2018140809383Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
10/10/2019140809383Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
10/10/2019140809383Open ↗
▸Inspections & Test Reports5
▸BISTECHNICAL REPORT: RESPONSIBILITY3
05/11/2021140846486Open ↗
05/02/2019140846486Open ↗
10/11/2018140809383Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026M01145276-S1Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026M01145276-S1Open ↗
▸Approvals, Objections & Sign-offs7
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
12/15/2021102214284Open ↗
05/11/2021140846486Open ↗
10/10/2019140809383Open ↗
▸BISLANDMARKS APPROVAL2
05/02/2019140846486Open ↗
10/11/2018140809383Open ↗
▸BISSUPERSEDING LETTER1
08/17/2021102214284Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
05/25/2021140846486Open ↗
▸Cost, Insurance & Ownership5
▸BISCOST AFFIDAVIT4
05/11/2021140846486Open ↗
10/10/2019140809383Open ↗
05/02/2019140846486Open ↗
Showing 3 of 4 on file for this type
▸BISHIC LICENSE OR AFFIDAVIT1
10/11/2018140809383Open ↗
▸Filing & Intake Forms6
▸BISBOROUGH INTAKE FORM3
08/17/2021102214284Open ↗
10/10/2019140809383Open ↗
07/16/2019140809383Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET2
05/02/2019140846486Open ↗
10/11/2018140809383Open ↗
▸BISADDITIONAL INFORMATION1
07/19/2019140809383Open ↗
▸Other Documents2
▸DOB NOWProperty Ownership Certification1
08/25/2026M01145276-I1Open ↗
▸DOB NOWProof of Historic Building1
08/13/2026M01145276-I1Open ↗