DOB03/20/2024FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB12/01/2023FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
DOB08/02/2023FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB05/02/2023FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB02/02/2023FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB12/01/2022FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
DOB11/02/2022FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB08/02/2022FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB06/01/2022FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB02/02/2022FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB12/01/2021FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
DOB11/02/2021FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB08/02/2021FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB06/02/2021FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB09/02/2020FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB05/02/2019FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
ECB04/15/2024UNLAWFUL ACTS. FAILURE TO COMPLY WITH COMMISSIONER'S ORDER. NOTE: RESPONDENT FAILURE TO COMPLY WITH COMMISSIONER'S ORDER FOR PRIOR SUMMON #35679880Z DATED(01/11/24). AT TIME OF INSPECTION, I OBSERVED AN ACTIVENothing owed — awaiting certificate of correction
ECB01/11/2024FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION.NOTE:AT TIME OF INSPECTION ON ACTIVE PARKING STRUCTURE CONSISTING OF 3 LEVEL(AT GL L-1 & ABOVE GL L-283) OBSERVED CRACK BEAM & SLAB,SPALLING CONCRETE AT LNothing owed — awaiting certificate of correction
ECB01/27/2020INSPECTION CONDUCTED, FOUND THAT JOB #104500149 ISSUED ON 08/04/2006 FOR W/O PERMIT, HOWEVER AT TIME OF INSPECTION OBSERVED WORK 100% COMPLETED WHILE ON NOTICE OF A STOP WORK ORDER., COMPLY WITH STOP WORK ORDERNothing owed — awaiting certificate of correction
ECB09/30/2019FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#35360541J ISSUED ON 11/15/18 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01(D)(2).AN ACCEPTIBLE CERTNothing owed — awaiting certificate of correction
ECB11/23/2018WORK WITHOUT A PERMIT "WORK NOTED" FRONT FACADE FIRST FLOOR ERECTED BUSINESS ACCESSORY SIGN APPROX 5'H X 25' W X 1.5" PROJECTING 5" OUT OF BUIDING WALL WORDING "C.C.RENTAL TRUCKS VAN CARS. 212 239 3333"Nothing owed — awaiting certificate of correction
ECB11/30/2011FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY NOTED : @ GARAGE 2ND 3RD FL EXIT DOORS OBSTRUCTED W/ TIGHT FITTING PARKED CARS, 1ST FL REAR STAIRWAY EXIT DOOR TO ST. OBSTRUCTED W/ ROLL DOWN GATE & SIDEWALK RECYNothing owed — awaiting certificate of correction
ECB02/12/2010FAILURE TO MAINTAIN BLDG IN CODE COMPLAINT MANNER. NOTED: SPALLED PAINT PLASTER & CONCRETE IN THE CEILING AT THE BASEMENT LEVEL. THERE ALSO MARKS OF RUSTING IN THE CEILING INDICATING CORROSION OF STEEL EMDEDDEDNothing owed — awaiting certificate of correction
ECB02/12/2010FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTED: EXIT DOOR & PASSAGEWAY AT 3RD FL NORTH END IS BLOCKED OBSTRUCTED BY PARKED CAR. REMEDY: REMOVE OBSTRUCTION.Nothing owed — awaiting certificate of correction
ECB03/06/2006FAILURE TO MAINTAIN INTERIOR BLDG-HAZARDOUS. DEFECT NOTED: CONCRETE FLR AT 3RD FLR CENTER COMMERCIAL SPACE-PARKING GARAGE APPRX. 8' X 8' COLLAPSED TO 2ND FLR WITH ONE SIDE SAGGING CONCRETE SLAB. ALSO CEILINGS ANothing owed — awaiting certificate of correction
ECB02/01/2005FIRE EXIT DOOR TOTALLY OBSTRUCTED.AUTO ON 2ND FLOOR FRONT TOTALLY OBSTRUCTING FIRE EXIT DOORS CAUSING A HAZARDOUS CONDITION.REMEDY:REMOVE ALL AUTOS FROM FIRE DOOR.Nothing owed — awaiting certificate of correction
ECB07/16/2004FAILURE TO MAINTAIN PARKING IN BASEMENT AT THE CEILING 1ST FL SLAB CRACKED & FAILING CONCRETE BEAM SLAB HAS EXPOSED STEEL REBARS & SPALLING CONCRETE AT VARIOUS LOCATIONS REMEDY:MAINTAIN BUILDING REMOVES & REPAINothing owed — awaiting certificate of correction
ECB03/17/2004FAILURE TO MAINTAIN BUILDING : NOTE (1) AT BASEMENT CEILING - CRACKED CONCRETE AT BEAM ( NEAR FRONT ) SPALLING CONCRETE AT CEILING W/ EXPOSED REBAR & LOOSE CONCRETE (2) AT BASEMENT REAR FIRE PASSAGE CONCRETE CENothing owed — awaiting certificate of correction