Miscellaneous two family
44 JANE STREET
MANHATTAN · BIN 1011436
💬 Discuss this project
1846Year Built
3Stories
B9Building Class
C1-6Zoning
4,240 sfGross Floor Area
2Units
1 Open Violation ▸FDNY Report ↗
Miscellaneous two family · Owner of record: 44 JANE LLC · 1,276 sf lot · 3.32 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Roof9p · 2 filings · 20 docs
Bulkhead1p · 1 filing · 20 docs
Floor 44p · 1 filing · 20 docs
Floor 33p · 2 filings · 20 docs
Floor 25p · 2 filings · 20 docs
Floor 12p · 2 filings · 20 docs
Cellar8p · 2 filings · 20 docs
Basement4p · 2 filings · 20 docs
1 job · most recent 07/25/2024
Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/25/2024——Air Conditioning Systems, Ventilation Systems
Cooling
Daikin RXTQ60TBVJUA 60,000 BTU · Vrf Outdoor ×2
Ventilation
Panasonic FV-05-11VK1 75 CFM · Exhaust Fan ×6
Greenheck SQ-60-VG 50 CFM · Exhaust Fan ×1
SQ-90-VG 200 CFM ×1
SQ-95-VG 250 CFM · Exhaust Fan ×1
Renewaire EV PREMIUM M 250 CFM · Erv ×1
1 job · most recent 04/09/2024
FiledStatusContractorScope
04/09/2024——43 heads
1 job · most recent 07/25/2024
Gas Storm Water/Sanitary
FiledStatusContractorScope
07/25/2024——Gas, Storm, Water/Sanitary
1 job · most recent 11/07/2024
FiledStatusContractorScope
11/07/2024Permit IssuedAPOLLO ELECTRIC USA, INC—
1 job · most recent 07/25/2024
Steel Masonry Wood
FiledStatusContractorScope
07/25/2024——Steel, Masonry, Wood
Building Lifecycle
All (78)Filed (8)Permit Issued (1)Violation (1)Objection (42)Special Inspection (26)
06/23/2026
Objection resolved — Addressed
06/23/2026
Special inspection requirement — Air barrier - visual inspection
06/23/2026
Special inspection requirement — Interior lighting power
06/23/2026
Special inspection requirement — Exterior lighting power
06/23/2026
Special inspection requirement — Lighting in dwelling units
06/23/2026
Special inspection requirement — Insulation placement and R values
06/23/2026
Special inspection requirement — Lighting controls
06/16/2026
Objection raised — Energy
06/15/2026
Objection resolved — Addressed
06/12/2026
Objection raised — Accessibility
05/20/2026
Objection raised — Energy
05/11/2026
Objection raised — Scope
04/30/2026
Objection resolved — Resolved
04/27/2026
Objection resolved — Addressed
12/03/2025
Objection resolved — Addressed
11/24/2025
Objection raised — Other
11/10/2025
Objection resolved — Resolved
11/10/2025
Objection resolved — Addressed
11/10/2025
Objection resolved — Addressed
11/10/2025
Objection resolved — Addressed
11/10/2025
Objection resolved — Addressed
11/10/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
11/10/2025
Special inspection requirement — HVAC-R and service water heating equipment
11/10/2025
Special inspection requirement — HVAC-R and service water heating system controls
10/17/2025
Objection resolved — Addressed
07/30/2024
Objection raised — Other
07/30/2024
Objection raised — Admin
07/30/2024
Objection raised — Other
07/25/2024
Filed — Alteration CO
HEREWITH FILING FOR STRUCUTRAL MODIFICATIONS AS PER PLANS INCLUDING NEW FOUNDATION WALL AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00996727-S4
07/24/2024
Objection resolved — Addressed
06/21/2024
Objection resolved — Addressed
06/10/2024
Objection resolved — Addressed
06/10/2024
Objection resolved — Addressed
06/10/2024
Objection resolved — Addressed
05/14/2024
Objection raised — Other
05/14/2024
Objection raised — Other
05/14/2024
Objection raised — Other
05/14/2024
Objection raised — Other
05/10/2024
Objection raised — Other
05/10/2024
Objection raised — Other
05/10/2024
Objection resolved — Addressed
05/06/2024
Objection raised — Structural
05/06/2024
Objection raised — Admin
05/06/2024
Objection raised — Scope
05/06/2024
Objection raised — Fire_Protection
05/06/2024
Objection raised — Zoning
05/06/2024
Objection raised — Other
04/29/2024
Objection raised — Other
04/23/2024
Filed — Alteration CO
HEREWITH FILING FOR STRUCUTRAL MODIFICATIONS AS PER PLANS INCLUDING NEW FOUNDATION WALL AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00996727-S5
04/22/2024
Filed — Alteration CO
HEREWITH FILING FOR STRUCUTRAL MODIFICATIONS AS PER PLANS INCLUDING NEW FOUNDATION WALL AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00996727-S2
04/22/2024
Filed — Alteration CO
HEREWITH FILING FOR STRUCUTRAL MODIFICATIONS AS PER PLANS INCLUDING NEW FOUNDATION WALL AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00996727-S1
04/22/2024
Special inspection requirement — Footing and Foundation
04/17/2024
Objection raised — Scope
04/17/2024
Objection resolved — Addressed
04/17/2024
Objection raised — Scope
04/17/2024
Objection resolved — Addressed
04/09/2024
Filed — Alteration
44 JANE STREET - NEW INSTALLATION OF A SPRINKLER SYSTEM AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
M01010530-I1
04/05/2024
Filed — Alteration CO
HEREWITH FILING FOR STRUCUTRAL MODIFICATIONS AS PER PLANS INCLUDING NEW FOUNDATION WALL AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00996727-I1
03/20/2024
Special inspection requirement — Fire-Resistance Rated Construction
03/20/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Latest 60 of 78 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
DK103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/31/2022$8.5M—JANE STREET VILLAGE ASSOCIATES LLC → 44 JANE LLC$2,005/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
A DEGREE OF FREEDOM STRUCTURAL ENGI207/25/2024
CES ENGINEERING LLC304/22/2024
POVERO AND COMPANY304/05/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
OUTSOURCE CONSULTANTS, INC.1603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PLANT CONSTRUCTION LLCGeneral Contractor203/21/2026
APOLLO ELECTRIC USA, INCElectrical103/22/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedPLANT CONSTRUCTION LLC12/04/2023
▾Special Inspection Requirements (DOB NOW) — 26
DateRequirementInspectorRole
06/23/2026Air barrier - visual inspection—energy_progress
06/23/2026Interior lighting power—energy_progress
06/23/2026Exterior lighting power—energy_progress
06/23/2026Lighting in dwelling units—energy_progress
06/23/2026Insulation placement and R values—energy_progress
06/23/2026Lighting controls—energy_progress
11/10/2025HVAC-R and service water piping design and insulation—energy_progress
11/10/2025HVAC-R and service water heating equipment—energy_progress
11/10/2025HVAC-R and service water heating system controls—energy_progress
04/22/2024Footing and Foundation—progress
03/20/2024Fire-Resistance Rated Construction—progress
03/20/2024Fire-Resistant Penetrations and Joints—special
03/08/2024Subsurface Investigations (Borings/Test Pits)—special
03/08/2024Underpinning—special
03/08/2024Subgrade Inspections—special
03/08/2024Excavations - Sheeting, Shoring, and Bracing—special
02/29/2024Fire-Resistant Penetrations and Joints—special
02/28/2024Fire-Resistant Penetrations and Joints—special
02/28/2024Masonry—special
02/28/2024Heating Systems—special
02/25/2024Fire-Resistant Penetrations and Joints—special
02/25/2024Sprinkler Systems—special
01/26/2024Mechanical Systems—special
01/26/2024Final—progress
12/01/2023FinalJeffery Poveroprogress
Latest 25 of 26.
▾Documents — 52 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/28/2026M00966498-P1Request digital key ↗
08/28/2026M00966498-I1Request digital key ↗
08/27/2026M00996727-S2Request digital key ↗
Showing 3 of 8 on file for this type
▸Applications & Permits7
▸DOB NOWLPC Approval/Permit7
08/28/2026M00966498-I1Open ↗
08/27/2026M00996727-S2Open ↗
08/27/2026M00996727-S4Open ↗
Showing 3 of 7 on file for this type
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026M00996727-I1Open ↗
▸Seals & Professional Certifications9
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/28/2026M00966498-I1Open ↗
08/27/2026M01010530-I1Open ↗
08/13/2026M00966498-P1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWProgress Inspector Seal & Signature1
08/31/2026M00966498-I1Open ↗
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/13/2026M00996727-S4Open ↗
08/13/2026M00996727-I1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist2
08/13/2026M00996727-I1Open ↗
08/13/2026M00996727-S4Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/15/2026M01010530-I1Open ↗
08/13/2026M00996727-S4Open ↗
08/13/2026M00996727-S2Open ↗
Showing 3 of 6 on file for this type
▸Inspections & Test Reports1
▸DOB NOWSOIL REPORT1
08/13/2026M00996727-S5Open ↗
▸Approvals, Objections & Sign-offs6
▸DOB NOWLandmark Approval4
08/13/2026M00996727-S5Open ↗
08/13/2026M00996727-S1Open ↗
08/13/2026M00996727-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDEP Variance (V5) letter2
08/13/2026M00996727-S1Open ↗
08/13/2026M00996727-S2Open ↗
▸Other Documents10
▸DOB NOWPlot Diagram3
08/13/2026M00996727-S4Open ↗
08/13/2026M00996727-S5Open ↗
08/13/2026M00996727-I1Open ↗
▸DOB NOWSite Survey: Initial2
08/13/2026M00996727-I1Open ↗
08/13/2026M00996727-S4Open ↗
▸DOB NOWProof of Historic Building2
08/28/2026M00966498-I1Open ↗
08/13/2026M00966498-P1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026M00996727-I1Open ↗
08/13/2026M00996727-S4Open ↗
▸DOB NOWProperty Ownership Certification1
08/13/2026M00996727-I1Open ↗