HPD06/25/2026§ 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A FIREPROOF PASSAGEWAY FROM FIRE ESCAPES AT REAR TO STREET AND FILE APPLICATION FOR APPROVAL BEFORE DOING THIS WORK. YARD
HPD06/25/2026§ 27-2005 HMC: IMMEDIATELY PROVIDE A FIRE GUARD AS DIRECTED BY THE NYC DEPT. OF HOUSING PRESERVATION & DEVELOPMENT (HPD) AND/OR THE NYC DEPT. OF BUILDINGS (DOB) TO PROTECT AGAINST FIRE HAZARDS OBSERVED BY HPD AND/OR DOB. FIRE HAZARDS OBSERVED BY HPD HAVE RESULTED IN THE FOLLOWING ADDITIONAL HPD VIOLATION(S): VIOLATION # 19040681 IN ORDER TO PROTECT PUBLIC SAFETY AGAINST IMMINENT FIRE HAZARDS OBSERVED, A FIRE GUARD MUST BE PROVIDED FORTHWITH FOR CONTINUOUS 24 HOUR COVERAGE, NOTWITHSTANDING THE CORRECTION AND CERTIFICATION DATES SET FORTH ABOVE (THE CORRECTION AND CERTIFICATION DATES SET FORTH ABOVE ARE APPLICABLE FOR PURPOSES OF CIVIL PENALTIES THAT MAY BE ASSESSED PURSUANT TO NYC ADMINISTRATIVE CODE § 27-2115, BUT DO NOT REFLECT THE DATE BY WHICH A FIRE GUARD MUST BE PROVIDED). A FIRE GUARD MUST BE PROVIDED IMMEDIATELY DUE TO THE EXIGENCY OF THE DANGEROUS FIRE HAZARD CONDITIONS OBSERVED. THE VIOLATION REQUIRING A FIRE GUARD TO BE PROVIDED WILL REMAIN OPEN UNTIL SUCH TIME AS THE FIRE HAZARDS RESULTING IN THE HPD VIOLATION(S) REFERENCED ABOVE AND/OR THE FIRE HAZARDS RESULTING IN RELATED DOB VIOLATION(S) HAVE BEEN DISMISSED.
ECB10/08/2025FAILURE TO COMPLY AND SUBMIT CERTIFICATE OF CORRECTIONS FOR VIOLATION # 39109999R ISSUED ON 03/27/2024 FOR FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER., FILE A CERTIFICATE OF CORRECTION$6K due
HPD03/23/2025§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED TO BOILER ROOM , 1st STORY
HPD03/23/2025§ 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST
ECB03/06/2025FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS #39109700N ISSUED ON 03/25/2024, AND FAILURE TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28.201.1 AND 1 RCNY 102-01(D)(2). AN ACCEPTABLE CERT$6K due
DOB05/29/2024FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB03/27/2024BC 3307.6.4.8 AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED INSTALLED ON EXPOSURE #1 WITH INOPERABLE LIGHT BULBS AT UNDERSIDE THE SHED TO BRING ILLUMINATION FAILURE TO PROVIDE LIGHTING CREATES UNSAFE AND MUGG$10K due
ECB03/27/2024FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: 6 STORY BLDG STAIRCASE THROUGHOUT BLDG IS IN A STATE OF DISREPAIR. STAIRCASES ARE NOT LEVELED, SLOPING TO ONE SIDE AND CREAKING. BTWN THE 4TH/5TH FL$6K due
ECB03/25/2024AT TIME OF INSPECTION OBSERVED EXTERIOR FACADE ON EXPOSURE # 02 INSTATE OF DISREPAIR CONDITION WITH PARAPET STUCCO CRACKS, SPALLING, LOOSE AND SECTION MISSING ON ROOF LEVEL., MAINTAIN EXTERIOR BUILDING WALL$630 due
HPD02/29/2024§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR AND FRAME BOILER ROOM AT BASEMENT
DOB11/09/2023AT TIME OF INSPECTION OBSERVED VERTICAL & STEP CRACKS ON FRONT FACADE 1ST & 2ND FLOOR LEVEL. ALSO OBSERVED CRACK METERS IN PLACE. UNABLE TO DETERMINE THE CAUSE OF CRACKS.
HPD10/22/2023§ 27-2005 HMC: REFIT DOOR LEADING TO BOILER ROOM AT BASEMENT
HPD10/22/2023§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR AND FRAME LEADING TO BOILER ROOM AT BASEMENT
HPD12/16/2022§ 27-2049 ADM CODE POST AND MAINTAIN A STREET NUMBER ON THE FRONT OF THE DWELLING PLAINLY VISIBLE FROM THE SIDEWALK.
HPD04/06/2022§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES AT PUBLIC HALL, 1st STORY
HPD12/29/2020§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM ... AT PUBLIC HALL, 1st STORY
HPD10/24/2020§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY
HPD10/24/2020§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY
ECB07/19/2023FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED AT EXP #4, STUCCO OVER BRICK IS IN STATE OF DISREPAIR WITH SECTIONS OF STUCCO LOOSE AND OR MISSING AT MULTIPLE LOCATIONS., RNothing owed — awaiting certificate of correction