← Back
Converted dwellings or rooming house
130 WEST 82 STREET
MANHATTAN · BIN 1032031
💬 Discuss this project
1887Year Built
4Stories
C5Building Class
R8BZoning
6,305 sfGross Floor Area
10Units
Rent Stabilized1 Open Violation ▸
Converted dwellings or rooming house · Owner of record: SILVERTON ASSOCIATES L.L.C. · 2,043 sf lot · 3.09 FAR built · Flood zone X
Locations of Work
ArchitectureGeneralOther
Roof2p · 1 filing · 6 docs
Floor 31p · 1 filing · 6 docs
Floor 2
Floor 1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
KINGS GROUP NY907/08/2026
SACKMAN ENTERPRISES807/08/2026
SILVERTON ASSOCIATES L.L.C.103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
RIMKUS210/28/2024
FEINGOLD AND GREGORY ARCH.212/14/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KMA DESIGNS LLC403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KINGS GROUP NY CORPGeneral Contractor407/08/2026
BES MECHANICAL LLCPlumbing207/08/2026
N.Y. EMS MECHANICAL CORPPlumbing207/08/2026
ALEXANDER EUGENEElectrical103/21/2026
HIGH QUALITY ELECTRIC OFElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
FEINGOLD & GREGORY ARCHIT979112/14/2020
Building Lifecycle
All (37)Filed (4)Permit Issued (6)Signed Off (2)Violation (20)Inspection (3)Special Inspection (2)
03/04/2025
Signed off — Alteration
installation of pipe scaffolding. no change in use, occupancy or egress. work shall comply with chapter 33 of nycc.
M01133168-I1
03/04/2025
Signed off — Alteration
installation of pipe scaffolding. no change in use, occupancy or egress. work shall comply with chapter 33 of nycc.
M01133168-S1
10/29/2024
Permit issued — Sidewalk Shed
M01133168-I1-SH
10/28/2024
Filed — Alteration
installation of pipe scaffolding. no change in use, occupancy or egress. work shall comply with chapter 33 of nycc.
M01133168-I1
10/28/2024
Filed — Alteration
installation of pipe scaffolding. no change in use, occupancy or egress. work shall comply with chapter 33 of nycc.
M01133168-S1
10/28/2024
Permit issued — Supported Scaffold
M01133168-S1-SF
04/02/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/01/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/29/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/20/2024
Permit issued — Plumbing
M00437340-I1-PL
01/31/2023
Permit issued — Plumbing
M00437340-I1-PL
04/21/2022
Permit issued — Plumbing
M00437340-I1-PL
06/30/2021
Permit issued — Plumbing
M00437340-I1-PL
04/01/2021
Violation issued (HPD, closed)
A
12/14/2020
Filed — Alteration
INSTALL NEW EXHAUST FOR RELOCATED K'TTE ON 3RD FLOOR REAR APARTMENT AND RECONFIGURED BATH ON 4TH FLOOR REAR APARTMENT.
M00438507-I1
12/14/2020
Filed — Alteration
Plumbing required to complete apartment combination for 3R AND 4R. Remove ktte and bathtub, relocate washbasin and toilet, and install new shower on 4. Relocate k'tte on 3 - Sink, dishwasher and stove.
M00437340-I1
12/09/2020
Special inspection requirement — Mechanical Systems
Paul Gregory
12/09/2020
Special inspection requirement — Final
Paul Gregory
11/08/2019
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/23/2008
Violation issued (ECB, closed)
Construction
11/28/2007
Violation issued (ECB, closed)
Construction
01/19/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/06/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/31/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/31/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/07/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/16/1999
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/04/1998
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/18/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/18/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/04/1988
Violation issued (HPD, closed)
A
10/04/1988
Violation issued (HPD, closed)
A
10/04/1988
Violation issued (HPD, closed)
B
10/04/1988
Violation issued (HPD, closed)
B
10/04/1988
Violation issued (HPD, closed)
C
10/04/1988
Violation issued (HPD, closed)
A
10/04/1988
Violation issued (HPD, closed)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSidewalk ShedSigned-offKINGS GROUP NY CORP10/29/2024
DOB NOWSupported ScaffoldSigned-offKINGS GROUP NY CORP10/28/2024
DOB NOWPlumbingSigned-offL AND I MECH. CONTRS. INC03/20/2024
DOB NOWPlumbingSigned-offL AND I MECH. CONTRS. INC01/31/2023
DOB NOWPlumbingSigned-offN.Y. EMS MECHANICAL CORP04/21/2022
DOB NOWPlumbingSigned-offN.Y. EMS MECHANICAL CORP06/30/2021
BISOTISSUEDBERKLEY GENERAL CONTRACTO10/29/2021
BIS—ISSUEDSACKMAN ENTERP5IESE INC11/08/2007
BISPLISSUEDHASSEL PLG CORP08/03/2007
BIS—ISSUEDSACKMAN ENTERP5IESE INC10/19/2006
BISPLISSUEDHASSEL PLG CORP01/11/2000
BISPLISSUEDHASSEL PLG CORP01/11/2000
BISOTISSUEDSACKMAN ENTERPRISES INC12/27/1999
BIS—ISSUEDSACKMAN ENTERP5IESE INC10/07/1999
1 project · most recent 12/14/2020
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
12/14/2020——Ventilation Systems
Ventilation
__Junk__ NONE 150 CFM · Exhaust Fan ×2
KTICHE FAN 150 CFM · Exhaust Fan ×1
vent fan 50 CFM ×1
1 project · most recent 12/14/2020
Water/Sanitary
FiledStatusContractorScope
12/14/2020Signed-offL AND I MECH. CONTRS. INCWater/Sanitary
1 project · most recent 10/29/2024
FiledStatusContractorScope
10/29/2024CompleteHIGH QUALITY ELECTRIC OF—
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
04/02/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
04/01/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/29/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
12/09/2020Mechanical SystemsPaul Gregoryspecial
12/09/2020FinalPaul Gregoryprogress
▾Documents — 36 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch2
08/25/2026M01133168-S1Request digital key ↗
08/25/2026M01133168-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems1
09/04/2026M00438507-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing1
09/04/2026M00437340-I1Request digital key ↗
▸Applications & Permits5
▸BISPLAN / WORK APPROVAL APPLICATION2
12/07/2020140984558Open ↗
12/03/2019102215014Open ↗
▸DOB NOWLPC Approval/Permit2
08/13/2026M00438507-I1Open ↗
08/13/2026M00437340-I1Open ↗
▸BISWORK PERMIT APPLICATION1
05/06/2021140984558Open ↗
▸Seals & Professional Certifications8
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/25/2026M01133168-I1Open ↗
08/25/2026M01133168-S1Open ↗
08/13/2026M00438507-I1Open ↗
Showing 3 of 4 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
12/07/2020140984558Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
12/07/2020140984558Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
12/07/2020140984558Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/28/2026M00438507-I1Open ↗
▸Safety & Tenant Protection3
▸DOB NOWTenant Protection Plan2
08/13/2026M00437340-I1Open ↗
08/13/2026M00438507-I1Open ↗
▸BISTPP1: TENANT PROTECTION PLAN1
05/03/2021140984558Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS: COMPLETION OR CLOSEOUT (ACP20/21/5)1
05/03/2021140984558Open ↗
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form1
08/13/2026M00437340-I1Open ↗
▸Energy Compliance7
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
12/07/2020140984558Open ↗
▸BISINSULATION PLACEMENT & R VALUES1
05/03/2021140984558Open ↗
▸BISINTERIOR LIGHTING POWER1
05/03/2021140984558Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
12/07/2020140984558Open ↗
▸BISNYCECC ANALYSIS1
12/07/2020140984558Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
05/03/2021140984558Open ↗
▸BISLIGHTING CONTROLS1
05/03/2021140984558Open ↗
▸Inspections & Test Reports3
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
05/03/2021140984558Open ↗
▸BISDIR-14 ID OF RESPONSIBILITY (TR1)1
05/03/2021140984558Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY1
12/07/2020140984558Open ↗
▸Approvals, Objections & Sign-offs2
▸BISFINAL1
05/03/2021140984558Open ↗
▸BISLANDMARKS APPROVAL1
12/07/2020140984558Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
12/07/2020140984558Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
12/07/2020140984558Open ↗