← Back
Walk-up cooperative
334 EAST 77 STREET
MANHATTAN · BIN 1045181
💬 Discuss this project
1910Year Built
5Stories
C6Building Class
R8BZoning
10,060 sfGross Floor Area
19Units
Rent Stabilized6 Open Violations ▸
Walk-up cooperative · Owner of record: 332-336 EAST 77TH STREET ASSOC · 2,554 sf lot · 3.94 FAR built · Flood zone X
Locations of Work
MechanicalOther
Roof1p · 1 filing · 9 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
332-336 EAST 77TH STREET ASSOC103/22/2026
332 336 EAST 77 ST ASS103/22/2026
332-336 E 77TH ST ASSOCIATES603/21/2026
KENILWORTH EQUITIES203/21/2026
PHOENIX BRIDGING INC DBA PHOENIX403/21/2026
332-336 E 77 ST OWNERS203/21/2026
333-336 E 7TH ST ASSOC203/21/2026
C/O KENILWORTH EQUITIES203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PE AND CONSULTANTS NY LLC105/11/2026
AB ARCHITEKTEN205/07/2026
TAREK M. ZEID, PE, PLLC102/06/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
M W EXPEDITING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
EMIL KRSLOVICElectrical103/21/2026
Building Lifecycle
All (58)Filed (4)Violation (17)Objection (24)Special Inspection (13)
08/12/2026
Objection resolved — Resolved
08/12/2026
Objection resolved — Resolved
08/12/2026
Objection resolved — Resolved
08/12/2026
Objection resolved — Resolved
08/12/2026
Objection resolved — Resolved
08/12/2026
Special inspection requirement — Structural Wood Frame
08/12/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
07/23/2026
Special inspection requirement — HVAC-R and service water heating system controls
07/23/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
07/23/2026
Special inspection requirement — HVAC-R and service water heating equipment
07/21/2026
Objection resolved — Resolved
06/12/2026
Objection resolved — Resolved
06/12/2026
Objection resolved — Resolved
06/12/2026
Objection resolved — Resolved
06/12/2026
Objection resolved — Resolved
06/12/2026
Objection resolved — Resolved
06/12/2026
Objection resolved — Resolved
06/07/2026
Objection raised — Cost
06/07/2026
Objection raised — Inspections
06/07/2026
Objection raised — Admin
06/07/2026
Objection raised — Inspections
06/07/2026
Objection raised — Admin
05/28/2026
Objection raised — Scope
05/28/2026
Objection raised — Cost
05/28/2026
Objection raised — Inspections
05/28/2026
Objection raised — Admin
05/28/2026
Objection raised — Scope
05/26/2026
Objection raised — Cost
05/26/2026
Objection raised — Admin
05/11/2026
Filed — Alteration
REINFORCE ROOF JOISTS BY SISTERING NEW JOISTS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01384935-S2
05/07/2026
Filed — Alteration
REINFORCE ROOF JOISTS BY SISTERING NEW JOISTS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01384935-S1
05/07/2026
Filed — Alteration
REINFORCE ROOF JOISTS BY SISTERING NEW JOISTS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01384935-I1
05/01/2026
Special inspection requirement — Tenant Protection Plan Compliance
05/01/2026
Special inspection requirement — Wood – Prefabricated I-Joists
05/01/2026
Special inspection requirement — Wood – Seismic Resistance
05/01/2026
Special inspection requirement — Designated Seismic System
04/29/2026
Violation issued (HPD, closed)
A
04/16/2026
Special inspection requirement — Tenant Protection Plan Compliance
04/09/2026
Special inspection requirement — Final
04/09/2026
Special inspection requirement — Mechanical Systems
04/09/2026
Special inspection requirement — Final
11/17/2025
Violation issued (HPD, closed)
I
04/01/2024
Violation issued (HPD, closed)
A
12/23/2022
Violation issued (HPD, open)
C
12/23/2022
Violation issued (HPD, open)
C
02/15/2022
Violation issued (HPD, closed)
I
02/15/2022
Violation issued (HPD, closed)
A
02/06/2020
Filed — Alteration
M00285429-I1
10/09/2018
Violation issued (HPD, closed)
I
10/01/2015
Violation issued (HPD, closed)
I
07/25/2000
Violation issued (HPD, open)
B
07/25/2000
Violation issued (HPD, closed)
B
04/11/1996
Violation issued (ECB, closed)
Construction
03/19/1996
Violation issued (DOB, open)
VP-VIOLATION UNSERVED ECB-ACTIVE
03/18/1994
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/18/1993
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
12/17/1991
Violation issued (HPD, closed)
B
04/20/1989
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISOTISSUEDPREMIER RESTORATION &04/14/2021
BISOTISSUEDG.GRECH CONSTRUCTION & P07/31/2020
BISOTISSUEDG. GRECH CONSTRUCTION & P07/22/2019
BISOTISSUEDG. GRECH CONSTRUCTION & P07/15/2019
BISEQISSUEDPHOENIX SUTTON STR INC02/26/2013
BISEQISSUEDPHOENIX SUTTON STR INC02/22/2013
BISBLISSUEDABILENE, INC04/02/2009
BISPLISSUEDVANGUARD PLUMBING02/21/1992
BISPLISSUEDASSOCIATED MECHANICAL CO02/19/1992
BISOTISSUEDBULDING WORK01/30/1992
BISOTISSUEDJ AND J AUDIFFRED CONTRACTING CO01/27/1992
1 project · most recent 05/11/2026
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
05/11/2026——Air Conditioning Systems
Cooling
Mitsubishi Electric MSZ - GX9NL 12,200 BTU · Ahu ×1
MSZ-GX12NL 14,000 BTU · Ahu ×1
MXZ-2D2ONL 20,000 BTU · Condensing Unit ×1
1 project · most recent 02/27/2026
General Wiring
FiledStatusContractorScope
02/27/2026CompleteLINA ELECTRIC, CORPGeneral Wiring
1 project · most recent 05/11/2026
Wood
FiledStatusContractorScope
05/11/2026——Wood
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
08/12/2026Structural Wood Frame—progress
08/12/2026Structural Stability – Alterations of existing buildings—special
07/23/2026HVAC-R and service water heating system controls—energy_progress
07/23/2026HVAC-R and service water piping design and insulation—energy_progress
07/23/2026HVAC-R and service water heating equipment—energy_progress
05/01/2026Tenant Protection Plan Compliance—special
05/01/2026Wood – Prefabricated I-Joists—special
05/01/2026Wood – Seismic Resistance—special
05/01/2026Designated Seismic System—special
04/16/2026Tenant Protection Plan Compliance—special
04/09/2026Final—progress
04/09/2026Mechanical Systems—special
04/09/2026Final—progress
▾Documents — 89 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch3
08/15/2026M01384935-S2Request digital key ↗
08/15/2026M01384935-I1Request digital key ↗
08/14/2026M01384935-S1Request digital key ↗
▸DOB NOWPlans/Sketch - Structural1
09/05/2026M00285429-I1Request digital key ↗
▸Applications & Permits18
▸BISPLAN / WORK APPROVAL APPLICATION10
01/27/2021123207369Open ↗
12/22/2020123207369Open ↗
11/05/2020123570304Open ↗
Showing 3 of 10 on file for this type
▸BISWORK PERMIT APPLICATION8
04/14/2021123570304Open ↗
12/13/2019123207369Open ↗
07/22/2019123207369Open ↗
Showing 3 of 8 on file for this type
▸Seals & Professional Certifications21
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION11
02/28/2020123570304Open ↗
07/22/2019123207369Open ↗
07/22/2019123207369Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
09/05/2026M00285429-I1Open ↗
08/17/2026M01384935-I1Open ↗
08/17/2026M01384935-S2Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST3
08/01/2018123529636Open ↗
03/04/2013121545774Open ↗
02/26/2013121540742Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM2
03/04/2013121545774Open ↗
02/26/2013121540742Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
08/01/2018123529636Open ↗
▸Trade Schedules & Equipment4
▸BISSCHEDULE B - PLUMBING2
01/27/2021123207369Open ↗
12/22/2020123207369Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
02/15/2018123207369Open ↗
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
03/12/2009110471338Open ↗
▸Safety & Tenant Protection4
▸BISTENANT PROTECTION PLAN AND NOTES3
02/18/2021123207369Open ↗
12/10/2020123570304Open ↗
08/01/2018123529636Open ↗
▸DOB NOWTenant Protection Plan1
08/13/2026M00285429-I1Open ↗
▸Environmental & Asbestos9
▸BISASBESTOS: CERTIFICATION (DEP ACP5)4
05/28/2020123570304Open ↗
08/01/2018123529636Open ↗
02/15/2018123207369Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
09/05/2026M00285429-I1Open ↗
08/15/2026M01384935-S2Open ↗
08/15/2026M01384935-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
03/12/2009110471338Open ↗
▸Energy Compliance6
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS4
02/28/2020123570304Open ↗
07/22/2019123207369Open ↗
08/01/2018123529636Open ↗
Showing 3 of 4 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS1
03/19/2021123207369Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
03/19/2021123207369Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
03/22/2021123207369Open ↗
03/22/2021123207369Open ↗
▸Approvals, Objections & Sign-offs9
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST4
03/22/2021123207369Open ↗
02/10/2014121540742Open ↗
09/20/2013121545774Open ↗
Showing 3 of 4 on file for this type
▸BISADMINISTRATIVE OBJECTIONS3
03/04/2013121545774Open ↗
02/26/2013121540742Open ↗
03/12/2009110471338Open ↗
▸BISSHED LETTER1
02/10/2014121540742Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
09/20/2013121545774Open ↗
▸Cost, Insurance & Ownership5
▸BISCOST AFFIDAVIT5
03/19/2021123207369Open ↗
02/28/2020123570304Open ↗
08/01/2018123529636Open ↗
Showing 3 of 5 on file for this type
▸Filing & Intake Forms7
▸BISEFILING COVER SHEET5
02/28/2020123570304Open ↗
08/01/2018123529636Open ↗
02/15/2018123207369Open ↗
Showing 3 of 5 on file for this type
▸BISADDITIONAL INFORMATION2
09/16/2020123207369Open ↗
07/22/2020123207369Open ↗