← Back
Walk-up apt, over six families with stores
115 EAST 96 STREET
MANHATTAN · BIN 1051696
💬 Discuss this project
1920Year Built
6Stories
C7Building Class
R10AZoning
14,658 sfGross Floor Area
25Units
Rent Stabilized0 Open ViolationsFISP: SWARMP
Walk-up apt, over six families with stores · Owner of record: 115 E 96 ST CORP · 3,784 sf lot · 3.87 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
RELIABLE ENTERPRISES807/08/2026
115 E 96 ST CORP103/22/2026
115 EAST 96TH ST.CORP103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ENTHINK ENGINEERS LLC204/28/2023
WAYPOINT CONSULTING GROUP104/26/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PADMA CONTRACTING CORPGeneral Contractor407/08/2026
RELIABLE ENTERPRISES INCGeneral Contractor407/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CHANDA ENG. CONSULTANT PC6842104/26/2023
Building Lifecycle
All (25)Filed (3)Permit Issued (4)Signed Off (3)Facade (FISP) (12)Violation (3)
01/22/2024
Signed off — Alteration
M00852176-I1
11/15/2023
Violation issued (HPD, closed)
I
10/04/2023
Signed off — Alteration
PROPOSED INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. WORK SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
M00866184-I1
10/04/2023
Signed off — Alteration
M00866167-I1
09/19/2023
Permit issued — General Construction
M00852176-I1-GC
05/08/2023
Permit issued — General Construction
M00852176-I1-GC
04/28/2023
Filed — Alteration
PROPOSED INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. WORK SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
M00866184-I1
04/28/2023
Filed — Alteration
M00866167-I1
04/28/2023
Permit issued — Supported Scaffold
M00866184-I1-SF
04/28/2023
Permit issued — Sidewalk Shed
M00866167-I1-SH
04/26/2023
Filed — Alteration
M00852176-I1
09/16/2022
Cycle 9 facade report signed — SWARMP
02/18/2022
Cycle 9 facade report submitted
01/25/2022
Cycle 9 facade inspection completed
02/17/2017
Cycle 8 facade report submitted
02/14/2017
Cycle 8 facade report signed — SAFE
02/05/2017
Cycle 8 facade inspection completed
08/19/2016
Violation issued (ECB, closed)
Construction
01/31/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/24/2012
Cycle 7 facade report submitted
10/22/2012
Cycle 7 facade report signed — SAFE
09/16/2012
Cycle 7 facade inspection completed
02/16/2007
Cycle 6 facade report submitted
02/12/2007
Cycle 6 facade report signed — SAFE
02/07/2007
Cycle 6 facade inspection completed
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offPADMA CONTRACTING CORP09/19/2023
DOB NOWGeneral ConstructionSigned-offPADMA CONTRACTING CORP05/08/2023
DOB NOWSupported ScaffoldSigned-offRELIABLE ENTERPRISES INC04/28/2023
DOB NOWSidewalk ShedSigned-offRELIABLE ENTERPRISES INC04/28/2023
BISEQISSUEDPRINCE CONTRACTING INC07/28/2000
BISBLISSUEDHERCULES WELDING & BOILER05/07/1999
1 project · most recent 05/05/2023
FiledStatusContractorScope
05/05/2023CompleteRICHARD NEU—
Nothing on file for this building.
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/31/2026M00852176-I1Request digital key ↗
08/31/2026M00866167-I1Request digital key ↗
08/31/2026M00866184-I1Request digital key ↗
▸Seals & Professional Certifications3
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/31/2026M00852176-I1Open ↗
08/31/2026M00866167-I1Open ↗
08/13/2026M00866184-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/31/2026M00852176-I1Open ↗