← Back
Parsonage, rectory
444 EAST 119 STREET
MANHATTAN · BIN 1054831
💬 Discuss this project
1910Year Built
4Stories
M3Building Class
R7BZoning
6,500 sfGross Floor Area
1Units
2 Open Violations ▸
Parsonage, rectory · 2,523 sf lot · 2.58 FAR built · Flood zone X500
Locations of Work
ArchitectureMechanicalPlumbingCivilGeneral
Roof10p · 2 filings · 17 docs
Floor 101p · 1 filing · 13 docs
Floor 9
Floor 8
Floor 7
Floor 6
Floor 5
Floor 48p · 2 filings · 17 docs
Floor 37p · 2 filings · 17 docs
Floor 26p · 2 filings · 17 docs
Floor 17p · 2 filings · 17 docs
Cellar6p · 1 filing · 13 docs
Basement2p · 1 filing · 4 docs
1 job · most recent 07/01/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
07/01/2026——Heating and Air Conditioning Systems
Heat / Cool
Daikin 3MXM24AVJU9 24,000 BTU · Heat Pump Outdoor ×6
RXF18AXVJU 21,600 BTU · Heat Pump Outdoor ×4
RXF12AXVJU 13,500 BTU · Heat Pump Outdoor ×3
4MXM36AVJU9 34,600 BTU · Heat Pump Outdoor ×2
1 job · most recent 07/01/2026
Sprinkler System
FiledStatusContractorScope
07/01/2026——Sprinkler System
1 job · most recent 07/01/2026
Storm Water/Sanitary
FiledStatusContractorScope
07/01/2026——Storm, Water/Sanitary
1 job · most recent 12/16/2025
General Wiring
FiledStatusContractorScope
12/16/2025Permit IssuedS&R ELECTRICAL & MECHANICGeneral Wiring
Building Lifecycle
All (53)Filed (5)Violation (14)Objection (10)Special Inspection (24)
09/25/2026
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
08/10/2026
Objection resolved — Resolved
08/10/2026
Objection resolved — Resolved
08/03/2026
Objection raised — Scope
08/03/2026
Objection raised — Structural
08/03/2026
Objection resolved — Open
07/30/2026
Objection resolved — Resolved
07/27/2026
Objection raised — Other
07/14/2026
Objection raised — Other
07/01/2026
Filed — Alteration CO
PROPOSED INTERIOR RENOVATION CONVERTING EXISTING 4 STORY AND CELLAR, INTO A 15 UNIT RESIDENTIAL BUILDING.
M01256895-S3
07/01/2026
Special inspection requirement — Post-installed Anchors
07/01/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/30/2026
Special inspection requirement — Sprinkler Systems
06/22/2026
Filed — Alteration CO
PROPOSED INTERIOR RENOVATION CONVERTING EXISTING 4 STORY AND CELLAR, INTO A 15 UNIT RESIDENTIAL BUILDING.
M01256895-S2
06/22/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/22/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
06/22/2026
Special inspection requirement — Maintenance information
06/22/2026
Special inspection requirement — HVAC-R and service water heating system controls
06/22/2026
Special inspection requirement — HVAC-R and service water heating equipment
06/08/2026
Special inspection requirement — Protection of exposed foundation insulation
06/03/2026
Filed — Alteration CO
PROPOSED INTERIOR RENOVATION CONVERTING EXISTING 4 STORY AND CELLAR, INTO A 15 UNIT RESIDENTIAL BUILDING.
M01256895-S1
05/27/2026
Special inspection requirement — Lighting in dwelling units
05/13/2026
Special inspection requirement — Air barrier - visual inspection
05/13/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
05/13/2026
Special inspection requirement — Permanent certificate
09/04/2025
Objection raised — Other
08/28/2025
Special inspection requirement — Insulation placement and R values
08/28/2025
Special inspection requirement — Maintenance information
08/08/2025
Filed — Alteration CO
PROPOSED INTERIOR RENOVATION CONVERTING EXISTING 4 STORY AND CELLAR, INTO A 15 UNIT RESIDENTIAL BUILDING.
M01256895-I1
07/25/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
07/25/2025
Special inspection requirement — Fenestration air leakage
07/25/2025
Special inspection requirement — Metering
07/25/2025
Special inspection requirement — Energy Code Compliance Inspections
07/25/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
07/25/2025
Special inspection requirement — Fenestration areas
07/25/2025
Special inspection requirement — Fire-Resistance Rated Construction
10/24/2024
Objection raised — Admin
10/07/2024
Filed — Full Demolition
Demolition of a multi-storey building
M01104767-I1
09/20/2024
Special inspection requirement — Structural Stability – Alterations of existing Buildings
09/16/2024
Special inspection requirement — Demolition
04/05/2019
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/15/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/01/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/01/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/10/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/31/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/31/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/04/2013
Violation issued (ECB, closed)
Boilers
12/13/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/12/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/16/2010
Violation issued (ECB, closed)
Cranes and Derricks
02/10/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/03/1989
Violation issued (ECB, closed)
Boilers
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
AFS SYSTEMS308/28/2026
RC CHURCH HOLY ROSARY C/O CS303/22/2026
RC CHURCH HOLY ROSARY C O CS203/21/2026
GOLANI DEVELOPMENT GROUP103/21/2026
HOLY ROSARY CHURCH103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
VASILIOS ARTEMIOU PE307/01/2026
NIKOLAI KATZ ARCHITECT108/08/2025
LMW ENGINEERING GROUP LLC110/07/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EXPRESS FILING INC203/21/2026
POP TOP OF NY INC.103/21/2026
POP TOP103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MITACEK, JOHNElectrical103/21/2026
VAN VASSELLElectrical103/21/2026
YOSEF BLAUElectrical103/21/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISEQISSUEDCS BRIDGE CORP09/06/2011
BISEQISSUEDCS BRIDGE CORP09/02/2011
BISOTISSUEDA & S WATERPROOFING & RES03/11/2011
BISOTISSUEDTEWKSBURY CONSTRUCTION CO.07/08/1999
BISFBISSUEDMARLANDE HTG CORP05/12/1999
▾Special Inspection Requirements (DOB NOW) — 24
DateRequirementInspectorRole
07/01/2026Post-installed Anchors—special
07/01/2026Fire-Resistant Penetrations and Joints—special
06/30/2026Sprinkler Systems—special
06/22/2026Fire-Resistant Penetrations and Joints—special
06/22/2026HVAC-R and service water piping design and insulation—energy_progress
06/22/2026Maintenance information—energy_progress
06/22/2026HVAC-R and service water heating system controls—energy_progress
06/22/2026HVAC-R and service water heating equipment—energy_progress
06/08/2026Protection of exposed foundation insulation—energy_progress
05/27/2026Lighting in dwelling units—energy_progress
05/13/2026Air barrier - visual inspection—energy_progress
05/13/2026Structural Stability – Alterations of existing buildings—special
05/13/2026Permanent certificate—energy_progress
08/28/2025Insulation placement and R values—energy_progress
08/28/2025Maintenance information—energy_progress
07/25/2025Fenestration and door U-factor and product ratings—energy_progress
07/25/2025Fenestration air leakage—energy_progress
07/25/2025Metering—energy_progress
07/25/2025Energy Code Compliance Inspections—progress
07/25/2025Fire-Resistant Penetrations and Joints—special
07/25/2025Fenestration areas—energy_progress
07/25/2025Fire-Resistance Rated Construction—progress
09/20/2024Structural Stability – Alterations of existing Buildings—special
09/16/2024Demolition—special
▾Documents — 47 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/22/2026M01256895-S1Request digital key ↗
08/17/2026M01256895-I1Request digital key ↗
08/15/2026M01256895-S1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits7
▸BISPLAN / WORK APPROVAL APPLICATION4
09/19/2011120814752Open ↗
09/16/2011120694490Open ↗
03/15/2011120622601Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION3
09/20/2011120814752Open ↗
09/16/2011120694490Open ↗
03/15/2011120622601Open ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZoning Exhibit form (1-5)1
08/17/2026M01256895-I1Open ↗
▸Seals & Professional Certifications14
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/17/2026M01256895-S1Open ↗
08/17/2026M01256895-S2Open ↗
08/17/2026M01256895-S3Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
10/17/2011120694490Open ↗
05/20/2011120622601Open ↗
03/11/2011120622601Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM3
09/19/2011120814752Open ↗
09/16/2011120694490Open ↗
03/11/2011120622601Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
10/07/2011120814752Open ↗
03/11/2011120622601Open ↗
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist2
08/17/2026M01256895-I1Open ↗
08/13/2026M01256895-I1Open ↗
▸Environmental & Asbestos5
▸BISTHIS IS NOT AN ASBESTOS PROJECT2
09/19/2011120814752Open ↗
09/19/2011120814752Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
09/16/2011120694490Open ↗
▸BISASBESTOS-CERTIFICATION (DEP ACP5)1
03/17/2011120622601Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026M01104767-I1Open ↗
▸Approvals, Objections & Sign-offs3
▸BISADMINISTRATIVE OBJECTIONS2
10/17/2011120814752Open ↗
03/11/2011120622601Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
05/20/2011120622601Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
05/20/2011120622601Open ↗
03/17/2011120622601Open ↗
▸Filing & Intake Forms4
▸BISEFILING COVER SHEET3
09/19/2011120814752Open ↗
09/16/2011120694490Open ↗
03/11/2011120622601Open ↗
▸BISeFiling Job Application Cover Sheet1
03/15/2011120622601Open ↗
▸Other Documents3
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
05/20/2011120622601Open ↗
▸DOB NOWProperty Ownership Certification1
08/13/2026M01256895-I1Open ↗
▸DOB NOWStructure Photographs1
08/13/2026M01104767-I1Open ↗