ECB08/05/2026ATOI, OBSERVED THAT GARAGE SPACE WAS BEING OCCUPIED CONTRARY TO VACATE ISSUED ON 12/30/2024., COMPLY WITH VACATE ORDER$10K due
ECB08/05/2026ATOI, OBSERVED THAT PARKING GARAGE BEING UTILIZED AS STORAGE FACILITY FOR THEATRE EQUIPMENT CONTRARY TO DOB RECORDS., DISCONTINUE ILLEGAL OCCUPANCY OR AMEND C OF O$2K due
ECB07/30/2026AT TIME OF INSPECTION 4:30 AM, OBSERVED DEFECTIVE LIGHTING AT SIDEWALK SHED EXPS.1 CREATING DARK CONDITION. HAZARDOUS TO TENANTS/PEDESTRIANS, RISK OF SLIP/TRIP/FALL AND CRIMINAL ACTIVITY. NO PREVENTIVE MEASURES$2K due
ECB07/15/2026ATOI, OBSERVED THAT VACATE STICKER HAS BEEN REMOVED., COMPLY WITH CODE; DO NOT REMOVE VACATE STICKER.$5K due
ECB06/27/2025FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER, NOTE AT EXP #1 MISSING BRICKS UNDER LINTEL OBSERVED CRACKED DETORIATED STONE MULTIPLELOCATIONS. AT EXP #4 OBSERVED OPEN PART OF CORNICE OBSERVED OPEN MORTA$12K due
DOB03/05/2025FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB03/05/2025FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB02/05/2025FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT EXP 1(S. ELEV) LOOSE/CRACKED MASONRY IN BETWEEN 2ND AND 3RD FLOOR. ALSO OBSERVED MISSING BRICK BELOW 3RD FLOOR WINDOW SILLS. OBSERVE SPALLED DECO$6K due
DOB01/22/2025FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB12/30/2024FULL VACATE ORDER. A PARKING GARAGE CONSIST OF 5 LVLS CELLAR, GROUND, ABOVE GROUND OF ENTIRE 4 STORY BLDG.OBSERVED HANG METAL SHEETS, ROTTED & DETERIORATED WOOD JOINTS W/O ADEQUATE SAFETY MEASURE. NOTED: UNSAFE NOTIFICTN FILED BY QPSI #UNPS-M0003436-1B-001. REMEDY: IMMEDIATLEY VAC -ATE ENTIRE PARKING GARAGE LEVEL, 1ST FLR THROUGH 4TH FLR
ECB12/07/202428-323.8 AND RCNY 103-13(5). FAILURE TO SECURE PUBLIC SAFETY AND/OR MAKE THE BUILDING'S STRUCTURE AND APPURTENANCES CONFORM TO THE PROVISIONS OF THE ADMINISTRATIVE CODE AFTER UNSAFE NOTIFICATION FILED BY QPSI #$12K due
ECB12/07/2024FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.-AT TIME OF INSPECTION OBSERVED LOOSE BRICK AT LINTEL LINE ON 2ND FLOOR, MISSING BRICK/BULGING WINDOW SILL ON 3RD FLOOR AND CRACKED MASONRY IN MULTIPLE LOCA$6K due
ECB10/01/2024FAILURE TO SUBMIT THE REQUIRED PARKING STRUCTURE INITIAL OBSERVATION REPORT FOR AN EXISTING PARKING STRUCTURE OR A PERIODIC INSPECTION OF A PARKING STRUCTURE(PIPS)REPORT DOCUMENTING THE CONDITION OF PSID#M00034$12K due
ECB08/26/202428-323.8 RCNY 103-13(5)FAILURE TO SECURE PUBLIC SAFETY AND/OR MAKE THEBUILDING'S STRUCTURE AND APPURTENANCES CONFORM TO THE PROVISIONS OF ADMIN CODE AFTER UNSAFE NOTIFICATION FILED BY QPSI#UNPS-M0003436-1B-001.$2K due
ECB08/26/2024FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.NOTE:AT TIME OF INSPECTION,I OBSERVED AT EXP#1 SOUTH LOOSE BRICK LINTEL LINE OF 2 FLWL S1.MISSING BRICK/HULGING WINDOWSILL 3 FL WL S1 CRACKED BRICK MULTI$1K due
DOB08/26/2024EMERGENCY WORK ORDER, LOOSE/MASONRY/LOOSE FE TREAD.EXP1 SOUTH,I)LOOSE BRICK LINTEL LINE OF 2FL,II MISSING BRICK/BULGING WINDOW SILL 3FL WL S1,III LOOSE FE TREAD 3FL,EXP2 WEST,LOOSE SPALLING BRICK WITH INWARD LEASNING PARAPET.REMEDY:OWNER IMMEDIATELY UNDER DIRECTION OF RDP REPAIR FIRE ESC.TAKE/PROVIDE SAFETY MEASURES TO SECURE/PROTECT PUBLIC
ECB08/26/2024FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY NOTE:AT TIME OF INSPECTION I OBSERVED A LOOSE/HANGING FE TREAD AT 3 FL LEVEL CREATING A SERIOUS HAZARD IN AN EMERGENCY SITUATION AND RENDERING FE UNSAFE.REM:REPAI$1K due
ECB08/19/2024AT TIME OF INSPECTION OBSERVED A 4 STORY PARKING LOT. OBSERVED CHIP PAINTING ON BRICKS AT EXPOSURE #1. ALSO OBSERVED MISSING BRICKS UNDER WINDOW SILL AT 3RD FLOOR AND A STEP CRACK ON BRICKS BETWEEN 2ND AND 3RD$6K due
ECB11/16/2023UPON INSPECTION OBSERVED AT CELLAR LEVEL, MULTIPLE SHEET-ROCKED ENCASED COLUMNS ARE IN DISREPAIR DUE TO THE FRAMING BEING CRACKED, BROKEN, AND LEAVING THE SUPPORT COLUMNS EXPOSED. ALSO OBSERVED AT VARIOUS LOCAT$6K due
ECB10/27/2023UPON INSPECTION OBSERVED AT THE 1FLR REAR EMERGENCY EXIT, ROLLED DOWN GATE IS INSTALLED OBSTRUCTING THE EGRESS. THE 2FLR, 3FLR & 4FLR EXIT PASSAGEWAY TO THE STAIRCASE ARE OBSTRUCTED BY VEHICLES AND CREATING A D$6K due
DOB09/05/2018FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB08/09/2018FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB08/09/2018FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB01/03/2017VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST
DOB05/30/2014VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2012 CAT 1 INSP/TST
DOB02/27/2009V-DOB VIOLATION - ACTIVE
DOB03/21/2008V-DOB VIOLATION - ACTIVE
DOB06/28/19931
DOB10/12/19891
ECB06/22/2026NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 FAILURE-TO-MAINTAIN VIOLATION #39098328P ISSUED 10/27/2023 CITING DISREPAIR OF SHEETROCK-ENCASED COLUMNS AT CELLAR LEVEL AND OPENED CEILING AREAS AT THE 2ND ANDHearing held — result not yet published$1K proposed
ECB06/22/2026NO ACCESS. NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 VIOLATION #39122363H ISSUED 8/19/2024 CITING PAINT DETERIORATION, MISSING BRICK BELOW A 3RD-STORY WINDOW SILL, CRACKED BEAMS, AND STEP CRACKS AT EXPOSHearing held — result not yet published$1K proposed
ECB06/22/2026NO ACCESS. NO CERTIFICATE OF CORRECTION ON FILE FOR VIOLATION #39098225M ISSUED 10/27/2023 FOR FAILURE TO PROVIDE UNOBSTRUCTED EGRESS. VIOLATION CITES A GATE OBSTRUCTING THE 1ST-FLOOR REAR EMERGENCY EXIT AND OBHearing held — result not yet published$1K proposed
ECB06/12/2018FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NO FIRE STOPPING PER BC 712.3;27-345. NOTED: AT CELLAR LEVEL,THERE ARE SEVERAL OPENINGS AT CEILING EXPOSING FLOOR JOIST & ELIMINATING FIRE STOPPING.Nothing owed — awaiting certificate of correction
ECB05/18/2018FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER-NOTED:AT CELLAR THERE IS APPROX 25'X18'OF AREA THAT WAS INSTALLED WITH SHEET METAL FORFIRESTOPPING BUT IT DOES NOT CONNECT END TO END.YOU CAN SEE FLOOR JOISNothing owed — awaiting certificate of correction
ECB05/18/2018FILED A CERTIFICATE OR OTHER RELATED MATERIALS CONTAINING MATERIAL FALSE STATEMENTS.ORIGINAL EXB#34980880P ISSUED 06/26/2012 WAS ISSUED AND THE CERTIFICATE OF CORRECTION WAS ACCEPTED ON 2/21/2018 I OBSERVED @Nothing owed — awaiting certificate of correction
ECB02/21/20171-ERECT AWNING,APPRX 10'WIDE X 4'HIGH X 3'OVERHANG WITH FLUORESCENT FIXTURE UNDER IT AND INSCRIPTION "PARKING 24 HOURS"; 2-ERECT ILLUMINATEDSIGN APPRX 12'WIDE X 3'HIGH WITH INSCRIPTION "VFC PARKING"; 3-ERECT 2WNothing owed — awaiting certificate of correction