← Back
Two family brick
473 WEST 144 STREET
MANHATTAN · BIN 1061302
💬 Discuss this project
1896Year Built
3Stories
B1Building Class
R6AZoning
3,972 sfGross Floor Area
2Units
Rent Stabilized16 Open Violations ▸
Two family brick · 1,749 sf lot · 2.27 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 31p · 1 filing · 12 docs
Floor 2
Floor 1
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ORGANISATION ARCHITECTURE310/23/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
G. & S. PLUMBING & HTG COPlumbing207/08/2026
Building Lifecycle
All (68)Filed (3)Permit Issued (2)Signed Off (2)Violation (54)Inspection (5)Objection (2)
08/26/2026
Violation issued (HPD, open)
C
08/26/2026
Violation issued (HPD, open)
A
05/14/2026
Violation issued (HPD, open)
A
05/14/2026
Violation issued (HPD, open)
B
03/18/2026
Violation issued (HPD, open)
B
03/18/2026
Violation issued (HPD, open)
A
03/18/2026
Violation issued (HPD, closed)
A
02/07/2026
Violation issued (HPD, open)
C
02/07/2026
Violation issued (HPD, open)
B
02/07/2026
Violation issued (HPD, closed)
A
02/07/2026
Violation issued (HPD, open)
B
02/07/2026
Violation issued (HPD, open)
B
01/28/2026
Violation issued (HPD, open)
C
01/13/2026
Violation issued (HPD, open)
B
01/13/2026
Violation issued (HPD, open)
B
01/13/2026
Violation issued (HPD, closed)
A
05/28/2025
Violation issued (HPD, closed)
I
05/23/2025
Violation issued (HPD, open)
C
02/03/2025
Violation issued (HPD, open)
A
02/03/2025
Violation issued (HPD, open)
C
02/03/2025
Violation issued (HPD, closed)
I
01/31/2025
Violation issued (HPD, closed)
C
04/02/2024
Violation issued (HPD, closed)
A
11/06/2023
Signed off — Alteration
Job filed to correct the Scope of Work on Job # M00843823-i1. Gas work shown on that filing is incorrect. Gas Riser to 3rd floor is to be capped. No gas equipment on 3rd Floor.
M00843823-I1
11/03/2023
Signed off — Alteration
Job filed to correct the Scope of Work on Job # M00843823-i1. Gas work shown on that filing is incorrect. Gas Riser to 3rd floor is to be capped. No gas equipment on 3rd Floor.
M00843823-S1
10/23/2023
Filed — Alteration
Job filed to correct the Scope of Work on Job # M00843823-i1. Gas work shown on that filing is incorrect. Gas Riser to 3rd floor is to be capped. No gas equipment on 3rd Floor.
M00843823-P1
08/14/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
08/14/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
08/01/2023
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
07/11/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/05/2023
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
06/02/2023
Permit issued — Plumbing
M00843823-S1-PL
05/11/2023
Filed — Alteration
Job filed to correct the Scope of Work on Job # M00843823-i1. Gas work shown on that filing is incorrect. Gas Riser to 3rd floor is to be capped. No gas equipment on 3rd Floor.
M00843823-S1
05/01/2023
Permit issued — Plumbing
M00843823-I1-PL
04/25/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/27/2023
Objection raised — Scope
03/27/2023
Objection resolved — Addressed
03/23/2023
Filed — Alteration
Job filed to correct the Scope of Work on Job # M00843823-i1. Gas work shown on that filing is incorrect. Gas Riser to 3rd floor is to be capped. No gas equipment on 3rd Floor.
M00843823-I1
03/16/2023
Violation issued (HPD, closed)
A
07/21/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/07/2022
Violation issued (HPD, closed)
B
03/07/2022
Violation issued (HPD, closed)
B
03/07/2022
Violation issued (HPD, closed)
B
03/07/2022
Violation issued (HPD, closed)
B
03/07/2022
Violation issued (HPD, closed)
B
03/07/2022
Violation issued (HPD, closed)
C
03/07/2022
Violation issued (HPD, closed)
C
03/07/2022
Violation issued (HPD, closed)
A
03/07/2022
Violation issued (HPD, closed)
B
03/07/2022
Violation issued (HPD, closed)
B
03/07/2022
Violation issued (HPD, closed)
B
02/16/2022
Violation issued (HPD, closed)
A
10/30/2020
Violation issued (ECB, closed)
Construction
08/25/2020
Violation issued (ECB, closed)
Construction
03/03/2020
Violation issued (ECB, closed)
Construction
02/05/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/05/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/26/2019
Violation issued (ECB, closed)
Construction
12/26/2019
Violation issued (ECB, closed)
Construction
11/12/2019
Violation issued (ECB, closed)
Construction
Latest 60 of 68 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offG. & S. PLUMBING & HTG CO06/02/2023
DOB NOWPlumbingSigned-offG. & S. PLUMBING & HTG CO05/01/2023
BIS—ISSUEDBSD CORP. KINGS06/06/2022
1 project · most recent 09/29/2022
General Wiring
FiledStatusContractorScope
09/29/2022CompleteHI-NRG ELECTRIC CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
08/14/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
08/14/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
08/01/2023Fail-Final PL - Up to 3 Requested FloorsFailView ↗
07/11/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/05/2023Fail-Final PL - Up to 3 Requested FloorsFailView ↗
▾Documents — 48 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/31/2026M00843823-P1Request digital key ↗
08/31/2026M00843823-S1Request digital key ↗
08/14/2026M00843823-I1Request digital key ↗
▸Applications & Permits11
▸BISPLAN / WORK APPROVAL APPLICATION5
02/16/2024123904668Open ↗
02/06/2024123904668Open ↗
03/31/2023123904668Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWLPC Approval/Permit3
08/13/2026M00843823-P1Open ↗
08/13/2026M00843823-I1Open ↗
08/13/2026M00843823-S1Open ↗
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
11/29/2021123904668Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
07/05/2022123904668Open ↗
▸BISWORK PERMIT APPLICATION1
06/07/2022123904668Open ↗
▸Seals & Professional Certifications3
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/13/2026M00843823-P1Open ↗
08/13/2026M00843823-S1Open ↗
08/13/2026M00843823-I1Open ↗
▸Safety & Tenant Protection7
▸DOB NOWHPD-3: Single Room Occupancy Multiple Dwelling (SRO MD) Anti-Harassment Checklist3
08/13/2026M00843823-P1Open ↗
08/13/2026M00843823-I1Open ↗
08/13/2026M00843823-S1Open ↗
▸BISHPD: SRO MD CERTIFICATE OF NO HARASSMENT1
11/29/2021123904668Open ↗
▸BISSTREET TREE CHECKLIST1
02/09/2021123904668Open ↗
▸BISSTREET TREE SIGNOFF1
07/12/2022123904668Open ↗
▸BISTPP1: TENANT PROTECTION PLAN1
05/26/2022123904668Open ↗
▸Environmental & Asbestos1
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
02/06/2024123904668Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
01/18/2023123904668Open ↗
02/09/2021123904668Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
07/14/2022123904668Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY2
03/17/2023123904668Open ↗
02/09/2021123904668Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
11/30/2023123904668Open ↗
▸Approvals, Objections & Sign-offs9
▸BISLETTERS - SUPPORTING DOCUMENTATION5
04/26/2023123904668Open ↗
04/26/2023123904668Open ↗
04/26/2023123904668Open ↗
Showing 3 of 5 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE2
03/31/2023123904668Open ↗
02/09/2021123904668Open ↗
▸BISLANDMARKS APPROVAL1
11/29/2021123904668Open ↗
▸BISLANDMARKS SIGNOFF1
07/13/2022123904668Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT2
03/17/2023123904668Open ↗
11/29/2021123904668Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
07/08/2022123904668Open ↗
▸Filing & Intake Forms4
▸BISADDITIONAL INFORMATION3
04/26/2023123904668Open ↗
01/19/2022123904668Open ↗
12/15/2021123904668Open ↗
▸BISEFILING COVER SHEET1
12/14/2020123904668Open ↗
▸Other Documents1
▸BISPLOT DIAGRAM1
02/09/2021123904668Open ↗