← Back
Condo, residential tower (mixed-use, multi-family elevator) [derived]
165 WEST 95 STREET
MANHATTAN · BIN 1070983
💬 Discuss this project
1900Year Built
3Stories
RMBuilding Class
R7-2Zoning
5,761 sfGross Floor Area
8Units
Rent Stabilized10 Open Violations ▸
Condo, residential tower (mixed-use, multi-family elevator) [derived] · 1,800 sf lot · 3.2 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
DIPROPERZIO & MALLIA ARCHITECTS,LLP110/31/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RMR RENOVATIONS INCGeneral Contractor303/21/2026
FRED SMITH P&H CO INCPlumbing203/22/2026
LEFKES WATER WORKS INCPlumbing103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DIPROPERZIO & MALLIA, LLP7517110/31/2022
Building Lifecycle
All (33)Filed (1)Permit Issued (1)Signed Off (1)Violation (23)Special Inspection (7)
04/29/2026
Violation issued (HPD, open)
A
11/17/2025
Violation issued (HPD, closed)
I
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/04/2025
Violation issued (HPD, open)
A
11/22/2024
Violation issued (HPD, closed)
I
06/27/2024
Signed off — Alteration
M08029963-I1
04/01/2024
Violation issued (HPD, open)
A
03/07/2024
Permit issued — General Construction
M08029963-I1-GC
11/15/2023
Violation issued (HPD, closed)
I
03/16/2023
Violation issued (HPD, open)
A
10/31/2022
Filed — Alteration
M08029963-I1
10/28/2022
Special inspection requirement — Fenestration air leakage
Michael Mallia
10/28/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
Michael Mallia
10/28/2022
Special inspection requirement — Concrete - Cast-In-Place
Michael Mallia
10/28/2022
Special inspection requirement — Energy Code Compliance Inspections
Michael Mallia
10/28/2022
Special inspection requirement — Fire-Resistance Rated Construction
Michael Mallia
10/28/2022
Special inspection requirement — Preliminary
Michael Mallia
10/28/2022
Special inspection requirement — Final
Michael Mallia
02/16/2022
Violation issued (HPD, open)
A
04/01/2021
Violation issued (HPD, closed)
A
11/06/2017
Violation issued (HPD, closed)
I
11/06/2016
Violation issued (HPD, open)
A
10/26/2016
Violation issued (HPD, closed)
I
10/02/2015
Violation issued (HPD, closed)
I
04/08/2015
Violation issued (HPD, open)
B
03/03/2015
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/03/2015
Violation issued (HPD, closed)
I
05/15/2014
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/07/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/16/1999
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/04/1998
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/10/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/01/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offRMR RENOVATIONS INC03/07/2024
BISPLISSUEDLEFKES WATER WORKS INC08/12/2016
BISOTISSUEDFIVE BORO CONTRACTING INC08/05/2016
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
10/28/2022Fenestration air leakageMichael Malliaenergy_progress
10/28/2022Fenestration and door U-factor and product ratingsMichael Malliaenergy_progress
10/28/2022Concrete - Cast-In-PlaceMichael Malliaspecial
10/28/2022Energy Code Compliance InspectionsMichael Malliaprogress
10/28/2022Fire-Resistance Rated ConstructionMichael Malliaprogress
10/28/2022PreliminaryMichael Malliaprogress
10/28/2022FinalMichael Malliaprogress
▾Documents — 25 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
09/01/2026M08029963-I1Request digital key ↗
▸Applications & Permits5
▸BISPLAN / WORK APPROVAL APPLICATION3
04/12/2017122738234Open ↗
08/10/2016122738234Open ↗
07/19/2016122738234Open ↗
▸BISWORK PERMIT APPLICATION2
08/23/2016122738234Open ↗
08/10/2016122738234Open ↗
▸Seals & Professional Certifications12
▸DOB NOWProgress Inspector Seal & Signature6
09/23/2026M08029963-I1Open ↗
09/23/2026M08029963-I1Open ↗
09/23/2026M08029963-I1Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
08/10/2016122738234Open ↗
07/19/2016122738234Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
07/19/2016122738234Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
07/19/2016122738234Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026M08029963-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/23/2026M08029963-I1Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
07/19/2016122738234Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
07/19/2016122738234Open ↗
▸Environmental & Asbestos1
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
08/10/2016122738234Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
08/10/2016122738234Open ↗
07/19/2016122738234Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
08/10/2016122738234Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
07/19/2016122738234Open ↗