← Back
Church, synagogue, chapel
Elmendorf Reformed Church
169 EAST 121 STREET · BIN 1074330
💬 Discuss this project
1900Year Built
2Stories
M1Building Class
R7BZoning
8,668 sfGross Floor Area
1Units
10 Open Violations 7 unresolved · 3 paperwork only ▸
Church, synagogue, chapel · 6,249 sf lot · 1.39 FAR built · Flood zone X
Locations of Work
MechanicalPlumbing
Floor 11p · 1 filing · 5 docs
Cellar1p · 1 filing · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ELMENDORF REFORMED CHURCH1307/08/2026
CHURCH OF HAARLEM203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ISSA KHORASANCHI P.E.304/26/2023
ARCHITECTURE DESIGN, PLLC110/30/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KSTM EXPEDIRING SERVICES403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TRIPLE CROWN PLBG&HTG INCPlumbing607/08/2026
MICHAEL MIRINOElectrical103/21/2026
GARDEN STATE OF NJ DATA*General Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AA BUILDING & INSPECTION1519104/26/2023
IP CONCRETE TESTING AND I6252104/26/2023
Building Lifecycle
All (27)Filed (4)Permit Issued (7)Violation (11)Special Inspection (5)
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
10/03/2023
Permit issued — Plumbing
M00210260-I1-PL
09/22/2023
Permit issued — Mechanical Systems
M00855259-I1-MS
04/26/2023
Filed — Alteration
PROPOSED 7'-0" x 3'-6" STAINLESS STEEL HOOD WITH SIDE WALL EXHAUST FAN DISCHARGE TO AN EXISTING COOKING / PREP AREA AT REAR OF AN EXISTING HOUSE OF WORSHIP AS PER PLANS FILED HEREWITH. NO PROPOSED CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
M00855259-I1
04/26/2023
Filed — Alteration
PROPOSE REPLACEMENT OF GAS/OIL BOILER AND (2) 275 GALLON OIL TANKS WITHIN CELLAR FLOOR AS PER PLANS FILED HEREWITH. THERE IS NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
M00855277-I1
04/05/2023
Special inspection requirement — Mechanical Systems
Younes Abouyaala
04/05/2023
Special inspection requirement — Final
ISSA KHORASANCHI
03/08/2023
Permit issued — Plumbing
M00210260-I1-PL
01/25/2023
Permit issued — Plumbing
M00210260-I1-PL
01/28/2021
Permit issued — Plumbing
M00210260-I1-PL
03/26/2020
Permit issued — Plumbing
M00210260-I1-PL
11/26/2019
Permit issued — Plumbing
M00210260-I1-PL
11/08/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/30/2019
Filed — Alteration
PROPOSE RELOCATION OF GAS METER AND ASSOCIATED GAS PIPING TO SERVE NEW COMMERCIAL BOILER FILED UNDER SEPARATE APPLICATION. THERE IS NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
M00210260-I1
10/30/2019
Filed — Alteration
M00240413-I1
10/04/2019
Special inspection requirement — Fuel-Oil Storage and Fuel-Oil Piping Systems
10/04/2019
Special inspection requirement — Fire-Resistant Penetrations and Joints
10/04/2019
Special inspection requirement — Maintenance information
JOSE CONCEPCION
03/24/1994
Violation issued (ECB, open)
Construction
03/18/1994
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
07/30/1993
Violation issued (ECB, open)
Public Assembly
07/30/1993
Violation issued (ECB, open)
Construction
06/28/1993
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/28/1993
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/28/1993
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/18/1993
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedTRIPLE CROWN PLBG&HTG INC10/03/2023
DOB NOWMechanical SystemsPermit IssuedGARDEN STATE OF NJ DATA*09/22/2023
DOB NOWPlumbingPermit IssuedTRIPLE CROWN PLBG&HTG INC03/08/2023
DOB NOWPlumbingPermit IssuedTRIPLE CROWN PLBG&HTG INC01/25/2023
DOB NOWPlumbingPermit IssuedTRIPLE CROWN PLBG&HTG INC01/28/2021
DOB NOWPlumbingPermit IssuedTRIPLE CROWN PLBG&HTG INC03/26/2020
DOB NOWPlumbingPermit IssuedTRIPLE CROWN PLBG&HTG INC11/26/2019
BISFSISSUEDJACK PICCINI, INC09/25/2008
BISFPISSUEDIDEAL FIRE CONTROL07/19/1994
1 project · most recent 04/26/2023
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
04/26/2023Permit IssuedGARDEN STATE OF NJ DATA*Ventilation Systems
Ventilation
Dayton MODEL# 6D598 1,260 CFM ×1
1 project · most recent 10/30/2019
Gas
FiledStatusContractorScope
10/30/2019Permit IssuedTRIPLE CROWN PLBG&HTG INCGas
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
04/05/2023Mechanical SystemsYounes Abouyaalaspecial
04/05/2023FinalISSA KHORASANCHIprogress
10/04/2019Fuel-Oil Storage and Fuel-Oil Piping Systems—special
10/04/2019Fire-Resistant Penetrations and Joints—special
10/04/2019Maintenance informationJOSE CONCEPCIONenergy_progress
▾Documents — 32 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch2
08/31/2026M00855259-I1Request digital key ↗
08/31/2026M00855277-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Boiler Equipment1
09/05/2026M00240413-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing1
09/05/2026M00210260-I1Request digital key ↗
▸Applications & Permits3
▸BISPLAN / WORK APPROVAL APPLICATION2
03/17/2017123054210Open ↗
09/22/2008110252011Open ↗
▸BISWORK PERMIT APPLICATION1
09/25/2008110252011Open ↗
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/31/2026M00855277-I1Open ↗
08/13/2026M00210260-I1Open ↗
08/13/2026M00855259-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
11/28/2008110252011Open ↗
09/22/2008110252011Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
09/22/2008110252011Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
09/22/2008110252011Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/25/2026M00855259-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/25/2026M00855259-I1Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
09/22/2008110252011Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/31/2026M00855277-I1Open ↗
08/13/2026M00210260-I1Open ↗
08/13/2026M00240413-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
09/22/2008110252011Open ↗
▸Approvals, Objections & Sign-offs3
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
11/28/2008110252011Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
09/22/2008110252011Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
11/28/2008110252011Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
03/17/2017123054210Open ↗
11/28/2008110252011Open ↗
09/22/2008110252011Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET2
03/17/2017123054210Open ↗
09/22/2008110252011Open ↗
▸Other Documents1
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
03/17/2017123054210Open ↗