← Back
Converted dwellings or rooming house
23 WEST 90 STREET
MANHATTAN · BIN 1081756
💬 Discuss this project
1910Year Built
4Stories
C5Building Class
R7-2Zoning
76,968 sfGross Floor Area
96Units
LL97 Covered14 Open Violations ▸
Converted dwellings or rooming house · Owner of record: NYC HOUSING AUTHORITY · 29,105 sf lot · 2.64 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalCivilGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction16p · 1 filing · 17 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NYCHA807/08/2026
NEW YORK CITY HOUSING AUTHORITY603/22/2026
NYC HOUSING AUTHORITY103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JOEL PHAGOO P.E. PLLC408/29/2025
STV INCORPORATED308/08/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
STV603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ZORIA HOUSING, LLCGeneral Contractor407/08/2026
CPH PIPELINE OF N Y INCElectrical203/21/2026
JEFFREY, DARRINElectrical203/21/2026
MIRINO, MICHAELElectrical203/21/2026
MICHAEL MIRINOElectrical103/21/2026
J.K.CONSTRUCTION NEW YORKGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JOEL PHAGOO ,PE, PLLC2416108/06/2025
ALAN MARGOLIN & ASSOC423210/14/2022
Building Lifecycle
All (24)Filed (7)Permit Issued (4)Signed Off (3)Special Inspection (10)
01/15/2026
Signed off — Alteration
INSTALLATION OF TEMPORARY CHAIN LINK FENCE AS PER PLANS. CHAIN LINK FENCE SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
M01260507-I1
01/15/2026
Signed off — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLANS. SIDEWALK SHED SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
M01260441-I1
01/15/2026
Signed off — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. PIPE SCAFFOLD SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
M01266647-I1
08/29/2025
Filed — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLANS. SIDEWALK SHED SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
M01260441-P1
08/14/2025
Permit issued — Structural
M08012270-I1-GC-CX
08/08/2025
Filed — Alteration
WSUR BLDG28_Roof Roofing Replacement and Rooftop Structure Renovation.
M08012270-P2
08/07/2025
Permit issued — Supported Scaffold
M01266647-I1-SF
08/06/2025
Filed — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. PIPE SCAFFOLD SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
M01266647-I1
08/05/2025
Special inspection requirement — Post-installed Anchors
JOEL PHAGOO
08/01/2025
Permit issued — Construction Fence
M01260507-I1-FN
08/01/2025
Permit issued — Sidewalk Shed
M01260441-I1-SH
07/31/2025
Filed — Alteration
INSTALLATION OF TEMPORARY CHAIN LINK FENCE AS PER PLANS. CHAIN LINK FENCE SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
M01260507-I1
07/31/2025
Filed — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLANS. SIDEWALK SHED SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
M01260441-I1
06/17/2025
Special inspection requirement — Wood – Seismic Resistance
06/09/2025
Special inspection requirement — Structural Steel - Welding
06/09/2025
Special inspection requirement — Masonry
06/09/2025
Special inspection requirement — Final
06/09/2025
Special inspection requirement — Structural Wood Frame
07/15/2024
Filed — Alteration
WSUR BLDG28_Roof Roofing Replacement and Rooftop Structure Renovation.
M08012270-P1
05/01/2024
Special inspection requirement — Final
05/01/2024
Special inspection requirement — Structural Wood Frame
05/01/2024
Special inspection requirement — Structural Steel - Welding
05/01/2024
Special inspection requirement — Masonry
10/14/2022
Filed — Alteration
WSUR BLDG28_Roof Roofing Replacement and Rooftop Structure Renovation.
M08012270-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedZORIA HOUSING, LLC08/14/2025
DOB NOWSupported ScaffoldSigned-offZORIA HOUSING, LLC08/07/2025
DOB NOWConstruction FenceSigned-offZORIA HOUSING, LLC08/01/2025
DOB NOWSidewalk ShedSigned-offJ.K.CONSTRUCTION NEW YORK08/01/2025
BISPLISSUEDDELPHI PLBG. & HTG., INC09/04/2007
1 job · most recent 07/21/2025
FiledStatusContractorScope
07/21/2025CompleteAUJLA ELECTRIC CORP—
1 job · most recent 08/08/2025
Wood
FiledStatusContractorScope
08/08/2025Permit IssuedZORIA HOUSING, LLCWood
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
08/05/2025Post-installed AnchorsJOEL PHAGOOspecial
06/17/2025Wood – Seismic Resistance—special
06/09/2025Structural Steel - Welding—special
06/09/2025Masonry—special
06/09/2025Final—progress
06/09/2025Structural Wood Frame—progress
05/01/2024Final—progress
05/01/2024Structural Wood Frame—progress
05/01/2024Structural Steel - Welding—special
05/01/2024Masonry—special
▾Documents — 30 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/22/2026M01260507-I1Request digital key ↗
08/22/2026M01266647-I1Request digital key ↗
08/22/2026M08012270-I1Request digital key ↗
Showing 3 of 7 on file for this type
▸Applications & Permits3
▸DOB NOWLPC Approval/Permit3
08/13/2026M08012270-P2Open ↗
08/13/2026M08012270-I1Open ↗
08/13/2026M08012270-P1Open ↗
▸Seals & Professional Certifications8
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/22/2026M01260507-I1Open ↗
08/22/2026M08012270-I1Open ↗
08/22/2026M08012270-P2Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature1
08/27/2026M01266647-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/22/2026M08012270-I1Open ↗
08/22/2026M08012270-P2Open ↗
▸Approvals, Objections & Sign-offs7
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter7
08/22/2026M08012270-I1Open ↗
08/22/2026M08012270-P1Open ↗
08/22/2026M08012270-P2Open ↗
Showing 3 of 7 on file for this type
▸Other Documents3
▸DOB NOWProof of Historic Building3
08/13/2026M08012270-P1Open ↗
08/13/2026M08012270-P2Open ↗
08/13/2026M08012270-I1Open ↗