← Back
Hospital, sanitarium, mental institution
1091 AMSTERDAM AVENUE
MANHATTAN · BIN 1084032
💬 Discuss this project
1954Year Built
13Stories
I1Building Class
R8Zoning
511,567 sfGross Floor Area
1Units
LL97 Covered4 Open Violations 0 unresolved · 4 paperwork only ▸FISP: SWARMP
Hospital, sanitarium, mental institution · Owner of record: ST LUKE'S/ROOSEVELT HOSPITAL · 64,954 sf lot · 7.88 FAR built · Flood zone X
Locations of Work
Architecture
Roof1p · 1 filing · 9 docs
1 job · most recent 02/17/2022
FiledStatusContractorScope
02/17/2022Permit IssuedE-J ELEC. INSTALLATION CO—
Building Lifecycle
All (30)Filed (2)Permit Issued (4)Signed Off (2)Facade (FISP) (16)Violation (1)Special Inspection (5)
10/23/2023
Signed off — Alteration
Herewith filing Facade and Roof Renovations for Mount Sinai Muhlenberg Building. No change to use, egress, or occupancy.
M00550316-I1
08/17/2023
Violation issued (ECB, open)
Construction
05/03/2023
Permit issued — General Construction
M00550316-I1-GC
11/09/2022
Signed off — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00724346-I1
10/01/2022
Cycle 9 facade report signed — SWARMP
05/04/2022
Filed — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00724346-I1
05/04/2022
Permit issued — Supported Scaffold
M00724346-I1-SF
04/08/2022
Permit issued — General Construction
M00550316-I1-GC
03/28/2022
Cycle 9 facade report submitted
03/15/2022
Cycle 8 facade report signed — SAFE
02/22/2022
Cycle 8 facade report submitted
02/18/2022
Cycle 9 facade inspection completed
02/12/2022
Cycle 8 facade inspection completed
09/10/2021
Permit issued — General Construction
M00550316-I1-GC
07/06/2021
Filed — Alteration
Herewith filing Facade and Roof Renovations for Mount Sinai Muhlenberg Building. No change to use, egress, or occupancy.
M00550316-I1
06/30/2021
Special inspection requirement — Masonry
Young Suh
06/30/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
Young Suh
06/30/2021
Special inspection requirement — Final
Young Suh
06/30/2021
Special inspection requirement — Energy Code Compliance Inspections
Young Suh
06/30/2021
Special inspection requirement — Air barrier - visual inspection
Young Suh
02/21/2017
Cycle 8 facade report submitted
02/17/2017
Cycle 8 facade report signed — UNSAFE
02/13/2017
Cycle 8 facade inspection completed
10/15/2013
Cycle 7 facade report submitted
07/27/2011
Cycle 7 facade report submitted
07/19/2011
Cycle 7 facade report signed — UNSAFE
06/06/2011
Cycle 7 facade inspection completed
06/14/2006
Cycle 6 facade report submitted
06/06/2006
Cycle 6 facade report signed — SAFE
12/08/2005
Cycle 6 facade inspection completed
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ST LUKE'S/ROOSEVELT HOSPITAL203/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PAUL PERDEK, PROF. ENG. PLLC105/04/2022
ARCHITECTURAL PRESERVATION STUDIO,107/06/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AE DESIGN SOLUTION203/21/2026
OUTSOURCE CONSULTANTS, INC.203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
B & A RESTORATION CONTRAGeneral Contractor507/08/2026
SPRING SCAFFOLDING LLCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ALAN MARGOLIN & ASSOC423107/06/2021
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offB & A RESTORATION CONTRA05/03/2023
DOB NOWSupported ScaffoldSigned-offSPRING SCAFFOLDING LLC05/04/2022
DOB NOWGeneral ConstructionSigned-offB & A RESTORATION CONTRA04/08/2022
DOB NOWGeneral ConstructionSigned-offB & A RESTORATION CONTRA09/10/2021
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
06/30/2021MasonryYoung Suhspecial
06/30/2021Structural Stability – Alterations of existing buildingsYoung Suhspecial
06/30/2021FinalYoung Suhprogress
06/30/2021Energy Code Compliance InspectionsYoung Suhprogress
06/30/2021Air barrier - visual inspectionYoung Suhenergy_progress
▾Documents — 12 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
09/03/2026M00550316-I1Request digital key ↗
09/02/2026M00724346-I1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026M00550316-I1Open ↗
08/13/2026M00724346-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/26/2026M00550316-I1Open ↗
08/26/2026M00550316-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/26/2026M00550316-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form1
08/13/2026M00550316-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026M00550316-I1Open ↗
▸Approvals, Objections & Sign-offs3
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter2
08/13/2026M00724346-I1Open ↗
08/13/2026M00550316-I1Open ↗
▸DOB NOWDEP Variance (V5) letter1
08/13/2026M00550316-I1Open ↗