HPD08/26/2026§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FEET AT CEILING IN THE BATHROOM LOCATED AT APT 29H, 29th STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD08/26/2026§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE BATHROOM LOCATED AT APT 29H, 29th STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD08/26/2026§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL IN THE BATHROOM LOCATED AT APT 29H, 29th STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD07/28/2026§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 37A, 37th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD07/28/2026§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 37A, 37th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD05/13/2026HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3W, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''NORTH''
HPD05/13/2026§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 3W, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''NORTH''
HPD04/29/2026(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
HPD04/21/2026HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 4th APARTMENT FROM NORTH AT EAST
ECB01/21/2026VF.. HOIST MACHINE BRAKE MAINTENANCE TAG EXPIRED , PROVIDE.. 59-BB-7...$3K due
ECB01/21/2026VF... HOIST MACHINE BRAKE MAINTENANCE TAG EXPIRED PROVIDE... 59-BB-7...$3K due
ECB12/30/2025AT TIME OF INSPECTON I OBSERVED SIDEWALK SHED INSTALLED ON EXPOSURE # 1 AND 4 WITHOUT SIGNS OR PROJECT INFORMATION PANEL ON THE SHED PARAPET, TO DISPLAY THE NAME AND THE CONTACT INFORMATION OF THE OWNER OR THE$6K due
HPD12/24/2025HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 19D, 19th STORY, 2nd APARTMENT FROM WEST AT NORTH
ECB12/22/2025FAILURE TO REPAIR AND MAINTAIN SIDEWALK SHED AS PER CODE REQUIREMENTS. OBSERVED DETACHED AND MISSING PARAPET PANELS FOR SHED AT EXPOSURE 4, CREATING HAZARDOUS TO PUBLIC, AND IN CONTRARY WITH CODE 3307.6.4.6 PAR$10K due
HPD12/08/2025§ 27-2005, 2012 HMC & § 309 MDL: ABATE THE NUISANCE CONSISTING OF EXCESSIVE STORAGE OF MATERIAL BOXES AND HOUSEHOLD ITEMS IN THE ENTIRE APARTMENT LOCATED AT APT 12E, 12th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD11/20/2025§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FEET AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2M, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 18439425 ISSUED 20-NOV-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3)(a) or (b).
HPD11/20/2025§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THAN 10 SQ FEET AT CEILING AND ALL WALLS AT CLOSET IN THE BATHROOM LOCATED AT APT 2M, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
ECB11/17/2025AT TIME OF INSPECTION OF A 38 STORIES BUILDING I OBSERVED SIDEWALK SHED IN PLACE NOT MAINTAIN AS REQUIRED OBSERVED MISSING PARAPET PANELS CREATING LARGE OPENING AT EXPOSURE #1 WHICH MIGHT CAUSE MATERIAL FALLIN$10K due
ECB11/17/2025AT TIME OF INSPECTION IN RESPONSE TO A FOLLOW UP OF AN INCIDENT THAT OCCURRED ON NOVEMBER 16TH 2025 DURING HIGH WIND GUST WHERE SECTIONS OF SIDEWALK SHED PARAPET PANELS DISLODGED FROM THE SHED LANDED UNTO THE$25K due
ECB09/02/2025FAILURE TO SUBMIT CERTIFICATE OF CORRECTION FOR VIOLATION # 39074552N ISSUED ON 11/28/2022 FOR FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER, REPAIR AND/REPLACE$25K due
ECB08/05/2025NOTE: AT TIME OF INSPECTION, I OBSERVED A SWS ERECTED AT EXPO# 1 AND 4 WITH MISSING INFORMATION PANEL AS REQUIRED BY CODE (3301.9.2.1.1) WHICH INCLUDES THE BUILDING ADDRESS AND NAME OF CONTRACTOR RESPONSIBLE. N$6K due
ECB06/25/2025AT TIME OF INSPECTON I OBSERVED SIDEWALK SHED INSTALLED ON EXPOSURE # 1 AND 2 WITHOUT SIGNS OR PROJECT INFORMATION PANEL ON THE SHED PARAPET, TO DISPLAY THE NAME AND THE CONTACT INFORMATION OF THE OWNER OR THE$1K due
ECB06/12/2025REISSUE#35675001P FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.OBSERVED AT 1ST FLOOR PRE-SCHOOL PARDA ROOM EXIT DOOR LEADING TO YARD NOT SELF-CLOSING WHEN TESTED DUES TO SADDLE UPLIFT FROM CONSTRUCTION$3K due
ECB04/08/2025FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8C AND 9C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #903352. AGG1: PRIOR NOV 3702297$10K due
HPD01/31/2025§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 30 SQ FEET AT ALL WALLS IN THE BATHROOM LOCATED AT APT 2M, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
HPD01/26/2025§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 39H, 39th STORY, 1st APARTMENT FROM WEST AT NORTH
HPD12/11/2024HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 31D, 31st STORY, 2nd APARTMENT FROM WEST AT NORTH
ECB11/22/2024AT TIME OF INSPECTION OF A 39 STORIES BUILDING I OBSERVED SIDEWALK SHED NOT ADEQUATELY SECTION OF SIDEWALK SHED PARAPET WAS MISSING, INSPECTION REVEAL THAT THE 4 PANEL CAME OFF THE SHED DURING HIGH WIND LANDED$10K due
ECB09/11/202428-323.1 FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION.NOTED:ACTIVE PARKING STRUCTURE OF 3 LEVELS(BELOW GRADE).OBSERVE SPALLING CONCRETE & EXPOSED REBARS FROM GIRDER.ALSO OBSERVED CRACKS ON CEILING AT$6K due
ECB07/31/2024UNLAWFUL ACTS. FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER. NOTE: RESPONDENT HAS FAILED TO COMPLY WITH PREVIOUS VIOL #35682562K DATED 04/12/2024 AND #35682563M DATED 04/12/2024.-AT TIME OF INSPECTION, I OBS$6K due
ECB06/21/2024FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE: (1)HAZARDOUS CONDITION OBSERVED, (1)SPALLLED CONCRETE SLAB AT 7 STORY BALCONY AT EXPOSURE #1(NORTH) (2)SPALLING CONCRETE SLAB AT 5 STORY EXP$1K due
ECB05/27/2024AT THE TIME OF THE INSPECTION FOR THE JOB SITE 39 STORIES WITH ALTERATION WITH AN ACTIVE PERMIT, THE JOB SITE WAS CLOSED, AND I OBSERVED THE GC MISSED THE PROJECT PANEL INFORMATION, WHICH SHOULD BE AT THE PARAP$6K due
HPD05/22/2024HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 7U, 7th STORY, 2nd APARTMENT FROM WEST AT NORTH , 1st SECTION FROM WEST AT NORTH
HPD05/22/2024§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLY AT DOOR LEADING TO BALCONY IN THE 3rd ROOM FROM EAST LOCATED AT APT 7U, 7th STORY, 2nd APARTMENT FROM WEST AT NORTH , 1st SECTION FROM WEST AT NORTH
HPD05/22/2024§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INTERCOM SYSTEM FROM BUILDING FRONT DESK TO WEST WALL IN THE FOYER LOCATED AT APT 7U, 7th STORY, 2nd APARTMENT FROM WEST AT NORTH , 1st SECTION FROM WEST AT NORTH
ECB04/12/202428-323.1 FAILURE TO MAINTIAN PARKING STRUCTURE IN SAFE CONDITION.AS NOTED:ON AN ACTIVE PARKING STRUCTURE CONSISTING OF 3 LEVEL(BELOW GL)BELOW 39 FL BUILDING OBSERVED SPALLED CONCRETE/EXPOSED REBAR CRACK ON CEIL$12K due
ECB04/12/2024UNLAWFUL ACTS.FAILURE TO COMPLY WITH COMMISSIONER'S ORDER.NOTE:AT THE TIME OF INSPECTION OBSERVED,RESPONDENT FAILURE TO COMPLY WITH PREVIOUSVIOLATION#112822C22-04257 DATED 11/28/2022.AS OF TODAY,OBSERVED(1)SPAL$12K due
HPD03/15/2024§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING (APPROX. 15 SQ. FT.) IN THE BATHROOM LOCATED AT APT 6R, 6th STORY, 5th APARTMENT FROM WEST AT NORTH
HPD03/15/2024HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6R, 6th STORY, 5th APARTMENT FROM WEST AT NORTH
HPD03/15/2024HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 7L, 7th STORY, 4th APARTMENT FROM EAST AT SOUTH
HPD03/15/2024HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2U, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH
DOB03/07/2024EMERGENCY WORK ORDER DUE TO IMMINENT HAZARDOUS CONDITIONS OBSERVED AT EXP1 NORTH ELEV OF BUILDING FACADE APPURTENANCES.I OBSERVED WHILE INSP ECTING,CRACK BALCONY FLOOR SLAB ON THE 7TH FL DIRECTLY ABOVE THE UPK E NTRANCE.THIS CONDITION CAN POTENTIALLY HARM THE PUBLIC PASSING THE ENT RANCE.REMEDY:PROVIDE SAFETY MEASURES SUCH AS SWS TO PROTECT ANYONE
ECB03/07/2024FAILURE TO MAINTAIN EXTERIOR BUILDING WALLS AND APPURTENANCES. AS NOTED ABOVE:-AT THE TIME OF MY INSPECTION I OBSERVED ON EXPOSURE #1 NORTH ELEVATION: IMMINENT HAZARDOUS CONDITION ON THE FLOOR BALCONY FLOOR SLA$12K due
DOB02/22/2024FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024
ECB09/25/2023AT TIME OF INSPECTION OBSERVED SECTION OF CONCRETE MISSING ON STRUCTURAL BEAM & EXPOSED ROTTEN RE-BARS ON LEVEL 01 BY THE RAMP DOWN. ALSO OBSERVED WAFFLE CEILING CONCRETE MISSING IN VARIOUS PLACE THROUGHOUT GAR$3K due
HPD08/30/2023§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 2SQ FT AT CEILING IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 6R, 6th STORY, 5th APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 16202937 ISSUED 30-AUG-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
HPD06/12/2023§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... NORTH WALL,APPROXIMATELY 10 SQUARE FEET IN THE 1st BATHROOM FROM NORTH AT EAST LOCATED AT APT 22D, 22nd STORY, 1st APARTMENT FROM WEST AT NORTH
ECB04/28/2023EXIT DOOR NOT SELF CLOSING NOTED:CZAR EXIT DOOR(LEFT SIDE)WAS NONOPERATIONAL WHEN TESTED WITH NO DOOR CHECK PROVIDED/MISSING.REM:REPAIR/REPLACE DOOR.$3K due
ECB12/23/2022OBSERVED MINOR CRACK ON JOINT LINE BETWEEN CHIMNEY CONCRETE AND STAIRWELL CINDER BLOCK WALL FROM GRADE LEVEL TO TOP OF THE BUILDING. TOP FLOOR CRACKS ARE WIDER THEN LOWER FLOORS. MOST WIDER JOINT GAP LESS THEN$625 due
ECB11/28/2022AT TIME OF INSPECTION OBSERVED 3-LEVELS GARAGE CONCRETE FLOOR IN STATE OF DISREPAIR CONDITIONS WITH CRACKS, SPALLING CONCRETE & EXPOSED REBARS THROUGHOUT INCLUDING UNDERSIDE OF RAMPS. ALSO OBSERVED HEAVY JACK H$6K due
ECB11/03/2022FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#803352.AGG1 PRIOR NOV#37018178N UNDER 2$10K due
HPD03/30/2022§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING APPROX. 12 SQ. FT. IN THE BATHROOM LOCATED AT APT 2U, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH
ECB08/11/2021FAILURE TO MAINTAIN EXTERIOR BUILDING WALLS&APPURTENANCES. NOTE-EXPOSURE#1,NORTH ELEVATION;OBSERVED CRACKED MORTAR JOINT UNDER COPING STONE AT NORTH-WEST CORNER,BULGING/DISLODGED MORTAR JOINT UNDER COPING STONE$1K due
ECB03/16/2020FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#803352.REMEDY:SUBMIT ACCEPTABLE REQUIRE$6K due
HPD11/04/2019§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX. 8 SQ FT AT THE CEILING IN THE BATHROOM LOCATED AT APT 24D, 24th STORY, 2nd APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 13418559 ISSUED 04-NOV-19 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
HPD11/04/2019§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX. 20 SQ FT AT THE CEILING AND THE WEST WALL IN THE 1st BATHROOM FROM EAST LOCATED AT APT 27B, 27th STORY, 1st APARTMENT FROM EAST AT SOUTH
DOB04/30/2019FAILED TO FILE FISP CYCLE 8C TECHNICAL REPORT BY 02/21/2019
DOB01/15/2014FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB11/30/2011FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
HPD06/10/1996§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF UNSEALED AIR CONDITIONER OPENING 11 STY NORTHEAST APT 11C NORTH ROOM. , SECTION '' ''
HPD06/10/1996§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING 11 STY NORTHEAST APT 11C A HOLHENS. , SECTION '' ''
ECB01/23/2023AFTER INCIDENT OCCURRED BY CARBON MONOXIDE, I REQUESTED TO REVIEW THE SITE SAFETY PLAN AND VENTILATION PLAN, BUT IT WAS NO DOCUMENTS KEPT ON SITE. GENERATORS AND DIESEL EQUIPMENT WERE RUNNING, CREATING AN IMMEDNothing owed — awaiting certificate of correction
ECB01/23/2023INCIDENT OCCURRED AS CARBON MONOXIDE EXCEEDED THE ALLOWABLE LIMIT. FIRE DEPARTMENT RESPONSE TO THE COMPLAINT BY NURSERY FACILITY ABOVE THE WORKING AREA. FDNY CHECK THE AIR TO FIND THAT CARBON DIOXIDE ABOVE LIMINothing owed — awaiting certificate of correction
ECB02/18/2021FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN SUMMONS/V#39011688Y ISSUED10/22/19&TO FILE CERT OF CORRECTION PURSUANT TO28.201.1&1RCNY102-01DS.ACCEPTIBLE CERT HASN'T YET BEEN FILED DESPITE RESPONDENT ENTNothing owed — awaiting certificate of correction
ECB11/12/2019WORK WITHOUT A PERMIT. NOTED, AT THE TIME OF INSPECTION OBSERVED THE AC'S EXTERNAL UNITS (6 BIG UNITS) ERECTED OUTSIDE THE BUILDING CREATING MECHANICAL ROOM ON THE SIDEWALK EXPOSURE #1 BETWEEN TWO COMMERCIAL SPNothing owed — awaiting certificate of correction
ECB08/12/2019FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #35352160X ISSUED ON 10-15-2018 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01(D)(2) AN ACCEPTIBLE CENothing owed — awaiting certificate of correction
ECB10/15/2018WORK WITHOUT A PERMIT.I OBSERVED ON THE FIRST FLOOR AREA IN THE LAUNDRY ROOM TWO SPRINKLER HEADS INSTALLED OVER THE DRYERS..ALL THE WORK ANDINSTALLATION WAS DONE WITHOUT A PERMIT.REM:OBTAIN PERMITNothing owed — awaiting certificate of correction
ECB02/12/2018FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER-NOTED:FRONT DOORS TO ENTER UPK ARE DOUBLE DOORS.ONLY ONE DOOR IS OPENING AT THE TIME OF INSPECTION.BOTH DOORS NEED TO OPEN IN CASE OF EMERGENCY.REM:REPAIR ANothing owed — awaiting certificate of correction
ECB07/12/2016FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER. NOTED: AT THE TIME OF MY INSPECTION,CRACKS IN MASONRY CEILING AT GARAGE BETWEEN LEVEL 2 & 3. REMEDY: REPAIR &/OR REPLACE.Nothing owed — awaiting certificate of correction
ECB03/08/201667L10,10H11,17H11,06B01,16P07,56Y13,67AA02,56I10,59U07,68B07. 67L10-REPAIR PHONE; 10H11-REPLACE CARDOOR GIBBS WORN; 17H11-REPLACE HW DOOR GIBBS; 06B01-ADJUST CAR DOOR SLAMMING; 16P07-DROP KEY HOLES IN B ANDNothing owed — awaiting certificate of correction
ECB07/15/201521B06,18M07,52K10,10H11,100O02,70O02. 21B06-7TH FLR INTERLOCK KEEPER ASSEMBLY REMOVE WIRE INSUFFICIENT PROPERLY SECURE; 18M07-7TH FLR DUST COVER MISSING PROVIDE; 52K10-HOIST ROPES SHOW SIGN OF ROUGE REPAIR;10H1Nothing owed — awaiting certificate of correction
ECB10/06/201207Q03,16L10,29L10,57M11,42G10,14M09,17H11,16J01,16B01,67X10,21M07,39P01,52K11,56Y13,68B07,69M07,08V01,100B#. CEASE USE ITEMS (07) DOOR DETECTOR COVER MISSING (16-29) DOORS SLAM SHUT WHEN CLOSE TO FULLY CLOSED PNothing owed — awaiting certificate of correction
ECB09/21/201102X10,71M07,67X07,70O02,77M07. 77M07-PROVIDE A LONGER TOE GUARD AS PERCHAPTER 2.2.7 APPENDIX K-3.Nothing owed — awaiting certificate of correction
ECB09/09/2011FAILURE TO MAINTAIN BLDG IN A CODE-COMPLAINT MANNER. NOTED DEFECTS AT EXPOSURE #1 FRONT FACADE AT 3RD FL & 5TH FL LEVEL TERRACES CONCRETE EDGE (BROW) IS SPALLING W/LARGE SECTIONS OF CONCRETE DISLODGE & MISSINGNothing owed — awaiting certificate of correction
Elevator apt, fireproof with stores · 52,720 sf lot · 8.95 FAR built · Flood zone X