← Back
Over six families without stores
1246 TELLER AVENUE
BRONX · BIN 2002163
💬 Discuss this project
1930Year Built
3Stories
C1Building Class
R7-1Zoning
4,095 sfGross Floor Area
10Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Over six families without stores · Owner of record: TELLER RESIDENCE LLC · 2,500 sf lot · 1.64 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire Protection
Roof35p · 1 filing · 20 docs
Floor 336p · 1 filing · 20 docs
Floor 235p · 1 filing · 20 docs
Floor 137p · 1 filing · 20 docs
1 job · most recent 03/27/2023
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
03/27/2023Signed-offMJH CONSTRUCTION CORPAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Daikin RX12AXVJU 10,900 BTU · Condensing Unit ×4
RX18AXVJU 18,000 BTU · Condensing Unit ×4
2MXS18NMVJU 18,000 BTU · Condensing Unit ×2
Heating
Daikin RX12AXVJU 13,500 BTU · Condensing Unit ×4
RX18AXVJU 21,600 BTU · Condensing Unit ×4
2MXS18NMVJU 18,900 BTU · Condensing Unit ×2
Ventilation
Nutone AEN110 50 CFM · Exhaust Fan ×6
QTXEN150 100 CFM · Exhaust Fan ×6
1 job · most recent 03/27/2023
Storm Water/Sanitary
FiledStatusContractorScope
03/27/2023Signed-offPRIME PIPING & HEATING INStorm, Water/Sanitary
1 job · most recent 02/14/2023
General Wiring
FiledStatusContractorScope
02/14/2023CompleteACCURATE ELEC'L CORP.General Wiring
Building Lifecycle
All (74)Filed (6)Permit Issued (4)Signed Off (3)Violation (9)Inspection (8)Objection (14)Special Inspection (30)
11/17/2025
Violation issued (HPD, closed)
I
11/16/2023
Violation issued (HPD, closed)
I
03/31/2023
Special inspection requirement — Maintenance information
sajjad javaid
03/31/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
sajjad javaid
03/31/2023
Special inspection requirement — Fenestration areas
sajjad javaid
03/31/2023
Special inspection requirement — Permanent certificate
sajjad javaid
03/31/2023
Special inspection requirement — Fenestration air leakage
sajjad javaid
03/31/2023
Special inspection requirement — Insulation placement and R values
sajjad javaid
03/31/2023
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
sajjad javaid
03/31/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
sajjad javaid
03/31/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
sajjad javaid
03/31/2023
Special inspection requirement — Energy Code Compliance Inspections
sajjad javaid
03/31/2023
Special inspection requirement — Fire-Resistance Rated Construction
sajjad javaid
03/31/2023
Special inspection requirement — Air barrier - visual inspection
sajjad javaid
03/31/2023
Special inspection requirement — Interior lighting power
sajjad javaid
03/31/2023
Special inspection requirement — Metering
sajjad javaid
03/31/2023
Special inspection requirement — Air barrier — testing
sajjad javaid
03/27/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT MECHANICAL APPLICATION FILED HEREWITH.
X00715941-P2
03/17/2023
Violation issued (HPD, closed)
A
02/02/2023
Signed off — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT MECHANICAL APPLICATION FILED HEREWITH.
X00715941-S1
01/31/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT MECHANICAL APPLICATION FILED HEREWITH.
X00715941-P1
01/31/2023
Signed off — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT MECHANICAL APPLICATION FILED HEREWITH.
X00715941-S3
01/30/2023
Signed off — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT MECHANICAL APPLICATION FILED HEREWITH.
X00715941-S2
01/30/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
sajjad javaid
01/30/2023
Special inspection requirement — Mechanical Systems
sajjad javaid
01/30/2023
Special inspection requirement — Energy Code Compliance Inspections
sajjad javaid
01/30/2023
Special inspection requirement — Final
sajjad javaid
01/30/2023
Special inspection requirement — HVAC-R and service water heating equipment
sajjad javaid
01/30/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
sajjad javaid
01/30/2023
Special inspection requirement — HVAC-R and service water heating system controls
sajjad javaid
01/30/2023
Special inspection requirement — Duct leakage testing, insulation and design
sajjad javaid
01/30/2023
Special inspection requirement — Ventilation and air distribution system
sajjad javaid
01/24/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/06/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
01/04/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
11/29/2022
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
10/21/2022
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
10/21/2022
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
10/21/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/21/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
10/06/2022
Permit issued — Plumbing
X00715941-S2-PL
09/16/2022
Permit issued — Mechanical Systems
X00715941-S1-MS
09/15/2022
Permit issued — General Construction
X00715941-I1-GC
09/01/2022
Permit issued — Sprinklers
X00715941-S3-EW-SP
08/08/2022
Objection raised — Energy
08/08/2022
Objection resolved — Addressed
06/16/2022
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT MECHANICAL APPLICATION FILED HEREWITH.
X00715941-S2
06/12/2022
Objection raised — Fire_Protection
06/12/2022
Objection resolved — Addressed
06/12/2022
Objection raised — Scope
06/12/2022
Objection resolved — Addressed
06/12/2022
Objection raised — Fire_Protection
06/12/2022
Objection resolved — Addressed
06/12/2022
Objection raised — Zoning
06/12/2022
Objection resolved — Addressed
06/12/2022
Objection raised — Mechanical
06/12/2022
Objection resolved — Addressed
06/12/2022
Objection raised — Other
06/12/2022
Objection resolved — Addressed
06/08/2022
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT MECHANICAL APPLICATION FILED HEREWITH.
X00715941-S1
Latest 60 of 74 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
TELLER RESIDENCE LLC203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/03/2022$400K—— → —$98/sf building
05/03/2022$400K—— → —$98/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LEANDRO NILS DICKSON ARCHITECT, LLC203/27/2023
VASILIOS ARTEMIOU PE401/31/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EXPEDITING 4 U603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MJH CONSTRUCTION CORPGeneral Contractor307/08/2026
PRIME PIPING & HEATING INFire Protection107/08/2026
PRIME PIPING & HEATING INPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ESNYC CONSULTING INC4099603/27/2023
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offPRIME PIPING & HEATING IN10/06/2022
DOB NOWMechanical SystemsSigned-offMJH CONSTRUCTION CORP09/16/2022
DOB NOWGeneral ConstructionPermit IssuedMJH CONSTRUCTION CORP09/15/2022
DOB NOWSprinklersSigned-offA M B MECHANICAL INC09/01/2022
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
01/24/2023Pass-Final CND-Occupancy InspectionPassView ↗
01/06/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
01/04/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
11/29/2022Fail-Final CND-Occupancy InspectionFailView ↗
10/21/2022Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
10/21/2022Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
10/21/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/21/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 31
DateRequirementInspectorRole
03/31/2023Maintenance informationsajjad javaidenergy_progress
03/31/2023Fenestration and door U-factor and product ratingssajjad javaidenergy_progress
03/31/2023Fenestration areassajjad javaidenergy_progress
03/31/2023Permanent certificatesajjad javaidenergy_progress
03/31/2023Fenestration air leakagesajjad javaidenergy_progress
03/31/2023Insulation placement and R valuessajjad javaidenergy_progress
03/31/2023Exterior Insulation and Finish Systems (EIFS)sajjad javaidspecial
03/31/2023Fire-Resistant Penetrations and Jointssajjad javaidspecial
03/31/2023Structural Stability – Alterations of existing buildingssajjad javaidspecial
03/31/2023Energy Code Compliance Inspectionssajjad javaidprogress
03/31/2023Fire-Resistance Rated Constructionsajjad javaidprogress
03/31/2023Air barrier - visual inspectionsajjad javaidenergy_progress
03/31/2023Interior lighting powersajjad javaidenergy_progress
03/31/2023Meteringsajjad javaidenergy_progress
03/31/2023Air barrier — testing sajjad javaidenergy_progress
01/30/2023Fire-Resistant Penetrations and Jointssajjad javaidspecial
01/30/2023Mechanical Systemssajjad javaidspecial
01/30/2023Energy Code Compliance Inspectionssajjad javaidprogress
01/30/2023Finalsajjad javaidprogress
01/30/2023HVAC-R and service water heating equipmentsajjad javaidenergy_progress
01/30/2023HVAC-R and service water piping design and insulationsajjad javaidenergy_progress
01/30/2023HVAC-R and service water heating system controlssajjad javaidenergy_progress
01/30/2023Duct leakage testing, insulation and designsajjad javaidenergy_progress
01/30/2023Ventilation and air distribution systemsajjad javaidenergy_progress
05/29/2022Maintenance informationsajjad javaidenergy_progress
Latest 25 of 31.
▾Documents — 54 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/23/2026X00715941-S3Request digital key ↗
08/23/2026X00715941-P2Request digital key ↗
08/23/2026X00715941-P1Request digital key ↗
Showing 3 of 6 on file for this type
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026X00715941-I1Open ↗
▸Seals & Professional Certifications34
▸DOB NOWProgress Inspector Seal & Signature20
08/29/2026X00715941-I1Open ↗
08/29/2026X00715941-I1Open ↗
08/29/2026X00715941-I1Open ↗
Showing 3 of 20 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
09/23/2026X00715941-S2Open ↗
08/29/2026X00715941-I1Open ↗
08/29/2026X00715941-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/13/2026X00715941-P2Open ↗
08/13/2026X00715941-S2Open ↗
08/13/2026X00715941-P1Open ↗
Showing 3 of 6 on file for this type
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/13/2026X00715941-S2Open ↗
08/13/2026X00715941-S3Open ↗
08/13/2026X00715941-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form1
08/13/2026X00715941-S3Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026X00715941-I1Open ↗
▸Other Documents5
▸DOB NOWSite Survey: Initial2
08/13/2026X00715941-P2Open ↗
08/13/2026X00715941-I1Open ↗
▸DOB NOWProperty Ownership Certification2
08/13/2026X00715941-I1Open ↗
08/13/2026X00715941-P2Open ↗
▸DOB NOWFinal Survey1
08/13/2026X00715941-I1Open ↗