HPD09/13/2026§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT PAINT ALL WALLS IN ENTIRE APARTMENT. IN THE ENTIRE APARTMENT LOCATED AT APT 5F, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH
HPD09/13/2026§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 5F, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH
HPD09/13/2026HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5F, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH
HPD09/13/2026HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5F, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH
HPD08/18/2026§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 5th ROOM FROM EAST LOCATED AT APT 5F, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST
HPD08/18/2026§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER AND UPPER SASHES AT WINDOW IN THE BATHROOM LOCATED AT APT 5F, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST
HPD08/18/2026§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 1, WG TO REPLACE = 0, WG TO REPAIR = 0 IN THE ENTIRE APARTMENT LOCATED AT APT 5F, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST
HPD08/18/2026§27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMATION/REQUIRED-SIGNAGE.PAGE
HPD08/09/2026§ 27-2026 ADM CODE RESET, SO AS TO SECURE A PROPER AND TIGHT CONNECTION, THE WATER CLOSET BOWL .. IN THE BATHROOM LOCATED AT APT 5F, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST
HPD08/09/2026§27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMATION/REQUIRED-SIGNAGE.PAGE
HPD08/09/2026§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 5th ROOM FROM EAST LOCATED AT APT 5F, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST
HPD08/09/2026HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5F, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST
HPD08/09/2026§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER SASH 1ST WINDOW FROM WEST AT NORTH WALL IN THE BATHROOM LOCATED AT APT 5F, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST
ECB05/14/2026CLASS 2:FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER PASSENGER ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION,ELEVATOR PHONE INOPERATIVE,REPAIR.ELEVATOR DOES NOT TAKE CALLS TO 2ND FLOOR F$625 due
ECB05/06/2026FAILURE TO CERTIFY CORRECTIONS FOR VIOLATION NUMBER 39084528M, FILE A CERTIFICATE OF CORRECTION$1K due
ECB05/06/2026FAILURE TO CERTIFY CORRECTIONS FOR VIOLATION NUMBER 39085921N, COMPLY WITH COMMISSIONER'S ORDER$2K due
ECB05/06/2026FAILURE TO CERTIFY CORRECTIONS FOR VIOLATION NUMBER 39103394R, FILE A CERTIFICATE OF CORRECTION$625 due
HPD03/28/2025HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3J, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH
HPD03/28/2025HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3J, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH
HPD03/14/2025§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st WINDOW FRAME FROM SOUTH AT WEST WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 5J, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH
HPD03/14/2025§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st DOOR FRAME FROM WEST AT NORTH WALL IN THE BATHROOM LOCATED AT APT 5J, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH
HPD03/14/2025§ 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st RISER FROM SOUTH AT WEST WALL IN THE BATHROOM LOCATED AT APT 5J, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH
HPD03/14/2025§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st WINDOW FRAME FROM NORTH AT EAST WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 5J, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH
HPD03/14/2025§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st DOOR FRAME FROM SOUTH AT WEST WALL IN THE ENTRANCE LOCATED AT APT 5J, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH
HPD03/14/2025§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE BASEBOARD AT SOUTH WALL, CEILING, NORTH WALL IN THE KITCHEN LOCATED AT APT 5J, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH
HPD02/28/2025§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE RADIATOR SHUT OFF VALVE IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT NORTH
HPD11/26/2024§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE 5th ROOM FROM EAST LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH''
DOB05/29/2024FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB10/04/2023FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB10/04/2023FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB10/04/2023FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB10/04/2023FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB10/04/2023FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB10/04/2023FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
HPD08/24/2023§ 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 4H, 4th STORY, 4th APARTMENT FROM NORTH AT EAST
HPD08/24/2023§ 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 4A, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST
HPD08/10/2023§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) NORTH WALL, EAST WALL IN THE 4th ROOM FROM EAST LOCATED AT APT 1F, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST
HPD06/22/2023§ 27-2056.7 ADM CODE: CORRECT FAILURE TO PROVIDE TO THE DEPARTMENT WITHIN 45 DAYS OF DEMAND ALL RECORDS REQUIRED TO BE MAINTAINED BY OWNER PURSUANT TO LOCAL LAW 1 OF 2004 RELATED TO LEAD-BASED PAINT NOTICES, INSPECTIONS AND REMEDIATION/ABATEMENT ACTIVITIES.
HPD06/22/2023§ 27-2056.4 ADM CODE- CORRECT FAILURE TO NOTIFY OCCUPANTS AND/OR TO INVESTIGATE LEAD-BASED PAINT HAZARDS.
DOB05/11/2022FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB03/16/2022FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB11/24/2021FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB12/23/2020FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB02/24/2017VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
DOB06/01/2016FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB06/01/2016FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB06/01/2016FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB06/01/2016FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB06/01/2016FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB06/01/2016FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB06/01/2016FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB10/01/2015VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
DOB05/02/2015FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB03/03/2015VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
DOB03/31/2014VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST
DOB03/08/2013V-DOB VIOLATION - ACTIVE
DOB10/01/2012VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2011 INSPECTION/TEST
DOB08/15/2012VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2010 CAT 1 INSP/TST
DOB08/08/2012FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB01/31/2008V-DOB VIOLATION - ACTIVE
DOB01/31/2008V-DOB VIOLATION - ACTIVE
DOB01/31/2008V-DOB VIOLATION - ACTIVE
ECB11/13/2025FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS. PER BC 1006.1 (2014 CODE). AT TIME OF INSPECTION OBSERVED AT FLOORS 1-6 EMERGENCY LIGHTS THRONothing owed — awaiting certificate of correction
ECB11/13/2025FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED AT EXPOSURE 1(FRONT) 1ST AND 6TH FLOOR MORTAR MISSING AT BRICK JOINTS, EXPO 3(BACK) ROOF CHIMNEY STEP CRACKS AT BRICKS, 2NDNothing owed — awaiting certificate of correction
ECB07/23/2025VIOLATION ISSUED. FAILURE TO COMPLY WITH THE COMMISSIONERS ORDERS TO FILE A CERTIFICATE OF CORRECTION WITH THE DOB FOR VIOLATION#39136122Y, FILE A CERTIFICATE OF CORRECTION; COMPLY WITH COMMISSIONERS ORDERS.Nothing owed — awaiting certificate of correction
ECB04/08/2025FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, THE ONLY DEVICE IN THE BUILDING IS FOUND TO BE OUT OF SERVICE. AS PER 1RCNY 11-02, ANothing owed — awaiting certificate of correction
ECB02/04/2025CLASS 1: CEASE USE: DOOR RESTRICTOR MODIFIED INOPERATIVE REPAIR (CU). RESTORE SERVICE TO 4TH FLOOR. ELDERLY WOMAN IS UNABLE TO LEAVE APARTMENT DUE TO ELEVATOR (CU). CAR DOOR HAS LARGE GAPS ADJUST TO REMOVE (CU)Nothing owed — awaiting certificate of correction
ECB01/22/2025AT EXPOSURE 2 AND 3 FACADE NOT MAINTAINED, VERTICAL CRACKS OVER FIVE FEET IN LENGTH WITH OPENING APPROX HALF INCH WIDE AND STAIR CRACKS WITHBULGING BRICKS BETWEEN SECOND AND THIRD FLOOR WINDOW LOCATIONS, REPAIRNothing owed — awaiting certificate of correction
ECB01/12/2024OBSERVED AT BASEMENT, 2-UNKNOWN MALES LOCATED AT THE SE END OF THE BLDG. SLEEPING ON SEPARATE SOFA/BEDS W. REFRIGERATOR, FOOD ITEMS, CLOTHING, PERSONAL ITEMS, TOILETRIES IN PLACE & SHARING FULL KITCHEN W. ELEC.Nothing owed — awaiting certificate of correction
ECB10/18/2023NO DLM INSTALLED IN CONTROLLER AS MANDATED IN APPENDIX K OF THE 2014 BUILDING CODE; REMEDY INSTALL DLM AND PERFORM TEST WITH NYC DOB; ELEVATOR IS NOT LEVEL WITH LANDING SIL, ELEVATOR STOPPING ABOVE LANDING SILNothing owed — awaiting certificate of correction
ECB08/24/2023AGGRAVATED II CONDITION. RESPONDENT HAS A HISTORY OF FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDERS. RESPONDENT FAILED TO COMPLY WITH THE COMMISSIONER'S ORDERS TO FILE CERTIFICATES OF CORRECTION FOR 11 OPEN ENothing owed — awaiting certificate of correction
ECB06/28/2023ELECTRICAL WORK WITHOUT A PERMIT. NO APPLICATION ON FILE FOR CIRCIUT BREAKERS PANELS IN APT 4G, 5H, 5G, 6C AND HALLWAY FIXTURES EXIT LIGHTS. REMEDY: OBTAIN ALL PERMITSNothing owed — awaiting certificate of correction
ECB06/28/2023NO DOOR LOCK MONITORING INSTALED IN CONTROLLER AS MANDATED IN APPENDIX K OF THE 2014 BUILDING CODES; REMEDY INSTALL DLM FILE AND PERFORM TEST WITH NYC DOB, EMEREGNECY PHON EIN ELEVATOR NOT WORKING,REPAIR; ELEVANothing owed — awaiting certificate of correction
ECB06/21/2023AT TIME OF INSPECTION I OBSERVED THAT VIOLATION NUMBERS 35140534R, 35140538Y, 35140533P AND 35140537M HAVE NOT BEEN CORRECTED. IN RESULT YOU HAVE FAILED TO COMPLY WITH THE COMMISSIONERS ORDERS., FILE A CERTIFICNothing owed — awaiting certificate of correction
ECB06/21/2023FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR VIOLATION#035140535Z/CORRECT ALL VIOLATING CONDITIONS/SUBMIT CERTIFICATE OF CORRECTIONNothing owed — awaiting certificate of correction
ECB05/09/2023W/O A PERMIT. NOTED: AT BSMT SOUTH AT EAST - FULL HEIGHT PARTITION WALLS & SWING DOORS ERECTED TO CREATE 2 BTHRMS AND 6 RMS. WATER & WASTE LINES INSTALLED FOR (2) 3 PC BTHRMS (TOILETS, SINKS, SHOWERS); RESIDENTNothing owed — awaiting certificate of correction
ECB04/24/2023BASEMENT APARTMENTS REOCCUPIED CONTRARY TO VACATE DATED 3/2/16. PREVIOUS VIOLATIONS ISSUED FOR ILLEGAL CONSTRUCTION, PLUMBING AND ELECTRICAL., COMPLY WITH VACATE ORDER; COMPLY WITH VACATENothing owed — awaiting certificate of correction
ECB10/05/202242-M-07 NO DOOR ROCK MONTINTORING INSTALLED IN CONTROLLER AS MANDATED BY 3/10/12 OF APPENDIX K3 OF 2014 NYC BUILDING CODE REMEDY FILE APPLICATION INSTALL DLM & PERFORM & FILE TEST WITH NYCDOBNothing owed — awaiting certificate of correction
ECB08/25/2022CEASE USE VIOLATION ISSUED CAR DOOR RESTRICTOR ALTERED AND MADE NOT TO WORK REMEDY, REPAIR THEN CONTACT ,NYCDOB FOR RESTORE TO SERVICE RE-INSPECTION, .........CLASS 1 VIOLATION ISSUED ,NO DLM INSTALLED IN CONTRNothing owed — awaiting certificate of correction
ECB06/23/2022CLASS 1 VIOLATION ISSUED, NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC, REMEDY; FILE APPLICATION, INSTALL DLM AND PERFORM AND FILE TEST WITH NYCDONothing owed — awaiting certificate of correction
ECB02/07/2022NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS A CONTROLLER FEATURE WHICH ENSURES PASSENGER SAFETY. FILE APPLICATION INSTALL DLM AND PERFORNothing owed — awaiting certificate of correction
ECB12/17/2021CLASS 1 VIOLATION ISSUED NO DLM LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. FILE APPLICATION INSTALL DLM.Nothing owed — awaiting certificate of correction
ECB09/03/2021NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS PER 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. REMEDY; INSTALL DLM AND PERFORM AND FILE TEST WITH NYCDOB. EMERGENCY PHONE INOPERATIVE, REPAIR.Nothing owed — awaiting certificate of correction
ECB09/25/2020NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS PER 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. REMEDY; INSTALL DLM AND, PERFORM AND FILE TEST WITH NYCDOB. TRASH IN PIT. PHONE INSIDE ELEVATOR INOPERATIVE.Nothing owed — awaiting certificate of correction
ECB08/30/2016RESIDENCE ALTERED FOR OCCUPANCY AS A DWELLING FORE MORE THAN THE LEGALLY APPROVED NUMBER OF FAMILIES. DOB RECORDS INDICATE RESIDENCE IS A 56-FAMILY DWELLING (1ST FLR THROUGH 6TH FLR-54 APARTMENTS, BASEMENT, 2Nothing owed — awaiting certificate of correction
ECB04/28/2016OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDING DEPARTMENT RECORDS.NOTED:AT 1ST LEVEL APT'S 1G AND 1D ARE TWO,SEPARATE FUNCTIONING,OCCUPIED DAY CARE CENTERS.BOTH HAVE AT LEAST 5Nothing owed — awaiting certificate of correction
ECB03/02/2016WORK W/O PERMIT AT CELLAR/BASEMENT LEVEL. NOTED: ERECTED FULL HEIGHT PARTITION WALLS CREATING 3 SRO'S (OCCUPIED).INSTALLED DOORS WITH LOCK ING DOOR DEVICES.INSTALLED ELECTRICAL INES,BX,LIGHT FIXTURES,SWITCHESNothing owed — awaiting certificate of correction
ECB03/02/2016FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. FAILURE TO SUP PLY A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED. OBSERVATION HAS BEEN MADE DURING A SAFETY SWEEP IN APTS 1D AND 1G ARE BOTH BEING USEDNothing owed — awaiting certificate of correction
ECB03/02/2016FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:LACK OF A SYSTEMOF AUTOMATIC SPRINKLERS WHERE REQURIED. OBSERVATION HAS BEEN MADE DUR ING A SAFETY SWEEP AT 9:45AM DRYERS IN CELLAR WITH LINT FROM DRYERSNothing owed — awaiting certificate of correction
ECB03/02/2016WORK W/O A PERMIT; WORK NOTED: OBSERVATION HAS BEEN MADE DURING A SAFETY SWEEP IN THE CELLAR A PVC DRAIN HAS BEEN INSTALLED FOR WASH MACHINES.WATER DRAINAGE LINES HAVE BEEN RAN TO SHOWER'S LAVATORIES TOILETS,SINothing owed — awaiting certificate of correction
ECB03/02/2016FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: OBSERVATION HASBEEN MADE DURING SAFETY SWEEP IN APT 4G THE COOKING STOVE HAS NO APPLIANCE VALVE. PHOTO TAKEN. RMDY: REPAIR AND/OR REPLACE.Nothing owed — awaiting certificate of correction
ECB03/02/2016FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:SERVICE-EQUIPMENT BOILER OBSERVATION HAS BEEN MADE DURING A SAFETY SWEEP AT 9:50AM INSIDE BOILER ROOM, BOILER MISSING SECONDARY LOW WATER CUT OFF, AND BOILENothing owed — awaiting certificate of correction
ECB03/02/2016UNAPPROVED UNSAFE UNSUITABLE ELECTRICAL EQUIPMENT DEVICES APPARATUS APPLIANCES MATERIALS OR WIRING IN USE.DEFECTIVE OUTLETS IN APT5C BEDROOM& DEFECTIVE FIXTURES & WIRING THOUGHOUT BASEMENT.REM COMPLY W/ EC CODENothing owed — awaiting certificate of correction
ECB03/02/2016OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDING DEPT RECORDS.NOTED: AT CELLAR/BASEMENT LEVEL ERECTED FULL HT PARTITIONS WALLS CREATED 3 SROS. ALL SROS ARE OCCUPEID WITH BEDS, PERSNothing owed — awaiting certificate of correction
ECB05/08/2012CU16D10 12Q03 15M07 16D-REPAIR LOBBY DOOR BUCK UNSECURE CEASE USE REPAIR IMMEDIATELY ONLY ELEVATOR IN BLDG CALL DOB ELEVATOR DIVISION FOR REINSPNothing owed — awaiting certificate of correction
ECB11/15/2007RESIDENCE ALTERED FOR OCCUPANCY AS A DWELLING FOR MORE THAN THE LEGALLY APPROVED NUMBER OF FAMILIES WORK NOTED: RM IN BASEMENT WITH PARTITI.& 3PC BATHRM & BED.REMEDY:DISCONTINUE ILLEGAL USE OR AMEND COFONothing owed — awaiting certificate of correction
ECB08/30/199920D 9H 28H 14M 22D 74M 33P 50H 50Y 5E 57O 57Z 62K 74M 34D 60M 18B 8V(9CEASE USE CAR DOOR GIB MISSING BACK SLOW SPEED DOOR CALL FOR INSP. 212/312-8732 & CAR DOOR RUBBING (20) SECURE HALL PUSH BUTTON IN LOBBY & WNothing owed — awaiting certificate of correction
ECB05/21/199805J,11B,22D,28H,08P,15J,30O,03O,75U,31R,35P,33P,35Q,31K,14M,13M, 08-PROVIDE ACCESS TO B FLOOR 03-CAR TOP 31-CAR TOPNothing owed — awaiting certificate of correction
ECB02/16/199414M,17I,18R,22D,25M,35O,46K,57O,74O,74M,74L,74M,37R. 17 REPLACE BROKENVISION GLASS WHERE NECESSARY. 18 SECURE A PERMIT AND FILE B N APP. FORNEWLY INSTALLED INTERLOCKS. 25 REPLACE MISSING OPERATOR COVER.Nothing owed — awaiting certificate of correction