| Owner | Filings | Most Recent |
|---|---|---|
| NY CREATIVE DEVELOPERS INC | 29 | 03/22/2026 |
| 966 E 167 LLC | 1 | 03/22/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 01/13/2020 | $275K | — | 964-968 E. 167TH LLC → 966 E 167 LLC | $111/sf building |
| 09/05/2017 | $395K | — | — → — | $160/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| ASHRAF CORP | 5 | 05/16/2024 |
| VASILIOS ARTEMIOU PE | 5 | 08/16/2023 |
| Representative | Filings | Most Recent |
|---|---|---|
| NYC DESIGN FILE | 2 | 03/21/2026 |
| ADVANCED BUILDERS SERVICES | 8 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| MJH CONSTRUCTION CORP | General Contractor | 4 | 03/21/2026 |
| S&R ELECTRICAL & MECHANIC | Electrical | 1 | 03/22/2026 |
| PRIME PIPING & HEATING IN | Fire Protection | 1 | 07/08/2026 |
| PRIME PIPING & HEATING IN | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| ESNYC CONSULTING INC | 4099 | 9 | 05/16/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Sprinklers | Signed-off | A M B MECHANICAL INC | 07/05/2023 |
| DOB NOW | Plumbing | Signed-off | PRIME PIPING & HEATING IN | 01/20/2023 |
| DOB NOW | General Construction | Permit Issued | MJH CONSTRUCTION CORP | 11/03/2022 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 05/16/2024 | Permit Issued | MJH CONSTRUCTION CORP | Associated Ducts and Piping, Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Daikin FTXS12LVJU 431 CFM · Fan Coil Indoor ×14 2MXS18NMVJU 18,000 BTU · Heat Pump Outdoor ×8 CTXS07LVJU 332 CFM · Fan Coil Indoor ×8 RXS12LVJU 14,400 BTU · Heat Pump Outdoor ×8 Qmark MUH0381 300 CFM · Electric Heater ×2 Stelpro AWF1501 160 CFM · Electric Heater ×2 Ventilation Delta Breeze RAD80 50 CFM · Exhaust Fan ×12 Panasonic FV-0510VS1 100 CFM · Exhaust Fan ×12 Ducts & Piping __Junk__ . |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/16/2024 | Signed-off | PRIME PIPING & HEATING IN | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/16/2024 | Signed-off | A M B MECHANICAL INC | Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/06/2023 | Complete | S&R ELECTRICAL & MECHANIC | General Wiring |
| Date | Type | Result | Report |
|---|---|---|---|
| 12/17/2023 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 12/14/2023 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 12/12/2023 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 09/19/2023 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 08/10/2023 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 08/09/2023 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 08/07/2023 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 08/04/2023 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 07/24/2023 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 12/28/2022 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 12/28/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 05/20/2024 | Exterior lighting power | sajjad javaid | energy_progress |
| 05/20/2024 | Metering | sajjad javaid | energy_progress |
| 05/20/2024 | Fenestration and door U-factor and product ratings | sajjad javaid | energy_progress |
| 05/20/2024 | Lighting in dwelling units | sajjad javaid | energy_progress |
| 05/20/2024 | Fire-Resistance Rated Construction | sajjad javaid | progress |
| 05/20/2024 | Energy Code Compliance Inspections | sajjad javaid | progress |
| 05/20/2024 | Structural Stability – Alterations of existing buildings | sajjad javaid | special |
| 05/20/2024 | Fire-Resistant Penetrations and Joints | sajjad javaid | special |
| 03/20/2024 | Exterior lighting power | sajjad javaid | energy_progress |
| 03/20/2024 | Lighting in dwelling units | sajjad javaid | energy_progress |
| 03/20/2024 | Fenestration and door U-factor and product ratings | sajjad javaid | energy_progress |
| 03/20/2024 | Metering | sajjad javaid | energy_progress |
| 03/20/2024 | Fire-Resistance Rated Construction | sajjad javaid | progress |
| 03/20/2024 | Energy Code Compliance Inspections | sajjad javaid | progress |
| 03/20/2024 | Structural Stability – Alterations of existing buildings | sajjad javaid | special |
| 03/20/2024 | Fire-Resistant Penetrations and Joints | sajjad javaid | special |
| 11/30/2023 | Fire-Resistant Penetrations and Joints | sajjad javaid | special |
| 11/30/2023 | Structural Stability – Alterations of existing buildings | sajjad javaid | special |
| 11/30/2023 | Energy Code Compliance Inspections | sajjad javaid | progress |
| 11/30/2023 | Fire-Resistance Rated Construction | sajjad javaid | progress |
| 11/30/2023 | Exterior lighting power | sajjad javaid | energy_progress |
| 11/30/2023 | Metering | sajjad javaid | energy_progress |
| 11/30/2023 | Lighting in dwelling units | sajjad javaid | energy_progress |
| 11/30/2023 | Fenestration and door U-factor and product ratings | sajjad javaid | energy_progress |
| 08/21/2023 | Energy Code Compliance Inspections | sajjad javaid | progress |