← Back
General warehouse
1381 OAK POINT AVENUE
BRONX · BIN 2006865
💬 Discuss this project
1945Year Built
2Stories
E1Building Class
M1-2Zoning
29,906 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
General warehouse · Owner of record: 515 BRYANT REALTY, LLC · 20,000 sf lot · 1.5 FAR built · Flood zone X500
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
3 ROSE REALTY707/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
M.INT'L ENGINEERING PLLC109/14/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CBA CONSULTANTS203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
M. INT'L ENGINEERING PLLCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
M. INT'L ENGINEERING PLLC3129109/14/2022
Building Lifecycle
All (14)Filed (1)Permit Issued (1)Signed Off (1)Violation (2)Objection (6)Special Inspection (3)
10/07/2022
Signed off — Alteration
Replace (3) AC split Units on 2nd floor roof on existing Brackets. No change in use, egress, or occupancy.
X07997646-I1
10/05/2022
Permit issued — Mechanical Systems
X07997646-I1-MS
09/15/2022
Objection raised — Fire_Protection
09/15/2022
Objection resolved — Addressed
09/15/2022
Objection raised — Fire_Protection
09/15/2022
Objection resolved — Addressed
09/15/2022
Objection raised — Inspections
09/15/2022
Objection resolved — Addressed
09/14/2022
Filed — Alteration
Replace (3) AC split Units on 2nd floor roof on existing Brackets. No change in use, egress, or occupancy.
X07997646-I1
09/09/2022
Special inspection requirement — Energy Code Compliance Inspections
NANIK MASSAND
09/01/2022
Special inspection requirement — Mechanical Systems
NANIK MASSAND
09/01/2022
Special inspection requirement — Final
NANIK MASSAND
10/21/2019
Violation issued (FDNY_ORDER, closed)
02/02/2007
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offM. INT'L ENGINEERING PLLC10/05/2022
BISOTISSUEDNATIONAL MICROWAVE09/22/2005
BISOTISSUEDNATIONAL MICROWAVE09/22/2005
BISMHISSUEDNATIONAL MICROWAVE08/31/2005
BISOTISSUEDNATIONAL MICROWAVE08/31/2005
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
09/09/2022Energy Code Compliance InspectionsNANIK MASSANDprogress
09/01/2022Mechanical SystemsNANIK MASSANDspecial
09/01/2022FinalNANIK MASSANDprogress
▾Documents — 5 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/14/2026X07997646-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
08/24/2026X07997646-I1Open ↗
08/24/2026X07997646-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/24/2026X07997646-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/24/2026X07997646-I1Open ↗