DOB07/24/2026FAILURE TO COMPLY W/COMMISSIONER'S ORDER#350801(072026FEU20402KR)DATED 7/20/2026 REQUIRING OWNER TO IMMED:1.PRTLLY DEMO UNSTABLE ROOF,2.INSTL BRACNG/SHORNG AS REQ'D TO STBLZE REMAINING WALL&ROOF,3.INSTLL TEMP ROOF TO MAKE BLDG WEATHRTGHT UNDR FULLTME ONSTE SPRVSN OF NYSPE W/ MEANS&METHDS SBMTTD FOR APPRVL TO FEU.WRK REQ'D TO STRT IMMED UPN APPR
DOB07/20/2026EMERGENCY WORK ORDER.THE ROOF AREA AROUND THE CENTER OR THE REAR WALL PRTLLY CLLPSD,&THE REAR WALL INADEQUATELY BRACD@THE ROOF CLLPSE AREA LOOSE BRCKS@TOP OF THE REAR WALL&FALLEN BRCKS&REAR YRD.IMMEDIATELY COMPLY WITH COMMISSIONER'S ORDER #350601 (072026FEU20402KR) DATED 07/20/2026
DOB07/20/2026EMERGENCY WORK ORDER.THE ROOF AREA PRTLLY CLLPSD,&THE REAR WALL INADEQUATELY BRACD@THE ROOF CLLPSE AREA.LOOSE BRCKS@TOP OF REARWALL& FALLEN BRCKS@REAR YRD OF ADJ PROP@1460 MACOMBS RD OBSERVED.OWNR TO IMMED RTAIN DOB REG CNTRCTR TO INSTLL TGHTBRD CONSTRCTN FNCE@REAR YRD OF 1460 MACOMBS RD,8FT FRM THE REAR WALL@1471
DOB07/20/2026FAILURE TO MAINTAIN BLDG IN A SAFE CONDITION.THE ROOF AREA,ARND THE CENTER OF THE REAR WAL PRTLLY CLLPSD,&THE REAL WALL INADEQUATELY BRACD @THE ROOF CLLPSD AREA LOOSE BRCKS@TOP OF THE REAR WLL.OWNR TO RTAIN NYSPE TO EVAL THE ENT BLDG&RPAIR UNDR PRMT STRT WRK BY 9/7/26&CMPLTE/ SGN OFF BY 10/19/26
DOB07/19/2026BUILDING NO LONGER CODE COMPLIANT DUE TO ROOF BENG OVER LOADED FROM WA TER BACKING UP BY DRAINS AND 20'X 20' SECTIONS OF WOOD FRAMING BETWEEN STEEEL BEAM AND REAR BRICK WALL FALLING IN AND TAKING SECTIN OF REAR BRICK WALL WITH IT RETURN BUILDING TO BE CODE COMPLIANT
DOB07/19/2026BUILDING NOLONGER CODE COMPLIANT DUE TO ROOF BEING OVER LOADED FROM WATER BACKING UP DRAINS AND 20'X20' SECTION OF WOOD FRAMING BETWEEN STEEL BEAM ANDF REAR WALL FALLING IN ....OWNER TO HIRE LICENSED PE TO SUBMIT REPORT TO DOB ERTINSPECTIONS@BUILDINGS.NYC.GOV WITHIN 72 HOURS