HPD09/24/2026§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE CLOSER ARM AT VESTIBULE , 1st STORY
ECB05/25/2026AT THE TIME OF INSPECTION OF A 5-STORY BUILDING, I OBSERVED SIDEWALK SHED IN PLACE, DURING MY INSPECTION I NOTICED SIDEWALK SHED HAS NO BUILDING INFORMATION PANEL. THIS CREATE A HAZARDOUS SITUATION FOR FIRST RE$1K due
DOB11/14/2025VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
DOB11/10/2021FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB10/19/2021FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES.NOTE AT EXP1 AT ROOF LEVEL PARAPET WALL LEANING INWARD WITH MISSING TOP CAPSTONE.SIDEWALK SHED INSTALLED.SHED PERMIT#X00589007 EXPIRED 1/27/2022.REMEDY:MAINTA$6K due
HPD09/17/2021§ 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE THE OBSTRUCTION IN FIREPROOF PASSAGEWAY DEFECTIVE SEALED GATE AT STREET
DOB08/22/2021AT TIME OF INSPECTION OBSERVED SECTION OF BRICK PARAPET WALL APPROXIMATELY 30"-0" SLIGHTLY LEANING INWARD ROOF WITH MORTAR MISSING LOCATIONS.
HPD05/17/2021HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD03/30/2021§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD03/30/2021§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL WALLS IN THE PRIVATE HALLWAY LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD01/21/2021HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, APARTMENT AT SOUTH
HPD01/21/2021§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILINGS IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, APARTMENT AT SOUTH
DOB09/06/2019VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST
DOB01/26/2018VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
DOB01/03/2017VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST
DOB11/14/2016VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST
DOB11/02/2016FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
HPD03/21/2016§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE ON UPPER SASH OF W1 WINDOW IN THE 4th ROOM FROM NORTH LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD03/21/2016§ 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
DOB10/01/2015VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
DOB03/03/2015VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
DOB01/01/2009V-DOB VIOLATION - ACTIVE
DOB03/21/2008V-DOB VIOLATION - ACTIVE
DOB01/03/2008V-DOB VIOLATION - ACTIVE
DOB04/02/2007V-DOB VIOLATION - ACTIVE
DOB01/19/2007V-DOB VIOLATION - ACTIVE
DOB03/21/2003V-DOB VIOLATION - ACTIVE
DOB03/19/2003V-DOB VIOLATION - ACTIVE
DOB02/19/2002V-DOB VIOLATION - ACTIVE
DOB02/10/1997V-DOB VIOLATION - ACTIVE
DOB08/29/1995V-DOB VIOLATION - ACTIVE
DOB06/09/1994V-DOB VIOLATION - ACTIVE
ECB08/22/2021AT TIME OF INSPECTION OBSERVED SECTION OF BRICK PARAPET WALL APPROXIMATELY 30"-0" SLIGHTLY LEANING INWARD ROOF WITH MORTAR MISSING LOCATIONS. PROVIDE ENGINEER'S REPORT ON STRUCTURAL STABILITY OF PARAPET., MAINTNothing owed — awaiting certificate of correction
ECB08/01/201605M07,59M07,56Y02,56Y13,77K10,71L10,17H11,40D06.DOOR RESTRICTOR MISSING PROVIDE,BRAKE MAINTENANCE TAG MISSING PROVIDE,HOIST MACHINE OIL LEAKCLEAN,HOIST MACHINE OIL LEAK SEAL,UNDERSIDE PLATFORM RUSTED REPAIR,PITNothing owed — awaiting certificate of correction
ECB06/15/200997X10.97X10 1RCNY 11-02 ONLY ELEVATOR IN BLDG OUT OF SERVICE RESTOR TO SERVICE (HAZARDOUS) 40P16 PROVIDE ACCESS TO M/R SO THAT AFULL INSPECTION CAN BE DONE BY THIS DEPTNothing owed — awaiting certificate of correction
ECB05/17/200583X10/85B07. 83-X-10-RETURN DEVICE TO SERVICE TO BE FULLY INSPECTED BYA D.O.B. ELEVATOR INSPECTOR. 85-B-07-TAG IS STAMPED 07-PLEASE CLARIFY DATE 07-PERFORM THE 5 YR. TESTNothing owed — awaiting certificate of correction
ECB08/03/2000FAILURE TO FILE A REPORT OF COMPLIANCE WITH LOCAL LAW 16/84 CERTIFYING TO THE INSTALLATION OF REQUIRED FIRE PROTECTION SYSTEMS.REMEDY:FILE REPORT.Nothing owed — awaiting certificate of correction
ECB08/03/2000FAILURE TO PROVIDE ELEVATOR LANDING SIGN FOR ELEVATOR BANK ON FLOOR 2 TO 6.FAILURE TO PROVIDE 3-INCH HIGH ALPHABETIC LETTER OF IDENTIFICATION FOR ELEVATOR BANK AND FOR OPEN STAIR ON FLOOR 1 TO 6E.FAILURE TO PRONothing owed — awaiting certificate of correction
ECB04/08/199814M12,11Q3,35P17,62M7. 62-TOE GUARD.Nothing owed — awaiting certificate of correction
ECB07/14/1997INSUFFICIENT SOURCE OF WATER SUPPLY FOR SPRINKLER SYSTEM; IN THAT THE AMOUNT OF SPRINKLER HEADS INSTALLED (31) EXCEEDS THE MAXIMUM ALLOWABLE NUMBER OF HEADS (10) INSTALLED ON THE 2" WATER SERVICE. REMEDY: PROVINothing owed — awaiting certificate of correction