DOB05/19/2026V-DOB VIOLATION - ACTIVE
DOB05/19/2026REMEDY: SEAL BUILDING ENTRY DOORS AT EXPOSURE, CELLAR AT REAR OF BUILDING EXPOSURE 3 AND 4. SECURE AND LOCK CONSTRUCTION FENCE. MAKE SITE SAFE TO PUBLIC
ECB04/27/2026FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTR OPERATIONS. NOTED: AT TIME OF INSPECTION AT JOBSITE UNDER EXPIRED PERMIT # X01257794-S1-GC-CX: CONSTR FENCE DOOR WAS OBSERVED UNSECURED, PERMITTI$10K due
DOB11/14/2025VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
DOB10/30/2025FAILURE TO MAINTAIN.DUE TO A 2-ALARM FIRE THAT OCCURRED ON 7/14/25, REAR EXTS@EXP3/4 CRNR&2/3 CRNR HAVE A PRTLLY CLLPSD ROOF,2ND&1ST FLRS INTO BSMNT,LEAVNG PERIMTR WALLS INPROPERLY BRACD STRCTRRLY CM.COMPLY WITH COMMISSIONER'S ORDER:DOB VIOLATION #071625FEU20602AK (CONTROL # 341581) IMMEDIATELY
DOB08/28/2025ADDITIONAL INFORMATION.DUE TO A FIRE THAT OCCURRD ON 7/14/25,REAR EXTS @EXP3/4 CRNR HAVE A PRTLLY CLLPSD ROOF,2ND,&1STFL INTO BSMNT,LEAVNG PERIMETR WALLS IMPROPERLY BRACD&STRCTRLLY CMPRMSD.COMPLY W/ COMMISSIONER'S ORDER-DOB VIO#071625FEU20601AK CONTROL #341580 IMMEDIATELY
DOB07/16/2025ADDITIONAL INFORMATION.DUE TO A FIRE THAT OCCURRED ON 7/14/25,REAR EXTS@EXP3/4 CRNR HAVE A PRTLLY CLLPSD ROOF,2ND,&1STFL INTO BSMNT, LEAVNG PERIMETR WALLS IMPROPERLY BRACD&STRCTRLLY CMPRMSD.OWNR TO ENGAGE NYSPE W/O DISCIPLINARY ACTION TO EVAL THE ENT BLDG STRCTRE(INCL BELL TOWER)&PREPARE A SGND&SEALD RPT W/PHT
DOB07/16/2025FAILURE TO MAINTAIN.DUE TO A 2-ALARM FIRE THAT OCCURRED ON 7/14/25, REAR EXTS@EXP 3/4 CRNR&2/3 CRNR HAVE A PRTLLY CLLPSD ROOF,2ND&1ST FLRS INTO BSMNT,LEAVNG PERIMTR WALLS IMPROPERLY BRACD STRCTRLLY CMPRMSD OWNR TO ENGAGE NYSPE&ENDRSD CNTRCTR TO EVAL THE ENT BLDG&RPR UNDR PMT, FILE FO RPAIRS BY 10/16/25.SGN OFF BY 2/16/26
DOB07/15/2025REMEDY: INSTALL CONSTRUCTION FENCE AROUND THE BLDG TO ENCLOSE THE POTE NTIAL COLLAPSE ZONE AND SAFEGUARD THE PUBLIC AND PROPERTY
DOB07/15/2025EMERGENCY WORK.DUE TO A 2ALARM FIRE THAT OCCURRD ON 7/14/25,REAR EXT@ EXP4/3 CRNR HAS PRTLLY CLLPSD ROOF,2ND&1ST FLS INTO BSMNT LVL,LEAVNG PERIMTR WALLS IMPROPERLY BRACD&STRCTRLLY CMPRMSD.REAR EXT@EXP2.OWNR TO IIMMED HIRE GC ENDRSD FOR DEMO&NYSPE TO INSTALL TEMP EXTERIOR BRACE PERIMTR WALLS@BOTH REAR EXTENSIONS
DOB07/15/2025FAILURE TO MAINTAIN.DUE TO A 2-ALARM FIRE THAT OCCURRED ON 7/14/25, REAR EXTS@EXP3/4 CRNR&2/3 CRNR HAVE A PRTLLY CLLPSD ROOF,2ND&1ST FLRS INTO BSMNT,LEAVNG PERIMTR WALLS IMPROPERLY BRACD STRCTRLLY CMPRMSD OWNR TO ENGAGE NYSPE&ENDRSD CNTRCTR TO EVAL THE ENT BLDG&RPR UNDR PRMT.FILE FOR RPAIRS BY 10/16/25.SGN OFF RPAIRS BY 2/16/26
DOB07/14/2025DOB SUMMONS ISSUED FOR STRUCTURE RENDERED BON COMPLIANT DUE TO EXTENSIVE FIRE, SMOKE AND WATER DAMAGE THROUGHOUT ALONG WITH PARTIAL ROOF COLLAPSE AT REAR OF STRUCTURE
DOB09/23/2024VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
DOB11/08/2019VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
DOB04/06/2018VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
DOB02/24/2017VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
DOB03/01/2013VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT
DOB12/13/2011VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
DOB12/31/2009V-DOB VIOLATION - ACTIVE
DOB01/01/2009V-DOB VIOLATION - ACTIVE
DOB01/03/2008V-DOB VIOLATION - ACTIVE
DOB01/19/2007V-DOB VIOLATION - ACTIVE
DOB01/06/2006V-DOB VIOLATION - ACTIVE
DOB01/31/2005V-DOB VIOLATION - ACTIVE
DOB02/13/2004V-DOB VIOLATION - ACTIVE
DOB03/19/2003V-DOB VIOLATION - ACTIVE
DOB03/26/2002V-DOB VIOLATION - ACTIVE
DOB02/27/2001V-DOB VIOLATION - ACTIVE
DOB02/07/2000V-DOB VIOLATION - ACTIVE
DOB05/04/1998V-DOB VIOLATION - ACTIVE
DOB06/09/1994V-DOB VIOLATION - ACTIVE
DOB05/17/1993V-DOB VIOLATION - ACTIVE
ECB04/27/2026TEMPORARY CONSTRUCTION EQUIPMENT ON SITE - EXPIRED PERMIT. NOTED: AT TIME OF INSPECTION - PERIMETER CONSTRUCTION FENCE OBSERVED ERECTED UNDER PERMIT # X01257794-I1-FN. PERMIT EXPIRED 03/31/2026., RENEW PERMITHearing held — result not yet published$625 proposed
ECB10/06/201750A:AS PER CLASS 2(B265)28.303.7:FAILURE TO FILE A COMPLETE BOILER INSPECTION REPORT AS PER DOB RECORDS.SUBMIT A COMPLETE BOILER SAFETY INITIAL REPORT.Nothing owed — awaiting certificate of correction
ECB04/01/2010FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES: BANISTER AT FRONT SIDE OF THE BUILDING APPROX 6FT HIGH HAVE SEVERE VERTICAL CRACKS,OUT OF PLUMB & LEANING OUTWARD ONTO PUBLIC SIDEWALK. BANISTER SIZE: 6FTNothing owed — awaiting certificate of correction