← Back
Two stories - detached, small or mid-size
21 WEST 192 STREET
BRONX · BIN 2014473
💬 Discuss this project
1928Year Built
2.5Stories
A1Building Class
R6Zoning
3,537 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · Owner of record: SG 21 W 192ND ST LLC · 3,200 sf lot · 1.11 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalCivil
Roof2p · 1 filing · 5 docs
Penthouse3p · 1 filing · 5 docs
Floor 42p · 1 filing · 5 docs
Floor 3
Floor 21p · 1 filing · 5 docs
Floor 11p · 1 filing · 5 docs
Cellar3p · 1 filing · 5 docs
1 job · most recent 08/05/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/05/2026——Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Gree LIVV12HP230V1AO 12,000 BTU · Condensing Unit ×9
GMV-24WL/C-T(U) 24,000 BTU · Vrf Outdoor ×6
GMV-36WL/A-T(U) 37,500 BTU · Vrf Outdoor ×3
GMV-28WL/C-T(U) 28,000 BTU · Vrf Outdoor ×1
Ventilation
Greenheck G-070-VG 244 CFM · Exhaust Fan ×7
G-080-VG 404 CFM · Exhaust Fan ×2
Mitsubishi Electric LGH-F300RVX-E 300 CFM · Erv ×1
1 job · most recent 08/05/2026
Sprinkler System
FiledStatusContractorScope
08/05/2026——Sprinkler System
1 job · most recent 08/05/2026
Steel Concrete
FiledStatusContractorScope
08/05/2026——Steel, Concrete
1 job · most recent 12/17/2025
Fence
FiledStatusContractorScope
12/17/2025Permit IssuedLLNY GROUP,LLCFence
Building Lifecycle
All (41)Filed (7)Permit Issued (3)Objection (1)Special Inspection (30)
08/18/2026
Objection raised — Other
08/05/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
INSTALL NEW HVAC SYSTEM FOR THE BUILDING SUBSEQUENT WITH DOB NOW #X01350085, NO CHANGE IN USE, EGRESS AND OCCUPANCY.
X01350085-S4
08/05/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
INSTALL NEW HVAC SYSTEM FOR THE BUILDING SUBSEQUENT WITH DOB NOW #X01350085, NO CHANGE IN USE, EGRESS AND OCCUPANCY.
X01350085-S1
08/05/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
INSTALL NEW HVAC SYSTEM FOR THE BUILDING SUBSEQUENT WITH DOB NOW #X01350085, NO CHANGE IN USE, EGRESS AND OCCUPANCY.
X01350085-S3
08/05/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
INSTALL NEW HVAC SYSTEM FOR THE BUILDING SUBSEQUENT WITH DOB NOW #X01350085, NO CHANGE IN USE, EGRESS AND OCCUPANCY.
X01350085-S5
08/05/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
INSTALL NEW HVAC SYSTEM FOR THE BUILDING SUBSEQUENT WITH DOB NOW #X01350085, NO CHANGE IN USE, EGRESS AND OCCUPANCY.
X01350085-S2
08/05/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
08/05/2026
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
08/05/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
08/05/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
08/05/2026
Special inspection requirement — Subgrade Inspections
08/04/2026
Special inspection requirement — Post-installed Anchors
08/04/2026
Special inspection requirement — Concrete - Cast-In-Place
08/04/2026
Special inspection requirement — Structural Steel - Details
08/04/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
08/04/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
08/04/2026
Special inspection requirement — Structural Steel - Welding
08/04/2026
Special inspection requirement — Structural Steel - High Strength Bolting
07/27/2026
Special inspection requirement — Final
04/01/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
04/01/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
04/01/2026
Special inspection requirement — Energy Code Compliance Inspections
04/01/2026
Special inspection requirement — Fire-Resistance Rated Construction
04/01/2026
Special inspection requirement — HVAC-R and service water heating system controls
04/01/2026
Special inspection requirement — Maintenance information
04/01/2026
Special inspection requirement — HVAC-R and service water heating equipment
04/01/2026
Special inspection requirement — Shutoff dampers
03/31/2026
Special inspection requirement — Mechanical Systems
03/31/2026
Special inspection requirement — Final
03/09/2026
Permit issued — Construction Fence
X01333929-I1-FN
02/04/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
INSTALL NEW HVAC SYSTEM FOR THE BUILDING SUBSEQUENT WITH DOB NOW #X01350085, NO CHANGE IN USE, EGRESS AND OCCUPANCY.
X01350085-I1
02/04/2026
Special inspection requirement — Fire-Resistance Rated Construction
02/04/2026
Special inspection requirement — Energy Code Compliance Inspections
02/04/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
02/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
02/04/2026
Special inspection requirement — Concrete - Cast-In-Place
02/04/2026
Special inspection requirement — Permanent certificate
02/04/2026
Special inspection requirement — Air barrier - visual inspection
01/22/2026
Permit issued — Construction Fence
X01333929-I1-FN
01/16/2026
Permit issued — Construction Fence
X01333929-I1-FN
12/17/2025
Filed — Alteration
PROPOSED TEMPORARY CONSTRUCTION FENCE OUTSIDE THE PROPERTY LINE BUT WITHIN 3 FEET OF THE PROPERTY LINE.
X01333929-I1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BROOKLYN GRID809/13/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/15/2025$995K—— → —$281/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ARC CONSULTING ENGINEERS708/05/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NEXT STEP BUILDING SOLUTIONS203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
LLNY GROUP,LLCGeneral Contractor504/09/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedLLNY GROUP,LLC03/09/2026
DOB NOWConstruction FencePermit IssuedLLNY GROUP,LLC01/22/2026
DOB NOWConstruction FencePermit IssuedLLNY GROUP,LLC01/16/2026
▾Special Inspection Requirements (DOB NOW) — 42
DateRequirementInspectorRole
08/05/2026Structural Stability – Alterations of existing buildings—special
08/05/2026Subsurface Conditions – Fill Placement & In-Place Density—special
08/05/2026Excavations - Sheeting, Shoring, and Bracing—special
08/05/2026Subsurface Investigations (Borings/Test Pits)—special
08/05/2026Subgrade Inspections—special
08/04/2026Post-installed Anchors—special
08/04/2026Concrete - Cast-In-Place—special
08/04/2026Structural Steel - Details—special
08/04/2026Structural Stability – Alterations of existing buildings—special
08/04/2026Structural Stability – Alterations of existing buildings—special
08/04/2026Structural Steel - Welding—special
08/04/2026Structural Steel - High Strength Bolting—special
07/27/2026Final—progress
04/01/2026HVAC-R and service water piping design and insulation—energy_progress
04/01/2026Fire-Resistant Penetrations and Joints—special
04/01/2026Energy Code Compliance Inspections—progress
04/01/2026Fire-Resistance Rated Construction—progress
04/01/2026HVAC-R and service water heating system controls—energy_progress
04/01/2026Maintenance information—energy_progress
04/01/2026HVAC-R and service water heating equipment—energy_progress
04/01/2026Shutoff dampers—energy_progress
03/31/2026Mechanical Systems—special
03/31/2026Final—progress
02/04/2026Fire-Resistance Rated Construction—progress
02/04/2026Energy Code Compliance Inspections—progress
Latest 25 of 42.
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/17/2026X01333929-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026X01350085-I1Open ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/17/2026X01333929-I1Open ↗
08/13/2026X01350085-I1Open ↗
▸Other Documents3
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026X01350085-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/13/2026X01350085-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026X01350085-I1Open ↗