← Back
One story retail building
1623 EAST 172 STREET
BRONX · BIN 2027528
💬 Discuss this project
1930Year Built
1Stories
K1Building Class
R6Zoning
5,000 sfGross Floor Area
4Units
21 Open Violations 19 unresolved · 2 paperwork only ▸
One story retail building · Owner of record: 1623 REALTY INC. · 5,000 sf lot · 1 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Permit Issued — active, not yet Signed-off
Roof5p · 1 filing · 10 docs
Floor 12p · 1 filing · 3 docs
CellarUnder Construction17p · 2 filings · 13 docs
1 job · most recent 04/11/2025
Associated Ducts and Piping Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
04/11/2025Permit IssuedMAXIMO BLDG.SERVICES CORPAssociated Ducts and Piping, Ventilation Systems
Ventilation
Captiveaire MODEL # NCA18HFA 2,500 CFM · Kitchen Exhaust ×3
Pennbarry FX13BHFT 3,000 CFM · Exhaust Fan ×1
MU4012 2,700 CFM · Makeup Air ×1
Ducts & Piping
N/A N/A Ductwork ×1
1 job · most recent 06/03/2022
Gas Water/Sanitary
FiledStatusContractorScope
06/03/2022Permit IssuedCJ HEATING & MECHANICAL CGas, Water/Sanitary
1 job · most recent 03/17/2022
General Wiring
FiledStatusContractorScope
03/17/2022Permit IssuedDELTA ELEC'L CONTR'G CORPGeneral Wiring
Building Lifecycle
All (53)Filed (5)Permit Issued (4)Violation (22)Inspection (6)Special Inspection (16)
03/30/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
03/25/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
02/25/2026
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
02/18/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
01/14/2026
Permit issued — Plumbing
X00717716-I1-PL
04/11/2025
Filed — Alteration
DIRECT REPLACEMENT OF EXISTING/OLD EXHAUST HOOD, EXHAUST DUCT AND EXHAUST FAN WITH NEW AT EXISTING DELI/GROCERY STORE. NO OTHER WORK PROPOSED. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
X00717708-S1
10/03/2024
Special inspection requirement — Final
10/03/2024
Special inspection requirement — Mechanical Systems
06/24/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/14/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/06/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Withdrawn
06/06/2022
Special inspection requirement — HVAC-R and service water heating equipment
Withdrawn
06/06/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Withdrawn
06/03/2022
Filed — Alteration
Application filed for plumbing modifications/additions as per plans filed herewith. No change in use, egress or occupancy.
X00717716-P1
06/01/2022
Special inspection requirement — HVAC-R and service water heating equipment
Vincent Gentile
06/01/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Vincent Gentile
06/01/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Vincent Gentile
05/20/2022
Permit issued — Mechanical Systems
X00717708-I1-MS
05/12/2022
Filed — Alteration
DIRECT REPLACEMENT OF EXISTING/OLD EXHAUST HOOD, EXHAUST DUCT AND EXHAUST FAN WITH NEW AT EXISTING DELI/GROCERY STORE. NO OTHER WORK PROPOSED. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
X00717708-I1
05/12/2022
Permit issued — Plumbing
X00717716-I1-PL
05/11/2022
Filed — Alteration
Application filed for plumbing modifications/additions as per plans filed herewith. No change in use, egress or occupancy.
X00717716-I1
05/11/2022
Special inspection requirement — Shutoff dampers
Vincent Gentile
04/25/2022
Special inspection requirement — Energy Code Compliance Inspections
Vincent Gentile
04/25/2022
Special inspection requirement — Duct leakage testing, insulation and design
Vincent Gentile
04/25/2022
Special inspection requirement — Maintenance information
Vincent Gentile
04/25/2022
Special inspection requirement — HVAC-R and service water heating equipment
Vincent Gentile
04/25/2022
Special inspection requirement — HVAC-R and service water heating system controls
Vincent Gentile
04/12/2022
Special inspection requirement — Final
RICHARD LEMANSKY
04/12/2022
Special inspection requirement — Mechanical Systems
Vincent Gentile
03/07/2022
Permit issued — Structural
X00681828-I1-GC-CX
02/27/2022
Filed — Alteration
X00681828-I1
12/13/2011
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
12/31/2009
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/01/2009
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
05/12/2008
Violation issued (ECB, closed)
Construction
01/03/2008
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/02/2007
Violation issued (ECB, open)
Construction
01/19/2007
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/06/2006
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/31/2005
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/13/2004
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/19/2003
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/26/2002
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/24/2002
Violation issued (ECB, open)
Construction
02/27/2001
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/07/2000
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/16/1999
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
05/04/1998
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/16/1997
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/10/1997
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
08/29/1995
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/09/1994
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
05/17/1993
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
REALTY103/22/2026
1623 REALTY INC.303/22/2026
CCA FOOD CORP103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KDV DESIGNS ARCHITECTS LLC104/11/2025
RHL ENGINEERING, LLC306/03/2022
JIMENEZ BUILDING CONSULTING LLC102/27/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
TBC & ASSOC.203/21/2026
EA DESIGN GROUP803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MAXIMO BLDG.SERVICES CORPGeneral Contractor407/08/2026
JOE MIDDLETONElectrical203/21/2026
CJ HEATING & MECHANICAL CPlumbing207/08/2026
DELTA ELEC'L CONTR'G CORPElectrical103/22/2026
G.M.A. PLUMBING & HEATINGPlumbing103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
RHL ENGINEERING, LLC712306/03/2022
RICHMOND TESTING LAB263102/27/2022
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedCJ HEATING & MECHANICAL C01/14/2026
DOB NOWMechanical SystemsPermit IssuedMAXIMO BLDG.SERVICES CORP05/20/2022
DOB NOWPlumbingPermit IssuedCJ HEATING & MECHANICAL C05/12/2022
DOB NOWStructuralPermit IssuedMAXIMO BLDG.SERVICES CORP03/07/2022
BISFPISSUEDMASTER FIRE SYSTEMS, INC05/27/2009
BISOTISSUEDNEW YORK SIGN CONTRACTORS03/18/2009
BISOTISSUEDN/A03/05/1997
BISPLISSUEDMAGOR PLUMBING & HEATING05/28/1996
BIS—ISSUEDSUPER LAUNDRY EQUIPMENT CORP.04/02/1990
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
03/30/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
03/25/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
02/25/2026Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
02/18/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
06/24/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/14/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 16
DateRequirementInspectorRole
10/03/2024Final—progress
10/03/2024Mechanical Systems—special
06/06/2022Fire-Resistant Penetrations and JointsWithdrawnspecial
06/06/2022HVAC-R and service water heating equipmentWithdrawnenergy_progress
06/06/2022HVAC-R and service water piping design and insulationWithdrawnenergy_progress
06/01/2022HVAC-R and service water heating equipmentVincent Gentileenergy_progress
06/01/2022HVAC-R and service water piping design and insulationVincent Gentileenergy_progress
06/01/2022Fire-Resistant Penetrations and JointsVincent Gentilespecial
05/11/2022Shutoff dampersVincent Gentileenergy_progress
04/25/2022Energy Code Compliance InspectionsVincent Gentileprogress
04/25/2022Duct leakage testing, insulation and designVincent Gentileenergy_progress
04/25/2022Maintenance informationVincent Gentileenergy_progress
04/25/2022HVAC-R and service water heating equipmentVincent Gentileenergy_progress
04/25/2022HVAC-R and service water heating system controlsVincent Gentileenergy_progress
04/12/2022FinalRICHARD LEMANSKYprogress
04/12/2022Mechanical SystemsVincent Gentilespecial
▾Documents — 40 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/24/2026X00681828-I1Request digital key ↗
08/24/2026X00717716-I1Request digital key ↗
08/24/2026X00717716-P1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits5
▸BISWORK PERMIT APPLICATION3
05/27/2009220006035Open ↗
03/18/2009210008597Open ↗
12/17/2008210008597Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION2
05/15/2009220006035Open ↗
12/15/2008210008597Open ↗
▸Seals & Professional Certifications17
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/24/2026X00681828-I1Open ↗
08/24/2026X00717716-P1Open ↗
08/24/2026X00717716-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
09/01/2026X00717708-I1Open ↗
09/01/2026X00717708-I1Open ↗
09/01/2026X00717708-I1Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
05/15/2009220006035Open ↗
12/15/2008210008597Open ↗
03/10/2008210008597Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/01/2026X00717708-I1Open ↗
09/01/2026X00717716-P1Open ↗
08/24/2026X00717716-I1Open ↗
▸Trade Schedules & Equipment2
▸BISSCHEDULE B - PLUMBING2
05/15/2009220006035Open ↗
12/15/2008210008597Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/24/2026X00681828-I1Open ↗
08/24/2026X00717716-P1Open ↗
08/24/2026X00717716-I1Open ↗
Showing 3 of 5 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
05/15/2009220006035Open ↗
12/16/2008210008597Open ↗
▸Approvals, Objections & Sign-offs2
▸BISADMINISTRATIVE OBJECTIONS2
05/19/2009220006035Open ↗
12/06/2007210008597Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
05/15/2009220006035Open ↗
12/15/2008210008597Open ↗