← Back
Three families
1424 GLOVER STREET
BRONX · BIN 2041572
💬 Discuss this project
1899Year Built
2Stories
C0Building Class
R5AZoning
3,316 sfGross Floor Area
3Units
Rent Stabilized0 Open Violations
Three families · 3,125 sf lot · 1.06 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
DOYUN KIM; RA101/05/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KC EXPEDITING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
WMS ELECTRICAL CONTNG LTDElectrical103/22/2026
SOLAR PRO INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DOYUN KIM; RA7415101/05/2024
Building Lifecycle
All (23)Filed (1)Permit Issued (1)Signed Off (1)Violation (5)Objection (10)Special Inspection (5)
03/14/2024
Signed off — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY, OR EGRESS. NO CHANGE IN BULK
X00985959-I1
02/07/2024
Permit issued — Solar
X00985959-I1-SL
01/29/2024
Objection resolved — Addressed
01/23/2024
Objection resolved — Addressed
01/22/2024
Objection resolved — Addressed
01/22/2024
Objection resolved — Addressed
01/22/2024
Objection resolved — Addressed
01/11/2024
Objection raised — Other
01/11/2024
Objection raised — Structural
01/11/2024
Objection raised — Other
01/11/2024
Objection raised — Other
01/11/2024
Objection raised — Admin
01/05/2024
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY, OR EGRESS. NO CHANGE IN BULK
X00985959-I1
01/04/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
DOYUN KIM
01/04/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
DOYUN KIM
01/04/2024
Special inspection requirement — Energy Code Compliance Inspections
DOYUN KIM
01/04/2024
Special inspection requirement — Final
JEFFREY BELL
01/04/2024
Special inspection requirement — Air barrier - visual inspection
DOYUN KIM
02/17/2022
Violation issued (HPD, closed)
A
04/02/2021
Violation issued (HPD, closed)
A
04/02/2021
Violation issued (HPD, closed)
I
11/13/2017
Violation issued (HPD, closed)
I
10/28/2016
Violation issued (HPD, closed)
I
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSOLAR PRO INC02/07/2024
3 projects · most recent 03/04/2024
General Wiring
FiledStatusContractorScope
03/04/2024CompleteVILLAGE ELECTL CONTRS INC—
06/06/2019CompleteWMS ELECTRICAL CONTNG LTDGeneral Wiring
01/17/2018CompleteWMS ELECTRICAL CONTNG LTDGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
01/04/2024Fire-Resistant Penetrations and JointsDOYUN KIMspecial
01/04/2024Structural Stability – Alterations of existing buildingsDOYUN KIMspecial
01/04/2024Energy Code Compliance InspectionsDOYUN KIMprogress
01/04/2024FinalJEFFREY BELLprogress
01/04/2024Air barrier - visual inspectionDOYUN KIMenergy_progress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/21/2026X00985959-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
09/01/2026X00985959-I1Open ↗
09/01/2026X00985959-I1Open ↗
09/01/2026X00985959-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026X00985959-I1Open ↗
09/01/2026X00985959-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/21/2026X00985959-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/21/2026X00985959-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026X00985959-I1Open ↗