← Back
Two family frame
1710 VAN BUREN STREET
BRONX · BIN 2042600
💬 Discuss this project
1905Year Built
2Stories
B2Building Class
R5Zoning
3,690 sfGross Floor Area
2Units
4 Open Violations 2 unresolved · 2 paperwork only ▸
Two family frame · 2,500 sf lot · 1.48 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Cellar1p · 1 filing · 11 docs
Basement5p · 1 filing · 11 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
CITIBANK, NA/TMUSTEC103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
RICHARD MONTANA, ARCHITECT512/11/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
A GUAMAN CONSTRUCTION CORGeneral Contractor707/08/2026
JADA PLUMBING & HTG LLCPlumbing507/08/2026
Building Lifecycle
All (23)Filed (5)Permit Issued (5)Signed Off (2)Violation (5)Inspection (5)Special Inspection (1)
04/20/2026
Signed off — Alteration
X08015285-I1
04/15/2026
Signed off — Alteration
X08015285-S1
03/24/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
01/09/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/19/2025
Permit issued — Plumbing
X08015285-S1-PL
12/11/2024
Filed — Alteration
X08015285-P3
08/15/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/21/2024
Violation issued (ECB, closed)
Unknown
09/25/2023
Permit issued — General Construction
X08015285-I1-GC
09/20/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/20/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
07/11/2023
Permit issued — Plumbing
X08015285-S1-PL
03/31/2023
Permit issued — General Construction
X08015285-I1-GC
03/29/2023
Filed — Alteration
X08015285-P2
02/25/2023
Filed — Alteration
X08015285-P1
02/24/2023
Permit issued — General Construction
X08015285-I1-GC
11/08/2022
Filed — Alteration
X08015285-S1
10/31/2022
Filed — Alteration
X08015285-I1
10/31/2022
Special inspection requirement — Final
Richard Montana
06/28/2022
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/28/2022
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/19/2002
Violation issued (ECB, open)
Construction
01/25/2002
Violation issued (ECB, open)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offJADA PLUMBING & HTG LLC09/19/2025
DOB NOWGeneral ConstructionSigned-offA GUAMAN CONSTRUCTION COR09/25/2023
DOB NOWPlumbingSigned-offJADA PLUMBING & HTG LLC07/11/2023
DOB NOWGeneral ConstructionSigned-offA GUAMAN CONSTRUCTION COR03/31/2023
DOB NOWGeneral ConstructionSigned-offA GUAMAN CONSTRUCTION COR02/24/2023
BISOTISSUEDCENTURION SOLAR ENERGY10/18/2017
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
03/24/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/09/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/15/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
09/20/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/20/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 1
DateRequirementInspectorRole
10/31/2022FinalRichard Montanaprogress
▾Documents — 28 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/23/2026X08015285-P3Request digital key ↗
08/23/2026X08015285-P2Request digital key ↗
08/23/2026X08015285-S1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
10/17/2017240201571Open ↗
▸BISWORK PERMIT APPLICATION1
10/18/2017240201571Open ↗
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/23/2026X08015285-P2Open ↗
08/23/2026X08015285-P1Open ↗
08/23/2026X08015285-P3Open ↗
Showing 3 of 5 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
10/17/2017240201571Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/30/2026X08015285-I1Open ↗
▸Safety & Tenant Protection1
▸BISTENANT PROTECTION PLAN AND NOTES1
10/17/2017240201571Open ↗
▸Environmental & Asbestos1
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
10/17/2017240201571Open ↗
▸Energy Compliance5
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
01/30/2018240201571Open ↗
10/17/2017240201571Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
10/17/2017240201571Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (FINAL)1
02/06/2018240201571Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
01/30/2018240201571Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
01/30/2018240201571Open ↗
10/17/2017240201571Open ↗
▸Approvals, Objections & Sign-offs2
▸BISUtility Company PV System Interconnection Acknowledgement Letter1
01/30/2018240201571Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
01/30/2018240201571Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
01/30/2018240201571Open ↗
10/17/2017240201571Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
10/17/2017240201571Open ↗