ECB02/20/2024FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER - INTERIOR COLLAPSE FROM THE ROOF LEVEL TO THE CELLAR LEVEL. EXTERIOR WALL SHOWS OUTWARD DEFLECTION. PREMISES HAD BEEN SEALED WITH PYLWOOD AND PADLOCKS FO$12K due
DOB02/20/2024FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER - INTERIOR COLLAPSE FROM THE ROOF LEVEL TO THE CELLAR LEVEL. EXTERIOR WALL SHOWS OUTWARD DEFLECTION. FULL VACATE TO PREMESIS ALONG WITH ENGINEER'S REPORT REQUIRED
DOB09/02/2020FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB09/02/2020FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB03/18/2020FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. NOTE: AT TIME OF INSPECTION OBSERVED AT EXP#/FRONT STAIRWAY LEADING TO 1ST FL LEVEL IS IN DISREPAIR. THE BRICK & ,ASONRY STAIRWAY HAS SEVERAL CRACKS,POROUS AREAS$25K due
DOB02/05/2020FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB01/04/2020FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. NOTE: AT TIME OF INSPECTION OBSERVED AT EXP#1 STAIRWAY LEADING TO 1ST FL LEVEL IS IN DISREPAIR. THE BRICK & MASONRY STAIRWAY HAS SEVERAL CRACKS,POROUS AREA,MISSI$25K due
DOB12/11/2019FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB12/11/2019FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB11/15/2019FAILURE TO MAINTAIN BLDG WALLS & APPURTENANCES AT FRONT STAIRS TO ENTRY DOOR CRACKED,LOOSE MISSING & BULGING. REMEDY: REPAIR OR REPLACE.$12K due
DOB10/17/2019FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB09/19/2019FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB09/16/2019FAILURE TO MAINTAIN BUILDING WALLS AND OR APPURTANCES AT FRONT STAIRS OF HOME BRICKS BUILDING,STEP CRACK,LOOSE MORTAR.REMEDY:REPAIR,REPLACE,MAKE SAFE.$12K due
ECB09/11/2019FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER NOTED AT TIME OF INPSETCION I OBSERVED AT EXPOSURE #1 FRONT ENTRNACE EXTERIOR STAIRS IN A STATE OF DISREPAIR WITH HOLES AND CRACKS THROUGHOUT AT ROOF LEVLE$12K due
DOB08/22/2019FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB07/18/2019FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES- @ FRONT STAIRS OF HOME. BRICKS BUILDING OUTWARD. STEP CRACKS. LOOSE MOTAR. STAIRS NOT IN GOOD SHAPE. REMEDY: MAINTAIN BUILDING WALLS.$25K due
DOB06/26/2019FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB06/20/2019FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. EXTERIOR STAIRS IN A STATE OF DISREPAIR WITH HOLES AND CRACKS THROUGHOUT. AT ROOF LEVEL THE SIDING IS MISSING IN MULTIPLE AREAS EXPOSING BRICK UNDERNEATH.$6K due
ECB06/01/2019FAILURE TO MAINTAIN BUILDING WALLS & APPURTENANCES @FRONT OF HOME(INSONRY) STAIRS CRACKED, BROKEN AND PULLING APART.REM: COMPLY WITH CODE.$12K due
ECB03/20/2019FAILURE TO MAINTAIN BUILDING WALL(S) APPURTENANCES NOTED:@TIME OF INSPECTION I OBSERVED FRONT OF BUILDING MASONRY STAIRS BROKEN AND CRACK INVARIOUS LOCATIONS AND PULLING AWAY MASONERY STAIRS MISSING 7 IN STATE$12K due
DOB03/06/2019FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB01/09/2019FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB12/07/2018FAILURE TO MAINTAIN BUILDING WALLS AND APPURTENANCES AT FRONT BUILDINGBEING MASONRY STAIRS MASONRY BRICKS MISSING IN STATE OF DISREPAIR AHDNING CONCRETE BREAKING.REM:REPAIR THE ROOF MAINTAIN EXTERIOR BUILDING W$12K due
DOB11/28/2018FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB10/31/2018FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB10/10/2018FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCE. AT THE TIME OF INSPECTION & OBSERVED AT EXP#1 FRONT BLDG BRICKS/MASONRY PLATFORM STAIRS ON 2ND LANDING CAPING EDGE IS LANDING MISSING CONCRETE SLAB,STEP ARE SEPER$25K due
ECB09/08/2018FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES-AT FRONT OF BLDG MASONARY STAIRS PLATFORM ARE SEPERATED FROM THE BRICK WORK. BRICK ARE BUDGING OUTWARD @ EXP#4. ALSO MORTAR IS MISSING AT VARIOUS AREAS ON THE STA$25K due
DOB09/05/2018FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB09/05/2018FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB08/04/2018FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES.NOTED:AT FRONT OF BUILDING MASONARY STAIRS PLATFORM HAS A HOLE 12LX8W AND SOME STEPS SEPERATING AND BRICKS FALLING OUT.REM:MAINTAIN EXTERIOR BUILDING WALLS$25K due
ECB06/09/2018FAILURE TO MAINTAIN BLDG WALL OR APPURTENANCES. NOTED: AT FRONT OF BLDG MASONRY AND BRICK STAIRS IS IN DISREPAIR SUCH AS A LARGE HOLE IN STAIRS PLATFORM APPRX 12"L X 8"W, LARGE CRACKS AT VARIOUS LOCATION,BRICKS$12K due
ECB06/09/2018FAILURE TO MAINTAIN BUILDING WALL OR APPURTENANCES. NOTE: AT FRONT OF BLDG MASONRY AND BRICK STAIRS IS IN DISREPAIR SUCH AS LARGE HOLD IN STAIRS PLATFORM APPRX 12"L X 8"W. LARGECRACKS AT VARIOUS LOCATIONS,BRICK$12K due
ECB07/11/2023UPON INSPECTION OBSERVED AT EXP.1/FRONT, MASONRY STAIRWAY THAT LEAD TO 1ST FLR HAS SEVERAL CRACKS AND MANY BRICKS THAT ARE OUT OF PLUMB.Nothing owed — awaiting certificate of correction