← Back
One story retail building
2801 WHITE PLAINS ROAD
BRONX · BIN 2053549
💬 Discuss this project
1950Year Built
1Stories
K1Building Class
R6Zoning
7,035 sfGross Floor Area
5Units
2 Open Violations ▸
One story retail building · Owner of record: 2801-2813 WHITE PLAI · 10,500 sf lot · 0.67 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Permit Issued — active, not yet Signed-off
Roof1p · 1 filing · 5 docs
Floor 1Under Construction4p · 3 filings · 16 docs
CellarUnder Construction5p · 2 filings · 11 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ANM CONSTRUCTION1309/13/2026
2801-2813 WHITE PLA 1103/22/2026
LORDAE REALTY203/22/2026
LORDAC REALTY CORPORATION103/22/2026
LORDAE PROPERTY MANAGEMENT103/21/2026
LORDAE MANAGEMENT203/21/2026
2801-2813 WHITE PLAINS RD103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BL CONSULTANT307/02/2026
ASHRAF CORP101/31/2025
KENNETH KOONS, ARCHITECTS206/18/2021
GINO O. LONGO, ARCHITECT103/04/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUPERIOR FIRE CONTROL103/21/2026
PROFESSIONAL SOLUTIONS203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ANM CONSTRUCTION CORPGeneral Contractor304/08/2026
SIGNORE & SONS PLBG CORPPlumbing207/08/2026
TIMOTHY COLEMANElectrical203/21/2026
L&J PLG & HTG CO OF NY INPlumbing107/08/2026
JOE MIDDLETONElectrical103/21/2026
TAP PLUMBING CORPPlumbing103/22/2026
TIMOTHY COLEMAN LICENSEDElectrical103/22/2026
SUPERIOR FIRE CONTROL INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JAY KAVI CORPORATION8500101/31/2025
KENNETH KOONS, ARCHITECTS1548206/18/2021
Building Lifecycle
All (46)Filed (7)Permit Issued (6)Violation (23)Inspection (5)Objection (2)Special Inspection (3)
07/02/2026
Filed — Alteration
INSTALLATION OF GAS FOR COMMERCIAL COOKING EQUIPMENT AND PLUMBING FIXTURES FOR A RESTAURANT, NEW ANSUL VALVE, NEW GAS METER. FIRE SUPPRESSION UNDER SEPARATE APPLICATION , NO CHANGE IN USE OCCUPANCY OR EGREES UNDER THIS APPLICATION.
X01087919-P1
03/26/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/27/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
02/27/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/23/2026
Permit issued — Plumbing
X01087919-S1-PL
01/17/2026
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/09/2026
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/14/2025
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
10/31/2025
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
10/22/2025
Permit issued — Plumbing
X01087919-S1-PL
02/04/2025
Permit issued — Mechanical Systems
X01174112-I1-MS
01/31/2025
Filed — Alteration
Filing to install Restaurant Kitchen hood and ductwork as per plans. No change in use, egress, or occupancy.
X01174112-I1
01/30/2025
Special inspection requirement — Mechanical Systems
Jay Kavi
01/30/2025
Special inspection requirement — Final
Eric Foster
10/09/2024
Permit issued — General Construction
X01087919-I1-GC
09/30/2024
Permit issued — Plumbing
X01087919-S1-PL
08/20/2024
Permit issued — General Construction
X01087919-I1-GC
08/16/2024
Filed — Alteration
INSTALLATION OF GAS FOR COMMERCIAL COOKING EQUIPMENT AND PLUMBING FIXTURES FOR A RESTAURANT, NEW ANSUL VALVE, NEW GAS METER. FIRE SUPPRESSION UNDER SEPARATE APPLICATION , NO CHANGE IN USE OCCUPANCY OR EGREES UNDER THIS APPLICATION.
X01087919-S1
08/14/2024
Filed — Alteration
INSTALLATION OF GAS FOR COMMERCIAL COOKING EQUIPMENT AND PLUMBING FIXTURES FOR A RESTAURANT, NEW ANSUL VALVE, NEW GAS METER. FIRE SUPPRESSION UNDER SEPARATE APPLICATION , NO CHANGE IN USE OCCUPANCY OR EGREES UNDER THIS APPLICATION.
X01087919-I1
07/29/2024
Special inspection requirement — Final
BALDEMIRO LEON
06/18/2021
Filed — Alteration
X00539115-I1
06/18/2021
Filed — Alteration
NEW NON BEARING PARTITIONS
X00539113-I1
03/10/2020
Objection raised — Admin
03/10/2020
Objection resolved — Addressed
03/04/2020
Filed — Alteration
FILING FOR INTERIOR RENOVATION OF EXISTING COMMERCIAL SPACE. NO CHANGE IN OCCUPANCY USE OR EGRESS.
X00316007-I1
05/02/2015
Violation issued (ECB, closed)
Construction
01/03/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/19/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/06/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/31/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/13/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/12/2003
Violation issued (ECB, closed)
Construction
03/19/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/26/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/27/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/07/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/16/1999
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/11/1999
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/04/1998
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/16/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/10/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/17/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/01/1992
Violation issued (DOB, closed)
VP*-VIOLATION UNSERVED ECB- DISMISSED
09/04/1991
Violation issued (ECB, closed)
Construction
09/04/1991
Violation issued (DOB, open)
VW-VIOLATION WORK WITHOUT PERMIT - ACTIVE
04/04/1990
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedL&J PLG & HTG CO OF NY IN01/23/2026
DOB NOWPlumbingPermit IssuedSIGNORE & SONS PLBG CORP10/22/2025
DOB NOWMechanical SystemsPermit IssuedSUPERIOR FIRE CONTROL INC02/04/2025
DOB NOWGeneral ConstructionPermit IssuedANM CONSTRUCTION10/09/2024
DOB NOWPlumbingPermit IssuedSIGNORE & SONS PLBG CORP09/30/2024
DOB NOWGeneral ConstructionPermit IssuedANM CONSTRUCTION08/20/2024
BISFPISSUEDMASTER FIRE SYSTEMS, INC08/09/2001
BISPLISSUEDNEPTUNE MECHANICAL INC11/15/2000
BISMHISSUEDMUNICIPAL BUILDING CONSULTANTS11/09/2000
BISPLISSUEDFIN TRIO PLUMBING07/24/1998
BISFPISSUEDMASTER FIRE SYSTEMS, INC07/23/1998
BISPLISSUEDMURRAY ROSENNBLUM04/30/1990
BISOTISSUEDRENEWAL ARTS CONTRACTING CO.03/13/1990
1 job · most recent 01/31/2025
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
01/31/2025Permit IssuedSUPERIOR FIRE CONTROL INCVentilation Systems
Ventilation
Pen Vent USBI18DD 4,500 CFM · Kitchen Exhaust ×1
2 jobs · most recent 07/02/2026
Water/Sanitary Gas
FiledStatusContractorScope
07/02/2026Permit IssuedL&J PLG & HTG CO OF NY INGas, Water/Sanitary
03/04/2020——Water/Sanitary
2 jobs · most recent 10/20/2025
General Wiring
FiledStatusContractorScope
10/20/2025Permit IssuedTIMOTHY COLEMAN LICENSED4 meters, 4 new_meters
07/21/2025Permit IssuedTIMOTHY COLEMAN LICENSEDGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
03/26/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/27/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
02/27/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/14/2025Fail-Final PL - Up to 3 Requested FloorsFailView ↗
10/31/2025Fail-Final PL - Up to 3 Requested FloorsFailView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
01/30/2025Mechanical SystemsJay Kavispecial
01/30/2025FinalEric Fosterprogress
07/29/2024FinalBALDEMIRO LEONprogress
▾Documents — 29 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch6
08/25/2026X00539115-I1Request digital key ↗
08/25/2026X00539113-I1Request digital key ↗
08/21/2026X01087919-P1Request digital key ↗
Showing 3 of 6 on file for this type
▸DOB NOWPlans/Sketch - Plumbing1
08/15/2026X00316007-I1Request digital key ↗
▸Applications & Permits1
▸BISPLAN / WORK APPROVAL APPLICATION1
02/25/2020220722378Open ↗
▸Seals & Professional Certifications11
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/25/2026X00539113-I1Open ↗
08/21/2026X01087919-P1Open ↗
08/13/2026X01174112-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
08/31/2026X01174112-I1Open ↗
08/23/2026X01087919-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
02/25/2020220722378Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/31/2026X01174112-I1Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/25/2026X00539113-I1Open ↗
08/13/2026X01174112-I1Open ↗
08/13/2026X01087919-I1Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
02/25/2020220722378Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
02/25/2020220722378Open ↗
▸Approvals, Objections & Sign-offs1
▸BISLETTERS - SUPPORTING DOCUMENTATION1
04/06/2020220722378Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
02/25/2020220722378Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
02/25/2020220722378Open ↗