← Back
One story - permanent living quarter
2930 COLDEN AVENUE
BRONX · BIN 2054974
💬 Discuss this project
1940Year Built
1Stories
A2Building Class
R5Zoning
1,490 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
One story - permanent living quarter · 5,000 sf lot · 0.3 FAR built · Flood zone X
Locations of Work
Electrical
Roof3p · 1 filing · 5 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PARKER AND WEST ENGINEERING, PLLC108/04/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SUNRUN INSTALLATION SVCGeneral Contractor108/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PARKER AND WEST ENGINEERI5272108/04/2026
Building Lifecycle
All (9)Filed (1)Permit Issued (1)Violation (2)Special Inspection (5)
08/07/2026
Permit issued — Solar
X01440051-I1-SL
08/04/2026
Filed — Alteration
FILING HEREWITH TAX ABATEMENT APPLICATION FOR INSTALLATION OF ROOF MOUNTED SOLAR PANELS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
X01440051-I1
08/04/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Walid Abdulla
08/04/2026
Special inspection requirement — Air barrier - visual inspection
Walid Abdulla
08/03/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Walid Abdulla
08/03/2026
Special inspection requirement — Energy Code Compliance Inspections
Walid Abdulla
08/03/2026
Special inspection requirement — Final
Walid Abdulla
01/06/2010
Violation issued (ECB, closed)
Construction
09/20/2006
Violation issued (ECB, closed)
Zoning
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedSUNRUN INSTALLATION SVC08/07/2026
1 project · most recent 08/04/2026
FiledStatusContractorScope
08/04/2026Permit IssuedSUNRUN SOLAR ELECTL CORP—
1 project · most recent 08/04/2026
FiledStatusContractorScope
08/04/2026Permit IssuedSUNRUN INSTALLATION SVC32 panels, 14.4 kw, 336 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
08/04/2026Structural Stability – Alterations of existing buildingsWalid Abdullaspecial
08/04/2026Air barrier - visual inspectionWalid Abdullaenergy_progress
08/03/2026Fire-Resistant Penetrations and JointsWalid Abdullaspecial
08/03/2026Energy Code Compliance InspectionsWalid Abdullaprogress
08/03/2026FinalWalid Abdullaprogress
▾Documents — 5 on file (BIS + DOB NOW)
▸Seals & Professional Certifications5
▸DOB NOWProgress Inspector Seal & Signature3
08/28/2026X01440051-I1Open ↗
08/28/2026X01440051-I1Open ↗
08/28/2026X01440051-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/28/2026X01440051-I1Open ↗
08/28/2026X01440051-I1Open ↗