ECB02/13/2026UNLAWFUL ACTS. FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER. AT TIME OF INSPECTION, OBSERVED THE RETAINING WALL REMAINS IN A DETERIORATED CONDITION. RESPONDENT FAILED TO COMPLY WITH FEU ORDERS TO REPAIR THE$12K due
ECB02/13/2026FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. AT TIME OF INSPECTION, OBSERVED THE CEILING IN A DETERIORATED CONDITION, WITH DAMAGED AND SAGGING MATERIALS CREATING AN UNSAFE CONDITION FOR OCCUPANTS. R$6K due
ECB02/13/2026FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIME OF INSPECTION, NO COFC ON FILE. RECORDS INDICATE JOB PERMITTED AND SIGNED OFF UNDER$6K due
DOB03/26/2024FTM.DUE TO PARTIAL COLLAPSE@NEIGHBORNG 4712 REAR WHITE PLAINS ROAD, OBSRVD DAMAGED BRICK MASONRY BEARNG WALL@EXPOSURE 3/4 CORNER.COMPLY WITH COMMISSIONER'S ORDER:DOB VIOLATION #030524FEU21205AK
DOB03/05/2024FTM.DUE TO PARTIAL COLLAPSE@NEIGHBORNG 4712 REAR WHITE PLAINS ROAD, OBSRVD DAMAGE BRICK MASONRY BEARNG WALL@EXPOSYRE 3/4 CORNER.COMPLY WITH COMMISSIONER'S ORDER:DOB VIOLATION #030524FEU21205AK
DOB10/24/2022FAILURE TO SUBMIT AN ACCEPTABLE INSPECTN RPT FOR STRUCTURALLY COMPROMISED BLDG.
DOB07/19/2022FAIL TO MAINTAIN BLDG-@FRONT EXP@SIDEWLK HATCH,A COLUMN SUPPRTNG ROOF FRAMNG& PARPT UNSUPPRTD.SUPPRTNG STEEL LINTL SEVRLY CORRDED &NO LONGER PROVDNG SUPPRT.FLOODED CELLR.ROTTN BEARNG ENDS 1FL JOISTS.OPNING @ROOF DUE TO FIRE & FF OPS.OWNR RTAIN NYS-LIC PE& CNTRCTR-EVAL ENTIRE BLDG & RPR UNDER PRMT.FILE RPRS BY 9/1/22.STRT WRK BY 10/1/22.CMPLT BY 5/1/23
DOB07/19/2022EMRGCY WORK-@FRNT EXP@SIDEWLK HATCH A COLUMN SUPPRTNG ROOFFRAMNG &BRCK PARAPT UNSUPPRTD &APPEARD DISPLCD DOWNWRD.SUPPRTNG STEEL LINTL SEVRLY CORRODED &NO PROVIDED SUPPRT.DIAGONAL CRCKNG OF PARAPT OWNR IMMED RTAIN NYS-LIC PE& CNTRCTR-DSGN &INSTLL SHORNG OF UNSUPPRTD COLUMN & STRCTRL ELEMNT NECESSRY.WRK STRT 7/22/22
ECB11/12/2021FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.NOTED CELLAR SPACES CONCERNING 4712 AND 4714 WHITE PLAINS ROAD HAVING DEFECTIVE,LOOSE CMU WALL TO DIVIDE CELLAR SPACE WITH MISSING,LOOSE AND DECREPT CONDI$6K due
DOB02/10/1997V-DOB VIOLATION - ACTIVE
DOB11/13/1990V-DOB VIOLATION - ACTIVE
ECB08/14/2024WORK WITHOUT A PERMIT. I OBSERVED NEW CONCRETE BLOCK EXTERIOR WALLS ERECTED WITH NO ACTIVE PERMIT. FACADE APPLICATION #X00783633 WAS APPROVED, HOWEVER NOT PERMITTED AT THIS TIME, OBTAIN ALL PERMITS; SUBMIT THENothing owed — awaiting certificate of correction
ECB08/14/2024JOB SITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBSECTION. I OBSERVED A CONSTRUCTION FENCE ERECTED WITH NO PERMIT. FENCE APPLICATION #X00783634 WAS APPROVED, HOWEVER IT WAS NOT PERMITTED AT THIS TIME,Nothing owed — awaiting certificate of correction
ECB03/04/2024NOTED AT A SEMI DETACHED REAR GARAGE LOCATED IN ALLEY THAT APROX 8 FT OF CMU WALL HAS COLLAPSED AT EXP 2 LEAVING REAR EXP 3 WALL UNSUPPORTED., REPAIR AND/REPLACE; SUPPORT REAR WALL.Nothing owed — awaiting certificate of correction
ECB10/18/2006FAILURE TO MAINTAIN. WOOD STAIR CASE LEADING FORM 1ST FL TO BASEMENT ROTTED & DEFECTIVE. (NOTE)STAIR CASE IS ILLEGAL AS PER VIO #34540239K 101806C12FG07.REMEDY"MAKE ALL NECESSARY REPAIRS OR REMOVE STAIRS.Nothing owed — awaiting certificate of correction
ECB10/18/2006WORK W/O PERMITS. HAVING CUT 4 FL JOISTS AT 1ST FL TO CREATE OPENING TO BASEMENT:INSTALLED WOOD STAIRS. REMEDY:OBTAIN ALL NECESSARY PERMITS OR RESTORE TO PRIOR LEGAL CONDITION.Nothing owed — awaiting certificate of correction
ECB10/18/2006FAILURE TO MAINTAIN. 5 3 X 12 WOOD FLOOR JOISTS ROTTED & DEFECTIVE. 1 2 X 12 WOOD(HEADER)FLOOR JOISTS ARE ATTACHED TO IS ROTTED & DEFECTIVE.CAUSING REAR OF 1ST FL TO BECOME UNSTABLE. REMEDY:MAKE ALL NECESSARYNothing owed — awaiting certificate of correction