← Back
Two family frame
820 PENFIELD STREET
BRONX · BIN 2072010
💬 Discuss this project
1925Year Built
2Stories
B2Building Class
R4AZoning
2,124 sfGross Floor Area
2Units
1 Open Violation 0 unresolved · 1 paperwork only ▸
Two family frame · 2,621 sf lot · 0.81 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
1 job · most recent 09/20/2026
FiledStatusContractorScope
09/20/2026Permit IssuedESSENTIAL ELECTRICAL3 meters, 1 new_meters
Building Lifecycle
All (15)Filed (3)Permit Issued (1)Signed Off (2)Violation (3)Inspection (5)Special Inspection (1)
07/18/2022
Signed off — Alteration
X00485079-I1
07/12/2022
Signed off — Alteration
Repair fire/water damage to interior plumbing. Remove and cap lines for 3 piece bathroom in cellar; remove and cap line for kitchen sink in cellar; relocate existing boiler and hot water heater and replace gas piping.
X00529792-I1
02/11/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/10/2022
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
02/10/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/10/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/10/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
01/03/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
GABY TCHILINGUIRIAN
12/30/2021
Filed — Alteration
Repair fire/water damage to interior plumbing. Remove and cap lines for 3 piece bathroom in cellar; remove and cap line for kitchen sink in cellar; relocate existing boiler and hot water heater and replace gas piping.
X00529792-P1
11/01/2021
Permit issued — Plumbing
X00529792-I1-PL
10/26/2021
Filed — Alteration
Repair fire/water damage to interior plumbing. Remove and cap lines for 3 piece bathroom in cellar; remove and cap line for kitchen sink in cellar; relocate existing boiler and hot water heater and replace gas piping.
X00529792-I1
05/04/2021
Filed — Alteration
X00485079-I1
06/21/2001
Violation issued (ECB, open)
HPD
04/26/2001
Violation issued (HPD, closed)
B
04/26/2001
Violation issued (HPD, closed)
B
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MIGLIORE RESTORATION INC.,903/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
GABY TCHILINGUIRIAN R.A.312/30/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
LAW OFFICE OF REBECCA WENNER303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DPH PLUMBING & HTG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GABY TCHILINGUIRIAN R.A.2540312/30/2021
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offDPH PLUMBING & HTG CORP11/01/2021
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
02/11/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/10/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
02/10/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/10/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/10/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 1
DateRequirementInspectorRole
01/03/2022Fire-Resistant Penetrations and JointsGABY TCHILINGUIRIANspecial
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/25/2026X00485079-I1Request digital key ↗
08/24/2026X00529792-P1Request digital key ↗
08/24/2026X00529792-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/24/2026X00529792-I1Open ↗
08/24/2026X00529792-P1Open ↗
08/13/2026X00485079-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/23/2026X00529792-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/24/2026X00529792-P1Open ↗
08/24/2026X00529792-I1Open ↗
08/13/2026X00485079-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026X00485079-I1Open ↗