← Back
Two family frame
4517 SETON AVENUE
BRONX · BIN 2072225
💬 Discuss this project
1920Year Built
2Stories
B2Building Class
R4AZoning
1,280 sfGross Floor Area
2Units
2 Open Violations ▸
Two family frame · 2,625 sf lot · 0.49 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 21p · 1 filing · 5 docs
Floor 1
Basement2p · 1 filing · 8 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
THOMAS J. CURRO ARCHITECT, PC311/04/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
M. MARIN RESTORATION INCGeneral Contractor107/08/2026
WATERMARK PLUMBING CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS J. CURRO ARCHITECT718311/04/2024
Building Lifecycle
All (17)Filed (3)Permit Issued (2)Signed Off (2)Violation (2)Inspection (4)Special Inspection (4)
02/06/2025
Signed off — Alteration
Plumbing work related to the repairs to fire damaged 2 family residence at cellar, 1st and 2nd floors. No change in use, egress or occupancy. General Construction work filed under DOBNOW job X00990504.
X00992164-I1
02/06/2025
Signed off — Alteration
General Construction work filed for the repairs of fire damaged 2 family residence. Plumbing work filed under DOBNOW job X00992164-I1. No change in use, egress or occupancy.
X00990504-I1
11/29/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
11/14/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
11/14/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/14/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
11/07/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
THOMAS CURRO
11/07/2024
Special inspection requirement — Energy Code Compliance Inspections
THOMAS CURRO
11/04/2024
Filed — Alteration
Plumbing work related to the repairs to fire damaged 2 family residence at cellar, 1st and 2nd floors. No change in use, egress or occupancy. General Construction work filed under DOBNOW job X00990504.
X00992164-P1
04/02/2024
Permit issued — Plumbing
X00992164-I1-PL
02/22/2024
Permit issued — General Construction
X00990504-I1-GC
02/21/2024
Filed — Alteration
Plumbing work related to the repairs to fire damaged 2 family residence at cellar, 1st and 2nd floors. No change in use, egress or occupancy. General Construction work filed under DOBNOW job X00990504.
X00992164-I1
02/16/2024
Filed — Alteration
General Construction work filed for the repairs of fire damaged 2 family residence. Plumbing work filed under DOBNOW job X00992164-I1. No change in use, egress or occupancy.
X00990504-I1
01/15/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
THOMAS CURRO
01/15/2024
Special inspection requirement — Final
THOMAS CURRO
07/15/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
05/14/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offWATERMARK PLUMBING CORP04/02/2024
DOB NOWGeneral ConstructionSigned-offM. MARIN RESTORATION INC02/22/2024
1 project · most recent 03/24/2024
General Wiring
FiledStatusContractorScope
03/24/2024Permit IssuedV. VASS ELECTRIC CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
11/29/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/14/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
11/14/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/14/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
11/07/2024Fire-Resistant Penetrations and JointsTHOMAS CURROspecial
11/07/2024Energy Code Compliance InspectionsTHOMAS CURROprogress
01/15/2024Fire-Resistant Penetrations and JointsTHOMAS CURROspecial
01/15/2024FinalTHOMAS CURROprogress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/21/2026X00990504-I1Request digital key ↗
08/21/2026X00992164-P1Request digital key ↗
08/21/2026X00992164-I1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/21/2026X00992164-I1Open ↗
08/13/2026X00990504-I1Open ↗
08/13/2026X00992164-P1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026X00990504-I1Open ↗
08/24/2026X00992164-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026X00990504-I1Open ↗
08/24/2026X00992164-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/21/2026X00992164-I1Open ↗
08/13/2026X00992164-P1Open ↗
08/13/2026X00990504-I1Open ↗