← Back
Office with apartments (no commercial)
3853 EAST TREMONT AVENUE
BRONX · BIN 2077136
💬 Discuss this project
1966Year Built
2Stories
O8Building Class
R3AZoning
11,666 sfGross Floor Area
7Units
Office with apartments (no commercial) · Owner of record: GMIM3853 LLC · 12,600 sf lot · 0.93 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ANSANO CONSTRUCTION809/13/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
DENNIS V. PANETTIERI, ARCHITECT405/17/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ALBA CONSULTANTS403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BLUSHI CONSTRUCTION INCGeneral Contractor104/09/2026
DONATO PLUMBING, INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MASTROGIACOMO ENGINEERING4237211/30/2025
Building Lifecycle
All (15)Filed (4)Permit Issued (2)Signed Off (2)Inspection (4)Special Inspection (3)
05/20/2026
Signed off — Alteration
NYC dob now build alteration application filed to renovate existing first floor office partitions and install new handicapped accessory toilet room separate does now application be filed for plumbing work to be performed in conjuctionwith this
X01324987-S1
05/20/2026
Signed off — Alteration
NYC dob now build alteration application filed to renovate existing first floor office partitions and install new handicapped accessory toilet room separate does now application be filed for plumbing work to be performed in conjuctionwith this
X01324987-I1
05/19/2026
Special inspection requirement — Tenant Protection Plan Compliance
MICHAEL MASTROGIACOMO
05/19/2026
Special inspection requirement — Final
MICHAEL MASTROGIACOMO
05/17/2026
Filed — Alteration
NYC dob now build alteration application filed to renovate existing first floor office partitions and install new handicapped accessory toilet room separate does now application be filed for plumbing work to be performed in conjuctionwith this
X01324987-P2
05/17/2026
Filed — Alteration
NYC dob now build alteration application filed to renovate existing first floor office partitions and install new handicapped accessory toilet room separate does now application be filed for plumbing work to be performed in conjuctionwith this
X01324987-P1
05/13/2026
Special inspection requirement — Tenant Protection Plan Compliance
04/30/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/30/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/13/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/13/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
02/05/2026
Permit issued — Plumbing
X01324987-S1-PL
12/29/2025
Permit issued — General Construction
X01324987-I1-GC
11/30/2025
Filed — Alteration
NYC dob now build alteration application filed to renovate existing first floor office partitions and install new handicapped accessory toilet room separate does now application be filed for plumbing work to be performed in conjuctionwith this
X01324987-S1
11/30/2025
Filed — Alteration
NYC dob now build alteration application filed to renovate existing first floor office partitions and install new handicapped accessory toilet room separate does now application be filed for plumbing work to be performed in conjuctionwith this
X01324987-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offDONATO PLUMBING, INC02/05/2026
DOB NOWGeneral ConstructionSigned-offBLUSHI CONSTRUCTION INC12/29/2025
1 project · most recent 03/05/2026
General Wiring
FiledStatusContractorScope
03/05/2026CompleteP & Z ELECTRIC CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
04/30/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
04/30/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/13/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/13/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
05/19/2026Tenant Protection Plan ComplianceMICHAEL MASTROGIACOMOspecial
05/19/2026FinalMICHAEL MASTROGIACOMOprogress
05/13/2026Tenant Protection Plan Compliance—special
▾Documents — 14 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/17/2026X01324987-P1Request digital key ↗
08/17/2026X01324987-P2Request digital key ↗
08/17/2026X01324987-S1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/17/2026X01324987-P2Open ↗
08/17/2026X01324987-S1Open ↗
08/17/2026X01324987-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature1
08/31/2026X01324987-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/31/2026X01324987-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/17/2026X01324987-P2Open ↗
08/17/2026X01324987-S1Open ↗
08/17/2026X01324987-P1Open ↗
Showing 3 of 4 on file for this type