| Owner | Filings | Most Recent |
|---|---|---|
| LOFT CONTRACTING NEW YORK | 7 | 07/08/2026 |
| BRINSMADE AVE LLC C/O LOA | 2 | 03/22/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| H G LEE ARCHITECT PC | 3 | 10/07/2025 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| LOFT CONTRACTING NEW YORK | General Contractor | 2 | 07/08/2026 |
| JUST PLBG & HTG INC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| HG LEE ARCHITECT PC | 2554 | 2 | 10/07/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Permit Issued | MOHAMED ABDELRAZEK | 12/09/2025 |
| DOB NOW | Mechanical Systems | Permit Issued | LOFT CONTRACTING NEW YORK | 11/26/2025 |
| DOB NOW | General Construction | Permit Issued | LOFT CONTRACTING NEW YORK | 11/25/2025 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 10/07/2025 | Permit Issued | LOFT CONTRACTING NEW YORK | Air Conditioning Systems | Cooling — model name: 30,000 BTU Tri-Zone Mini Split Air Conditioner - Heat Pump Model number: GWHD(30)ND6MO 30,000 BTU · Heat Pump Outdoor ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/07/2025 | Permit Issued | JUST PLBG & HTG INC | Gas, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/19/2026 | Permit Issued | TITANIUM ELECTRICAL CORP | General Wiring |
| Date | Type | Result | Report |
|---|---|---|---|
| 03/03/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 03/03/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 02/26/2026 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 06/18/2025 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 06/06/2025 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 12/01/2023 | Fail-Final PL - More than 10 Requested Floors | Fail | View ↗ |
| 11/09/2023 | Fail-Final PL - More than 10 Requested Floors | Fail | View ↗ |
| 09/08/2022 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 04/29/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 04/26/2022 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 09/29/2025 | HVAC-R and service water piping design and insulation | He Gin Lee | energy_progress |
| 09/29/2025 | HVAC-R and service water heating system controls | He Gin Lee | energy_progress |
| 09/29/2025 | HVAC-R and service water heating equipment | He Gin Lee | energy_progress |
| 09/25/2025 | Mechanical Systems | He Gin Lee | special |
| 09/25/2025 | Final | He Gin Lee | progress |