← Back
Two family brick
3631 GREYSTONE AVENUE
BRONX · BIN 2083986
💬 Discuss this project
1920Year Built
2Stories
B1Building Class
R6Zoning
2,212 sfGross Floor Area
2Units
Two family brick · 2,500 sf lot · 0.88 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
CI CONTRACTING407/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ENTHINK ENGINEERS LLC103/31/2023
LEDER-LUIS ARCHITECTURAL DESIGN, PL210/11/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
XPDITE GROUP LLC (104)203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ANDAMIO SCAFFOLDING LLCGeneral Contractor107/08/2026
Building Lifecycle
All (40)Filed (3)Permit Issued (1)Signed Off (1)Objection (28)Special Inspection (7)
07/07/2023
Signed off — Alteration
X00850478-I1
04/03/2023
Permit issued — Supported Scaffold
X00850478-I1-SF
03/31/2023
Filed — Alteration
X00850478-I1
11/25/2022
Special inspection requirement — Insulation placement and R values
11/25/2022
Special inspection requirement — Air barrier - visual inspection
11/04/2022
Special inspection requirement — Post-installed Anchors
10/13/2022
Objection raised — 2014-SFBC 3314.4.3.3-Code requ
10/13/2022
Objection resolved — Addressed
10/13/2022
Objection raised — 2014-SFBC 1704.20.1 -Special I
10/13/2022
Objection resolved — Addressed
10/13/2022
Objection raised — 2014-SFBC 1704.32, Table 1704.
10/13/2022
Objection resolved — Addressed
10/13/2022
Objection raised — 2014-SFBC 3314.3.4-Design-Buil
10/13/2022
Objection resolved — Addressed
10/13/2022
Objection raised — 2014-SFBC 3301.1- Scaffold Pla
10/13/2022
Objection resolved — Addressed
10/13/2022
Objection raised — 2014-SFBC 3314.8-Safety - Wire
10/13/2022
Objection resolved — Addressed
10/13/2022
Objection raised — 2014-SFBC 3314.4.4-Design load
10/13/2022
Objection resolved — Addressed
10/13/2022
Objection raised — 2014-SFBC 1704.14 -Special Ins
10/13/2022
Objection resolved — Addressed
10/11/2022
Filed — Alteration
Construction work for facade and parapet repair. No change in Egress, Use or Occupancy.
X00732961-S1
09/01/2022
Special inspection requirement — Masonry
09/01/2022
Special inspection requirement — Fire-Resistance Rated Construction
09/01/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
09/01/2022
Special inspection requirement — Energy Code Compliance Inspections
08/24/2022
Objection raised — Energy
08/24/2022
Objection resolved — Addressed
08/24/2022
Objection raised — Inspections
08/24/2022
Objection resolved — Addressed
06/14/2022
Objection raised — Other
06/14/2022
Objection resolved — Addressed
06/07/2022
Objection raised — Inspections
06/07/2022
Objection resolved — Addressed
06/07/2022
Objection raised — Other
06/07/2022
Objection resolved — Addressed
06/07/2022
Objection raised — Other
06/07/2022
Objection resolved — Addressed
06/02/2022
Filed — Alteration
Construction work for facade and parapet repair. No change in Egress, Use or Occupancy.
X00732961-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSupported ScaffoldSigned-offANDAMIO SCAFFOLDING LLC04/03/2023
BISOTISSUEDAMERICAN SOLAR PARTNERS,09/08/2017
1 project · most recent 01/18/2018
FiledStatusContractorScope
01/18/2018CancelledARCADIA ELECT'L CO. INC.—
1 project · most recent 10/11/2022
Scaffold
FiledStatusContractorScope
10/11/2022——Scaffold
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
11/25/2022Insulation placement and R values—energy_progress
11/25/2022Air barrier - visual inspection—energy_progress
11/04/2022Post-installed Anchors—special
09/01/2022Masonry—special
09/01/2022Fire-Resistance Rated Construction—progress
09/01/2022Structural Stability – Alterations of existing buildings—special
09/01/2022Energy Code Compliance Inspections—progress
▾Documents — 19 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/23/2026X00850478-I1Request digital key ↗
08/14/2026X00732961-S1Request digital key ↗
08/14/2026X00732961-I1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
07/18/2017240189069Open ↗
▸BISWORK PERMIT APPLICATION1
09/08/2017240189069Open ↗
▸Seals & Professional Certifications4
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/24/2026X00732961-S1Open ↗
08/24/2026X00732961-I1Open ↗
08/13/2026X00850478-I1Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
07/18/2017240189069Open ↗
▸Trade Schedules & Equipment1
▸BISFA - FDNY APPROVAL : FD-FAA1
07/18/2017240189069Open ↗
▸Safety & Tenant Protection1
▸BISTENANT PROTECTION PLAN AND NOTES1
07/18/2017240189069Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
07/18/2017240189069Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/14/2026X00732961-I1Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
07/18/2017240189069Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
07/18/2017240189069Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
07/18/2017240189069Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
07/18/2017240189069Open ↗
▸Filing & Intake Forms2
▸BISEFILING JOB APPLICATION COVER SHEET1
07/18/2017240189069Open ↗
▸BISADDITIONAL INFORMATION1
08/25/2017240189069Open ↗