← Back
Predominantly retail with other uses
881 EAST 134 STREET
BRONX · BIN 2094123
💬 Discuss this project
1931Year Built
2Stories
K4Building Class
M3-1Zoning
28,090 sfGross Floor Area
14Units
4 Open Violations 1 unresolved · 3 paperwork only ▸
Predominantly retail with other uses · Owner of record: MHT REALTY LLC · 29,960 sf lot · 0.94 FAR built · Flood zone X500
Locations of Work
No floor-level scope or drawing coverage on file for this building.
1 job · most recent 10/22/2025
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
10/22/2025——Ventilation Systems
Ventilation
Captiveaire dmua18fa 2,220 CFM · Makeup Air ×1
du240hfa 5,500 CFM · Kitchen Exhaust ×1
1 job · most recent 10/22/2025
Gas
FiledStatusContractorScope
10/22/2025Signed-offMASTER PLBG AND HTG INCGas
Building Lifecycle
All (10)Filed (2)Permit Issued (1)Special Inspection (7)
11/03/2025
Permit issued — Plumbing
X01211763-S1-PL
10/22/2025
Filed — Alteration
APPLICATION FILED TO INSTALL NEW HOOD, EXHAUST FAN, MAKE-UP AIRUNIT, AND ASSOCIATED DUCT AS PER PLAN AT FIRST FLOOR. NO CHANGE INBULK, FLOOR AREA, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.
X01211763-S1
10/22/2025
Special inspection requirement — Energy Code Compliance Inspections
SOHAIL HUMAYUN
10/22/2025
Special inspection requirement — HVAC-R and service water heating equipment
SOHAIL HUMAYUN
10/22/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
SOHAIL HUMAYUN
10/22/2025
Special inspection requirement — Maintenance information
SOHAIL HUMAYUN
10/22/2025
Special inspection requirement — HVAC-R and service water heating system controls
SOHAIL HUMAYUN
05/08/2025
Filed — Alteration
APPLICATION FILED TO INSTALL NEW HOOD, EXHAUST FAN, MAKE-UP AIRUNIT, AND ASSOCIATED DUCT AS PER PLAN AT FIRST FLOOR. NO CHANGE INBULK, FLOOR AREA, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.
X01211763-I1
04/16/2025
Special inspection requirement — Mechanical Systems
SOHAIL HUMAYUN
04/16/2025
Special inspection requirement — Final
SOHAIL HUMAYUN
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MHT REALTY LLC703/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SOHAIL HUMAYUN P E INC210/22/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MASTER 2 PLBG & HTG INCPlumbing106/27/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SOHAIL HUMAYUN P E INC8457105/08/2025
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offMASTER 2 PLBG & HTG INC11/03/2025
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
10/22/2025Energy Code Compliance InspectionsSOHAIL HUMAYUNprogress
10/22/2025HVAC-R and service water heating equipmentSOHAIL HUMAYUNenergy_progress
10/22/2025HVAC-R and service water piping design and insulationSOHAIL HUMAYUNenergy_progress
10/22/2025Maintenance informationSOHAIL HUMAYUNenergy_progress
10/22/2025HVAC-R and service water heating system controlsSOHAIL HUMAYUNenergy_progress
04/16/2025Mechanical SystemsSOHAIL HUMAYUNspecial
04/16/2025FinalSOHAIL HUMAYUNprogress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/19/2026X01211763-I1Request digital key ↗
08/19/2026X01211763-S1Request digital key ↗
▸Seals & Professional Certifications9
▸DOB NOWProgress Inspector Seal & Signature6
08/27/2026X01211763-I1Open ↗
08/23/2026X01211763-S1Open ↗
08/23/2026X01211763-S1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/19/2026X01211763-S1Open ↗
08/19/2026X01211763-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/27/2026X01211763-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/19/2026X01211763-S1Open ↗
08/19/2026X01211763-I1Open ↗