← Back
Three families
3025 LACONIA AVENUE
BRONX · BIN 2099207
💬 Discuss this project
1993Year Built
3Stories
C0Building Class
R5Zoning
3,448 sfGross Floor Area
3Units
Rent Stabilized2 Open Violations ▸
Three families · 3,670 sf lot · 0.94 FAR built · Flood zone X
Locations of Work
Architecture
Floor 312p · 1 filing · 20 docs
Floor 211p · 1 filing · 20 docs
Floor 112p · 1 filing · 20 docs
Cellar11p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
DENNIS DOUGLAS P.E., P.C101/13/2021
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TIMOTHY COLEMANElectrical303/21/2026
INIQUE WOODWORKING INCGeneral Contractor303/21/2026
TIMOTHY COLEMAN LICENSEDElectrical203/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DENNIS DOUGLAS, P.E., P.C7403101/13/2021
Building Lifecycle
All (23)Filed (1)Permit Issued (1)Violation (10)Special Inspection (11)
04/30/2026
Violation issued (HPD, open)
A
06/05/2025
Violation issued (HPD, open)
A
04/02/2024
Violation issued (HPD, closed)
A
11/16/2023
Violation issued (HPD, closed)
I
03/17/2023
Violation issued (HPD, closed)
A
11/04/2022
Violation issued (HPD, closed)
I
02/17/2022
Violation issued (HPD, closed)
A
04/02/2021
Violation issued (HPD, closed)
A
03/01/2021
Permit issued — General Construction
X00445846-I1-GC
01/13/2021
Filed — Alteration
PROPOSED REPAIRS TO FIRE DAMAGE BUILDING.
X00445846-I1
01/13/2021
Special inspection requirement — Interior lighting power
Dennis Douglas
01/13/2021
Special inspection requirement — Fenestration areas
Dennis Douglas
01/13/2021
Special inspection requirement — Fenestration and door U-factor and product ratings
Dennis Douglas
01/13/2021
Special inspection requirement — Fenestration air leakage
Dennis Douglas
01/13/2021
Special inspection requirement — Lighting controls
Dennis Douglas
01/02/2021
Special inspection requirement — Energy Code Compliance Inspections
Dennis Douglas
01/02/2021
Special inspection requirement — Sprayed fire-resistant materials
Dennis Douglas
01/02/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
Dennis Douglas
01/02/2021
Special inspection requirement — Energy Code Compliance
Dennis Douglas
01/02/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Dennis Douglas
12/31/2020
Special inspection requirement — Final
Dennis Douglas
10/31/2016
Violation issued (HPD, closed)
I
10/05/2015
Violation issued (HPD, closed)
I
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedINIQUE WOODWORKING INC03/01/2021
BISPLISSUEDNEW PLBG & HTG CORP07/23/1993
BIS—ISSUEDS. FRANCIOSA & SONS05/29/1992
BIS—ISSUEDS. FRANCIOSA & SONS05/23/1991
3 projects · most recent 09/04/2022
General Wiring
FiledStatusContractorScope
09/04/2022Permit IssuedTIMOTHY COLEMAN LICENSED4 meters, 1 new_meters
05/20/2022Permit IssuedTIMOTHY COLEMAN LICENSEDGeneral Wiring
05/12/2021CompleteTIMOTHY COLEMAN LICENSEDGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
01/13/2021Interior lighting powerDennis Douglasenergy_progress
01/13/2021Fenestration areasDennis Douglasenergy_progress
01/13/2021Fenestration and door U-factor and product ratingsDennis Douglasenergy_progress
01/13/2021Fenestration air leakageDennis Douglasenergy_progress
01/13/2021Lighting controlsDennis Douglasenergy_progress
01/02/2021Energy Code Compliance InspectionsDennis Douglasprogress
01/02/2021Sprayed fire-resistant materialsDennis Douglasspecial
01/02/2021Structural Stability – Alterations of existing buildingsDennis Douglasspecial
01/02/2021Energy Code ComplianceDennis Douglasprogress
01/02/2021Fire-Resistant Penetrations and JointsDennis Douglasspecial
12/31/2020FinalDennis Douglasprogress
▾Documents — 28 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch - General Construction2
08/25/2026X00445846-I1Request digital key ↗
08/25/2026X00445846-P1Request digital key ↗
▸Seals & Professional Certifications24
▸DOB NOWProgress Inspector Seal & Signature16
09/29/2026X00445846-I1Open ↗
09/29/2026X00445846-I1Open ↗
09/29/2026X00445846-I1Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/29/2026X00445846-I1Open ↗
09/29/2026X00445846-I1Open ↗
09/29/2026X00445846-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026X00445846-P1Open ↗
08/13/2026X00445846-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026X00445846-I1Open ↗
08/13/2026X00445846-P1Open ↗