← Back
Three families
1500 VYSE AVENUE
BRONX · BIN 2113153
💬 Discuss this project
2005Year Built
3Stories
C0Building Class
R7-1Zoning
3,678 sfGross Floor Area
3Units
Rent Stabilized40 Open Violations ▸
Three families · 2,083 sf lot · 1.77 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
1 job · most recent 02/12/2026
Sprinkler System
FiledStatusContractorScope
02/12/2026——Sprinkler System
1 job · most recent 02/12/2026
Storm Water/Sanitary
FiledStatusContractorScope
02/12/2026——Storm, Water/Sanitary
2 jobs · most recent 12/21/2025
General Wiring
FiledStatusContractorScope
12/21/2025Permit IssuedTIMOTHY COLEMAN LICENSED4 meters, 1 new_meters
02/23/2022CompleteHI-RITE ELECTRIC CORPGeneral Wiring
1 job · most recent 02/12/2026
Steel
FiledStatusContractorScope
02/12/2026——Steel
Building Lifecycle
All (119)Filed (5)Violation (60)Objection (37)Special Inspection (17)
05/08/2026
Violation issued (HPD, open)
A
05/07/2026
Objection resolved — Addressed
05/07/2026
Objection resolved — Addressed
04/20/2026
Objection resolved — Addressed
04/20/2026
Objection resolved — Addressed
04/20/2026
Objection resolved — Addressed
04/20/2026
Objection resolved — Addressed
04/20/2026
Objection resolved — Addressed
04/20/2026
Objection resolved — Addressed
04/13/2026
Objection resolved — Addressed
03/10/2026
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/05/2026
Objection resolved — Addressed
03/05/2026
Objection resolved — Addressed
03/05/2026
Objection resolved — Addressed
03/05/2026
Special inspection requirement — Smoke Control Systems Testing
03/04/2026
Objection raised — Other
03/03/2026
Objection raised — Admin
03/03/2026
Objection raised — Admin
03/03/2026
Objection raised — Structural
03/03/2026
Objection raised — Admin
03/03/2026
Objection raised — Admin
03/03/2026
Objection raised — Structural
02/25/2026
Objection resolved — Addressed
02/25/2026
Objection resolved — Addressed
02/25/2026
Objection resolved — Addressed
02/25/2026
Objection resolved — Addressed
02/25/2026
Objection resolved — Addressed
02/19/2026
Objection raised — Scope
02/19/2026
Objection raised — Admin
02/19/2026
Objection raised — Scope
02/19/2026
Objection raised — Structural
02/19/2026
Objection raised — Structural
02/18/2026
Objection raised — Admin
02/18/2026
Objection raised — Admin
02/18/2026
Objection raised — Admin
02/18/2026
Objection raised — Mechanical
02/12/2026
Filed — Alteration CO
HEREWITH FILING AN ALT 1 APPLICATION TO CONVERT THE PROPERTY FROM A 3-FAMILY TO AN 8-FAMILY DWELLING UNIT, WITH NO CHANGES TO THE USE, EGRESS, OR OCCUPANCY.
X01324122-S2
02/12/2026
Special inspection requirement — Structural Cold-Formed Steel
02/11/2026
Special inspection requirement — Structural Steel - High Strength Bolting
02/11/2026
Special inspection requirement — Structural Steel - Welding
02/11/2026
Special inspection requirement — Structural Steel - Details
02/05/2026
Filed — Alteration CO
HEREWITH FILING AN ALT 1 APPLICATION TO CONVERT THE PROPERTY FROM A 3-FAMILY TO AN 8-FAMILY DWELLING UNIT, WITH NO CHANGES TO THE USE, EGRESS, OR OCCUPANCY.
X01324122-S4
02/05/2026
Filed — Alteration CO
HEREWITH FILING AN ALT 1 APPLICATION TO CONVERT THE PROPERTY FROM A 3-FAMILY TO AN 8-FAMILY DWELLING UNIT, WITH NO CHANGES TO THE USE, EGRESS, OR OCCUPANCY.
X01324122-S3
02/05/2026
Filed — Alteration CO
HEREWITH FILING AN ALT 1 APPLICATION TO CONVERT THE PROPERTY FROM A 3-FAMILY TO AN 8-FAMILY DWELLING UNIT, WITH NO CHANGES TO THE USE, EGRESS, OR OCCUPANCY.
X01324122-S5
02/04/2026
Special inspection requirement — Final
02/04/2026
Special inspection requirement — Fire-Resistance Rated Construction
02/04/2026
Special inspection requirement — HVAC-R and service water heating equipment
02/04/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
02/04/2026
Special inspection requirement — HVAC-R and service water heating system controls
02/04/2026
Special inspection requirement — Sprinkler Systems
02/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
02/04/2026
Special inspection requirement — Mechanical Systems
02/04/2026
Special inspection requirement — Heating Systems
02/04/2026
Special inspection requirement — Post-installed Anchors
02/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
01/26/2026
Objection resolved — Addressed
12/24/2025
Objection raised — Fire_Protection
12/24/2025
Objection raised — Cost
12/24/2025
Objection raised — Scope
12/12/2025
Special inspection requirement — Final
Latest 60 of 119 events.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/09/2025$270K—— → —$73/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MOHAMMAD AHEAD, PE502/12/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EZFILINGNYCORP503/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TIMOTHY COLEMANElectrical103/21/2026
TIMOTHY COLEMAN LICENSEDElectrical103/22/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BIS—ISSUEDS & M PLUMBING & HEATING INC12/02/2005
BISEQISSUEDS & M PLUMBING & HEATING INC12/02/2005
BISPLISSUEDTHE PLUMBING COMPANY, INC09/29/2005
BIS—ISSUEDS & M PLUMBING & HEATING INC09/19/2005
BISEQISSUEDS & M PLUMBING & HEATING INC09/19/2005
▾Special Inspection Requirements (DOB NOW) — 17
DateRequirementInspectorRole
03/05/2026Smoke Control Systems Testing—special
02/12/2026Structural Cold-Formed Steel—special
02/11/2026Structural Steel - High Strength Bolting—special
02/11/2026Structural Steel - Welding—special
02/11/2026Structural Steel - Details—special
02/04/2026Final—progress
02/04/2026Fire-Resistance Rated Construction—progress
02/04/2026HVAC-R and service water heating equipment—energy_progress
02/04/2026HVAC-R and service water piping design and insulation—energy_progress
02/04/2026HVAC-R and service water heating system controls—energy_progress
02/04/2026Sprinkler Systems—special
02/04/2026Fire-Resistant Penetrations and Joints—special
02/04/2026Mechanical Systems—special
02/04/2026Heating Systems—special
02/04/2026Post-installed Anchors—special
02/04/2026Fire-Resistant Penetrations and Joints—special
12/12/2025Final—progress
Nothing on file for this building.